604 E 49th St
Austin, TX 78751
Electrical circuits added at 604 E 49th St
An electrical permit covers new bathroom and living room circuits at the residence at 604 E 49th St. The City of Austin issued the permit on September 3, 2026; the work includes bathroom receptacles and a new living room receptacle circuit.
Summarized from City of Austin records · updated Sep 3, 2026
- Projects
- 1
- 1 filings
- Latest filing
- Sep 3, 2026
- since Sep 3, 2026
- Largest scope
- —
- Listed value
- —
Permit & project history
1 projectThis permit will cover: bathroom circuits living room receptacles bathroom circuits recently purchased older residence; existing bathroom has no receptacle outlets. bathroom walls have original tile the homeowner wants to preserve. receptacles will be surface mounted inside the cabinets flanking the sink to avoid cutting into the tile meeting the 3 ft basin-proximity requirement. adds 2 new 20a 120v gfci breaker-protected circuits for bathroom receptacles run through a 1 emt raceway from the exterior main panel to an accessible attic j-box allowing easier future circuit additions. this raceway also carries the living room circuit below. installation: install 1 raceway from panel to a centrally located 8x8x6 j-box in accessible attic space. from there pipe to a 4-square j-box above the bathroom then into the upper cabinets on either side of the sink. install surface-mount quad receptacles with industrial covers inside the cabinets. living room receptacles adds a 20a 120v afci-protected circuit for in-wall receptacles in the living room located behind a future bookshelf. shares the 1 emt raceway from panel to the 8x8x6 j-box branching separately from that point. installation: from the 8x8x6 j-box pipe to a new 4-square box above the bookshelf location then down to the receptacle locations. wire size: all three circuits supplied with #10 thwn-2 sized for high attic temperatures and conductor-count adjustments. all raceways installed per code; terminations torqued per manufacturer specifications
This permit will cover: bathroom circuits living room receptacles bathroom circuits recently purchased older residence; existing bathroom has no receptacle outlets. bathroom walls have original tile the homeowner wants to preserve. receptacles will be surface mounted inside the cabinets flanking the sink to avoid cutting into the tile meeting the 3 ft basin-proximity requirement. adds 2 new 20a 120v gfci breaker-protected circuits for bathroom receptacles run through a 1 emt raceway from the exterior main panel to an accessible attic j-box allowing easier future circuit additions. this raceway also carries the living room circuit below. installation: install 1 raceway from panel to a centrally located 8x8x6 j-box in accessible attic space. from there pipe to a 4-square j-box above the bathroom then into the upper cabinets on either side of the sink. install surface-mount quad receptacles with industrial covers inside the cabinets. living room receptacles adds a 20a 120v afci-protected circuit for in-wall receptacles in the living room located behind a future bookshelf. shares the 1 emt raceway from panel to the 8x8x6 j-box branching separately from that point. installation: from the 8x8x6 j-box pipe to a new 4-square box above the bookshelf location then down to the receptacle locations. wire size: all three circuits supplied with #10 thwn-2 sized for high attic temperatures and conductor-count adjustments. all raceways installed per code; terminations torqued per manufacturer specifications
City of Austin permitElectrical PermitActive- Record
- 2026-114192 EP
- Owner
- Pro
- Contractor
- Pro
- Contact
- Pro
Sources: City of Austin
Questions about 604 E 49th St
What is being built at 604 E 49th St in Austin?
A City of Austin electrical permit covers new bathroom and living room circuits at the residence. It does not describe a new building.
What work is planned at 604 E 49th St?
The permit covers two new circuits for bathroom receptacles and one new circuit for living room receptacles. The bathroom outlets are planned inside cabinets flanking the sink.
When was the electrical permit filed for 604 E 49th St?
The permit was filed on September 3, 2026. Its number is 2026-114192 EP.
Is a new home being built at 604 E 49th St?
The permit describes electrical work at an existing residence, not new home construction.
What does permit 2026-114192 EP cover?
The City of Austin permit covers bathroom receptacle circuits and a living room receptacle circuit at 604 E 49th St. It was filed on September 3, 2026.
Also being built nearby
All of 78751- 606 E 49th StAug 20, 2026Replacement of complete existing central heat and air system with or without duct work mcarton · 19 m away
- 600 E 49th StNov 3, 2026Interior remodel - convert to upstairs/downstairs duplex by closing off a single cased opening and remodeling upstairs bar area. no increase in bedrooms bathrooms or square footage · 30 m away
- 608 E 49th StDec 30, 2025Replacement of complete existing central heat and air system with or without duct work · 31 m away
- 603 E 49th StJul 7, 2026Temporary power panel ref: 2025 091605 bp · 54 m away
- 607 E 49th StAug 21, 2025Replacement of complete existing central heat and air system with or without duct work main house on the right not the duplex on the left · 63 m away
- 612 E 49th StAug 1, 2024Replacement of complete existing central heat and air system with or without duct work · 79 m away
- 613 E 50th StFeb 2, 2026New 2 story unit 2 bed 2.5 bath with attached carport and balcony covered front/rear porch · 82 m away
- 508 E 49th StOct 30, 2025Relocate gas meter due to electrical service upgrade gas test needed · 97 m away
- 705 E 50th StMay 1, 2025Construct new driveway approach of 10 ft and with a new walkway connecting from sidewalk to residence of 2.33 ft · 98 m away
- 513 E 49th StMay 22, 2025Replacement of an existing water heater · 101 m away
- 5005 Martin AveAug 19, 2026Replacement of complete existing central heat and air system with or without duct work hvac change out · 113 m away
- 700 E 49th StOct 20, 2026Express: foundation repair · 113 m away