Electrical upgrades include a circuit for a pool heat pump
An electrical permit filed September 24, 2026, covers replacement of the existing main panel, an exterior outlet for a plug-in EV charger, and a 20-amp circuit for a Cowboy Pool heat pump. The permit says the existing 125-amp service will remain; it is not a service upgrade. The active permit is 2026-124056 EP.
Summarized from City of Austin records · updated Sep 24, 2026
- Projects
- 1
- 1 filings
- Latest filing
- Sep 24, 2026
- since Sep 24, 2026
- Largest scope
- —
- Listed value
- —
Permit & project history
1 projectTemporary disconnect required. replace existing main electric panel with new main electric panel including new 125a main breaker. existing meter can to remain in place. this is not a service upgrade just a panel upgrade. existing service to remain at 125a. overhead service. includes installation of exterior nema 14-50 outlet to supply power to a plug-in ev charger. installation done according to austin energys plugin rebate guidelines. **includes addition of 20a circuit to power cowboy pool heat pump. conduit/wire to run from bottom of panel along foundation to back of home and then underground through an approximately 30 trench
Temporary disconnect required. replace existing main electric panel with new main electric panel including new 125a main breaker. existing meter can to remain in place. this is not a service upgrade just a panel upgrade. existing service to remain at 125a. overhead service. includes installation of exterior nema 14-50 outlet to supply power to a plug-in ev charger. installation done according to austin energys plugin rebate guidelines. **includes addition of 20a circuit to power cowboy pool heat pump. conduit/wire to run from bottom of panel along foundation to back of home and then underground through an approximately 30 trench
City of Austin permitElectrical PermitActive- Record
- 2026-124056 EP
- Owner
- Pro
- Contractor
- Pro
- Contact
- Pro
Sources: City of Austin
Questions about 2905 E 14th St
What is being built at 2905 E 14th St?
An active electrical permit covers a replacement main panel, an exterior outlet for a plug-in EV charger, and a circuit for a Cowboy Pool heat pump. The permit was filed September 24, 2026.
Is a new pool being built at 2905 E 14th St?
The permit describes a 20-amp circuit to power a Cowboy Pool heat pump. It does not describe construction of a pool.
Is an EV charger being installed at 2905 E 14th St?
The permit includes an exterior NEMA 14-50 outlet to supply power to a plug-in EV charger. It does not specify installation of the charger itself.
Is the electrical service being upgraded at 2905 E 14th St?
No. Permit 2026-124056 EP says the existing 125-amp service will remain and describes the work as a panel upgrade, not a service upgrade.
When was the electrical permit filed for 2905 E 14th St?
The City of Austin permit was filed September 24, 2026. It is listed as active.
Also being built nearby
All of 78702- 2907 E 14th StOct 18, 2026Upgrade existing electric service to 200a. includes new 200a meter can and new 200a main distribution panel. overhead service. occupied residence · 10 m away
- 2900 E 14th StNov 7, 2024Install new 50 amp stove power80 amp outdoor panel with a 30 amp rv connection · 49 m away
- 1316-1/2 Alexander AveJan 21, 2022Upper boggy creek trail phase 1 · 53 m away
- 2906 E 13th StJan 30, 2024Install evse at garage · 78 m away
- 2908 E 13th StAug 19, 202510 tunnel below the foundation to repair break on kitchen drain line. 1 access hole - left · 80 m away
- 2900 E 13th StJun 4, 2026Replacement of complete existing central heat and air system with or without duct work · 82 m away
- 2918 E 14th StApr 5, 2024Replacement of complete existing central heat and air system with or without duct work · 92 m away
- 2912 E 13th StJul 31, 2024Irrigation · 93 m away
- 2921 E 14th StNov 9, 2026Replacement of complete existing central heat and air system with or without duct work 1 system: 3 ton 14 seer2 single stage condenser evaporator coil and gas furnace · 95 m away
- 2914 E 13th StJan 2, 2024Construct new driveway approach of 16 ft. no sidewalk inspection per plan review. *rs · 99 m away
- 1404 Clifford AveMay 24, 2024Replacement of complete existing central heat and air system with or without duct work · 117 m away
- 2920 E 13th StJul 29, 2024Replacement of mini-split system · 123 m away
More pools in 78702.