groundranger
Active · latest filing Oct 2026Commercial

2900 Rio Grande St

Austin, TX 78705

2900 Rio Grande restaurant rebuild after fire damage

City of Austin permits indicate a 5,332-square-foot remodel to rebuild an existing restaurant after fire damage. The building permit was filed March 31, 2025, followed by plumbing, electrical and mechanical permits. A separate 2026 permit covers electrical work for a neon pole sign.

Summarized from City of Austin records · updated Oct 22, 2026

Projects
7
7 filings
Latest filing
Oct 22, 2026
since Mar 31, 2025
Largest scope
—
Listed value
—

Where this project stands

Permit active · work underway

Overview provide dedicated gfci protected branch circuit for business neon pole sign. install wire raceway in hard pipe for entirety of run from exterior panel on salado st. to sign location on rio grande. details install imc on back of lower concrete block wall which runs across restaurants outdoor garden area. transition to schedule 80 pvc for approx 20ft under gravel garden pedestrian entrance and then transition back to imc for remainder of run along block wall terminating at lockable nema 3 non-fused disconnect within sight of sign. sign and pole and equipment will be grounded and bonded per requirements of nec 600.7. all raceways installed per city and nec code requirements; terminations will be torqued per manufacturers specifications

  1. AppliedSep 30, 2026
  2. IssuedOct 22, 2026
  3. WorkOct '26 – May '27
  4. Final inspection
14% through of the permit windowOct 22, 2026 → May 5, 2027

1 contact on this project · 1 phone number

Permit & project history

7 projects
  1. Overview provide dedicated gfci protected branch circuit for business neon pole sign. install wire raceway in hard pipe for entirety of run from exterior panel on salado st. to sign location on rio grande. details install imc on back of lower concrete block wall which runs across restaurants outdoor garden area. transition to schedule 80 pvc for approx 20ft under gravel garden pedestrian entrance and then transition back to imc for remainder of run along block wall terminating at lockable nema 3 non-fused disconnect within sight of sign. sign and pole and equipment will be grounded and bonded per requirements of nec 600.7. all raceways installed per city and nec code requirements; terminations will be torqued per manufacturers specifications

    Overview provide dedicated gfci protected branch circuit for business neon pole sign. install wire raceway in hard pipe for entirety of run from exterior panel on salado st. to sign location on rio grande. details install imc on back of lower concrete block wall which runs across restaurants outdoor garden area. transition to schedule 80 pvc for approx 20ft under gravel garden pedestrian entrance and then transition back to imc for remainder of run along block wall terminating at lockable nema 3 non-fused disconnect within sight of sign. sign and pole and equipment will be grounded and bonded per requirements of nec 600.7. all raceways installed per city and nec code requirements; terminations will be torqued per manufacturers specifications

    City of Austin permitElectrical PermitActive
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  2. Construct new sidewalk of 41 lf *** row usage fee paid for 2 days for the sidewalk repair

    Construct new sidewalk of 41 lf *** row usage fee paid for 2 days for the sidewalk repair

    City of Austin permitDriveway / SidewalksFinal
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  3. Installation of fireline

    Installation of fireline

    City of Austin permitPlumbing PermitFinal
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  4. Eplan: expedited review - [approved] remodel to an existing restaurant to rebuild due to fire damage (5332 sq ft)

    Eplan: expedited review - [approved] remodel to an existing restaurant to rebuild due to fire damage (5332 sq ft)

    City of Austin permitMechanical PermitFinal
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  5. Eplan: expedited review - [approved] remodel to an existing restaurant to rebuild due to fire damage (5332 sq ft)

    Eplan: expedited review - [approved] remodel to an existing restaurant to rebuild due to fire damage (5332 sq ft)

    City of Austin permitElectrical PermitFinal
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  6. Eplan: expedited review - [approved] remodel to an existing restaurant to rebuild due to fire damage (5332 sq ft)

    Eplan: expedited review - [approved] remodel to an existing restaurant to rebuild due to fire damage (5332 sq ft)

    City of Austin permitPlumbing PermitFinal
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  7. Eplan: expedited review - [approved] remodel to an existing restaurant to rebuild due to fire damage (5332 sq ft)

    Eplan: expedited review - [approved] remodel to an existing restaurant to rebuild due to fire damage (5332 sq ft)

    City of Austin permitBuilding PermitFinal
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro

Sources: City of Austin

Questions about 2900 Rio Grande St

What is being built at 2900 Rio Grande St?

City of Austin permits describe a 5,332-square-foot remodel to rebuild an existing restaurant after fire damage. The records do not identify a tenant.

Is a new restaurant opening at 2900 Rio Grande St?

The permits describe work to rebuild an existing restaurant after fire damage, not a new restaurant opening. They do not provide an opening date or identify an operator.

When was the restaurant rebuild at 2900 Rio Grande permitted?

The building permit, 2024-080160 BP, was filed March 31, 2025. Plumbing, electrical and mechanical permits followed from July through November 2025.

What work do the permits cover at 2900 Rio Grande?

The 2025 permits cover a remodel of an existing restaurant to rebuild after fire damage. Other records cover a fireline installation, a sidewalk, and electrical work for a neon pole sign.

What is the latest permit for 2900 Rio Grande St?

The latest listed permit is 2026-129157 EP, filed October 22, 2026. It covers a dedicated electrical circuit and raceway for a business neon pole sign.

How large is the restaurant remodel at 2900 Rio Grande?

The City of Austin permit descriptions identify the remodel as 5,332 square feet.

Also being built nearby

All of 78705

More restaurants in 78705.

Email me when it passes final inspection