2603 Lansbury Dr
Austin, TX 78723
2603 Lansbury Dr: 2 projects on record
City of Austin lists 2 filings across 2 projects at 2603 Lansbury Dr, Austin, TX 78723. The most recent, filed May 29, 2025, covers: “Replacement of complete existing central heat and air system with or without duct work”.
Compiled from City of Austin records · updated May 29, 2025
- Projects
- 2
- 2 filings
- Latest filing
- May 29, 2025
- since May 29, 2025
- Largest scope
- —
- Listed value
- —
Where this project stands
FinaledReplacement of complete existing central heat and air system with or without duct work
- AppliedMay 27, 2025
- IssuedMay 29, 2025
- WorkMay '25 – Jul '25
- Final inspectionJul 15, 2025
Passed final inspection Jul 15, 2025.
1 contact on this project · 1 phone number
Permit & project history
2 projectsReplacement of complete existing central heat and air system with or without duct work
Replacement of complete existing central heat and air system with or without duct work
City of Austin permitMechanical PermitFinal- Record
- 2025-065134 MP
- Owner
- Pro
- Contractor
- Pro
- Contact
- Pro
Replace 55 of sewerline which 10 tunnel is under slab
Replace 55 of sewerline which 10 tunnel is under slab
City of Austin permitPlumbing PermitFinal- Record
- 2023-061874 PP
- Owner
- Pro
- Contractor
- Pro
- Contact
- Pro
Sources: City of Austin
Questions about 2603 Lansbury Dr
What is being built at 2603 Lansbury Dr?
The latest filing (City of Austin permit 2025-065134 MP, May 29, 2025) covers replacement of complete existing central heat and air system with or without duct work.
How many permits and filings does 2603 Lansbury Dr have?
2 filings across 2 projects, from May 29, 2025 to May 29, 2025.
Is there other construction near 2603 Lansbury Dr?
Yes. Nearby filings include 2601 Lansbury Dr (solar system never was modified during the house remodel. feel free to contact the electrical contractor if you have any questions about this project. (737) 333-6073, Mar 24, 2026); 2602 Lansbury Dr (replace existing sewer under home with pvc and reroute kitchen and laundry drain due to bellies and damage cast iron. will dig a tunnel 18 ft under home, Nov 14, 2025); 2604 Lansbury Dr (installation of 7.92kw with pv solar system with battery backup, Nov 6, 2026).
How do I get alerts for new permits at 2603 Lansbury Dr?
Watch this address on groundranger and you'll get an email when a new permit or project filing appears here or nearby.
Also being built nearby
All of 78723- 2601 Lansbury DrMar 24, 2026Solar system never was modified during the house remodel. feel free to contact the electrical contractor if you have any questions about this project. (737) 333-6073 · 24 m away
- 2602 Lansbury DrNov 14, 2025Replace existing sewer under home with pvc and reroute kitchen and laundry drain due to bellies and damage cast iron. will dig a tunnel 18 ft under home · 48 m away
- 2604 Lansbury DrNov 6, 2026Installation of 7.92kw with pv solar system with battery backup · 50 m away
- 2507 Lansbury DrAug 12, 2026Replacement of complete existing central heat and air system with or without duct work change one gas unit like for like with no duct work · 57 m away
- 5710 Exeter DrAug 10, 2026Replacement of complete existing central heat and air system with or without duct work · 62 m away
- 2606 Lansbury DrApr 29, 2026Interior remodel- general demolition [of interior material to be replaced]; minor framing repairs replace drywall finish carpentry paint flooring replacement · 62 m away
- 2504 Roxmoor DrMar 28, 2025Install a water sewer yard line · 72 m away
- 2601 Roxmoor DrAug 27, 2025Emergency replaced damaged riser · 87 m away
- 2610 Lansbury DrJan 17, 2024Expedited review: interior remodel to existing 2-story single family res. addition to include new guest room additional bath relocate master to second floor new stairs to second floor deck expand existing baths and install new hvac. [4bed 3bath] · 98 m away
- 2502 Roxmoor DrMar 17, 2025200a service upgrade (using ute4213bch meter). rebuild & upgrade existing main electrical service on residence. & replace the sub panel and sub panel feeder wire · 103 m away
- 5704 Exeter DrJun 10, 2024Replacement of complete existing central heat and air system with or without duct work · 106 m away
- 5709 Exeter DrMay 26, 2026**kitchen range:** upgrade existing 15a gas range circuit (currently mixed 8/3 and 14/2) to a 40a (120/240v) circuit. replace the existing 14/2 portion of the circuit with new 8/3 nm-b from an attic junction box to the range location. install nema 14-50r receptacle. install a dedicated egc to the attic junction box from a known good 10awg ground in an existing nearby junction box per nec 250.130(c) and table 250.122. - panel: replace existing 15a single-pole breaker with a new 40a double-pole gfci breaker. **kitchen mwbc correction:** correct existing nonconforming modifications to the original 12/3 kitchen mwbc. replace existing undersized 14/2 cable serving the final two receptacles with new 12/3 nm-b cable. replace existing 14/3 splice segment in the homerun with new 12/3 nm-b cable. - panel: install (2) new 20a single-pole afci breakers with an approved handle tie. **relocate 15a branch circuit:** move an existing 14/2 branch circuit (which was previously tapped from the kitchen mwbc splice) to its own new 15a branch circuit utilizing existing spare thhn conductors that run from the service panel to an existing attic junction box. - panel: install a new 15a gfci breaker. **bedrooms & living room:** install a new dedicated 20a branch circuit using existing spare thhn conductors (a completely separate pair from the thhn conductors mentioned above) that run from the service panel to an existing attic junction box. on this new circuit install (2) new convenience receptacles in bedroom 1 (1) new closet light fixture with a wall switch in bedroom 2 and (2) new convenience receptacle in the living room. - panel: install new 20a afci breaker · 112 m away