Electrical permit for an IT equipment receptacle

An electrical permit filed December 10, 2025, covers adding a 30-amp, 120-volt twist-lock receptacle for IT equipment in Building 2. The work extends an existing circuit in the building’s electrical room; permit 2025-153397 EP is marked final.

Summarized from City of Austin records · updated Dec 10, 2025

Projects
1
1 filings
Latest filing
Dec 10, 2025
since Dec 10, 2025
Largest scope
—
Listed value
—

Where this project stands

Finaled

Add (1) 30a. 120v twist lock receptacle on an existing dedicated circuit for it rack in electrical room for building 2 *the circuit that we want to extend is existing and is listed in the existing panel directory as it rack. the circuit was routed to a junction box in the existing electrical room and the past contractor never completed the installation of the it receptacle and abandoned the circuit in the junction box within the electrical room of building 2. we need to extend this existing circuit about 15 via 3/4 emt conduit with (3) #10s and install the outlet box with a new 30amp twistlock device in it for connection of it equipment

  1. AppliedDec 2, 2025
  2. IssuedDec 10, 2025
  3. WorkDec '25 – Feb '26
  4. Final inspectionFeb 27, 2026

Passed final inspection Feb 27, 2026.

1 contact on this project · 1 phone number

Permit & project history

1 project
  1. Add (1) 30a. 120v twist lock receptacle on an existing dedicated circuit for it rack in electrical room for building 2 *the circuit that we want to extend is existing and is listed in the existing panel directory as it rack. the circuit was routed to a junction box in the existing electrical room and the past contractor never completed the installation of the it receptacle and abandoned the circuit in the junction box within the electrical room of building 2. we need to extend this existing circuit about 15 via 3/4 emt conduit with (3) #10s and install the outlet box with a new 30amp twistlock device in it for connection of it equipment

    Add (1) 30a. 120v twist lock receptacle on an existing dedicated circuit for it rack in electrical room for building 2 *the circuit that we want to extend is existing and is listed in the existing panel directory as it rack. the circuit was routed to a junction box in the existing electrical room and the past contractor never completed the installation of the it receptacle and abandoned the circuit in the junction box within the electrical room of building 2. we need to extend this existing circuit about 15 via 3/4 emt conduit with (3) #10s and install the outlet box with a new 30amp twistlock device in it for connection of it equipment

    City of Austin permitElectrical PermitFinal
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro

Sources: City of Austin

Questions about 1117 S Congress Ave

What is being built at 1117 S Congress Ave?

A City of Austin electrical permit covers adding a 30-amp, 120-volt twist-lock receptacle for IT equipment in Building 2. It does not describe a new building.

When was the electrical work at 1117 S Congress Ave permitted?

The permit was filed December 10, 2025. Permit number 2025-153397 EP is marked final.

What is permit 2025-153397 EP for?

It covers extending an existing circuit in Building 2’s electrical room and installing a twist-lock receptacle for IT equipment.

Is a new business opening at 1117 S Congress Ave?

The available permit records describe electrical work for IT equipment, not a new business or tenant.

What is happening near the Texas School for the Deaf on South Congress?

At 1117 S Congress Ave, a December 10, 2025, electrical permit covers an IT equipment receptacle in Building 2. The nearby Texas School for the Deaf project at 1102 S Congress Ave is listed separately.

Is construction planned next to Brochu Walker on South Congress?

The record for 1117 S Congress Ave is for electrical work in Building 2, not a broader construction project. Brochu Walker is listed nearby at 1204 S Congress Ave.

Also being built nearby

All of 78704
Email me when a new permit is filed