5711 Sandhurst Cir
Austin, TX 78723
5711 Sandhurst Cir: 1 project on record
City of Austin lists 1 filing across 1 project at 5711 Sandhurst Cir, Austin, TX 78723. The most recent, filed October 9, 2024, covers: “Upgrade of exterior electrical service”.
Compiled from City of Austin records · updated Oct 9, 2024
- Projects
- 1
- 1 filings
- Latest filing
- Oct 9, 2024
- since Oct 9, 2024
- Largest scope
- —
- Listed value
- —
Where this project stands
FinaledUpgrade of exterior electrical service
- AppliedSep 18, 2024
- IssuedOct 9, 2024
- WorkOct '24 – Feb '25
- Final inspectionFeb 28, 2025
Passed final inspection Feb 28, 2025.
1 contact on this project · 1 phone number
Permit & project history
1 projectUpgrade of exterior electrical service
Upgrade of exterior electrical service
City of Austin permitElectrical PermitFinal- Record
- 2024-126656 EP
- Owner
- Pro
- Contractor
- Pro
- Contact
- Pro
Sources: City of Austin
Questions about 5711 Sandhurst Cir
What is being built at 5711 Sandhurst Cir?
The latest filing (City of Austin permit 2024-126656 EP, October 9, 2024) covers upgrade of exterior electrical service.
How many permits and filings does 5711 Sandhurst Cir have?
1 filing across 1 project, from October 9, 2024 to October 9, 2024.
Is there other construction near 5711 Sandhurst Cir?
Yes. Nearby filings include 5704 Sandhurst Cir (express: replace roof replace 3 windows 1 siding door replace 20 ft siding, Aug 24, 2026); 5709 Exeter Dr (**kitchen range:** upgrade existing 15a gas range circuit (currently mixed 8/3 and 14/2) to a 40a (120/240v) circuit. replace the existing 14/2 portion of the circuit with new 8/3 nm-b from an attic junction box to the range location. install nema 14-50r receptacle. install a dedicated egc to the attic junction box from a known good 10awg ground in an existing nearby junction box per nec 250.130(c) and table 250.122. - panel: replace existing 15a single-pole breaker with a new 40a double-pole gfci breaker. **kitchen mwbc correction:** correct existing nonconforming modifications to the original 12/3 kitchen mwbc. replace existing undersized 14/2 cable serving the final two receptacles with new 12/3 nm-b cable. replace existing 14/3 splice segment in the homerun with new 12/3 nm-b cable. - panel: install (2) new 20a single-pole afci breakers with an approved handle tie. **relocate 15a branch circuit:** move an existing 14/2 branch circuit (which was previously tapped from the kitchen mwbc splice) to its own new 15a branch circuit utilizing existing spare thhn conductors that run from the service panel to an existing attic junction box. - panel: install a new 15a gfci breaker. **bedrooms & living room:** install a new dedicated 20a branch circuit using existing spare thhn conductors (a completely separate pair from the thhn conductors mentioned above) that run from the service panel to an existing attic junction box. on this new circuit install (2) new convenience receptacles in bedroom 1 (1) new closet light fixture with a wall switch in bedroom 2 and (2) new convenience receptacle in the living room. - panel: install new 20a afci breaker, May 26, 2026); 2610 Lansbury Dr (expedited review: interior remodel to existing 2-story single family res. addition to include new guest room additional bath relocate master to second floor new stairs to second floor deck expand existing baths and install new hvac. [4bed 3bath], Jan 17, 2024).
How do I get alerts for new permits at 5711 Sandhurst Cir?
Watch this address on groundranger and you'll get an email when a new permit or project filing appears here or nearby.
Also being built nearby
All of 78723- 5704 Sandhurst CirAug 24, 2026Express: replace roof replace 3 windows 1 siding door replace 20 ft siding · 91 m away
- 5709 Exeter DrMay 26, 2026**kitchen range:** upgrade existing 15a gas range circuit (currently mixed 8/3 and 14/2) to a 40a (120/240v) circuit. replace the existing 14/2 portion of the circuit with new 8/3 nm-b from an attic junction box to the range location. install nema 14-50r receptacle. install a dedicated egc to the attic junction box from a known good 10awg ground in an existing nearby junction box per nec 250.130(c) and table 250.122. - panel: replace existing 15a single-pole breaker with a new 40a double-pole gfci breaker. **kitchen mwbc correction:** correct existing nonconforming modifications to the original 12/3 kitchen mwbc. replace existing undersized 14/2 cable serving the final two receptacles with new 12/3 nm-b cable. replace existing 14/3 splice segment in the homerun with new 12/3 nm-b cable. - panel: install (2) new 20a single-pole afci breakers with an approved handle tie. **relocate 15a branch circuit:** move an existing 14/2 branch circuit (which was previously tapped from the kitchen mwbc splice) to its own new 15a branch circuit utilizing existing spare thhn conductors that run from the service panel to an existing attic junction box. - panel: install a new 15a gfci breaker. **bedrooms & living room:** install a new dedicated 20a branch circuit using existing spare thhn conductors (a completely separate pair from the thhn conductors mentioned above) that run from the service panel to an existing attic junction box. on this new circuit install (2) new convenience receptacles in bedroom 1 (1) new closet light fixture with a wall switch in bedroom 2 and (2) new convenience receptacle in the living room. - panel: install new 20a afci breaker · 98 m away
- 2610 Lansbury DrJan 17, 2024Expedited review: interior remodel to existing 2-story single family res. addition to include new guest room additional bath relocate master to second floor new stairs to second floor deck expand existing baths and install new hvac. [4bed 3bath] · 119 m away
- 5700 Sandhurst CirJun 10, 2024Pulled gas meter find and repair leaks and replace gas valves to code · 126 m away
- 5900 Manor RdJun 2, 2025Create a tunnel to repair piping system under building the has back fall. access pipes under building and repair with proper pitch · 137 m away
- 5709 Manor RdApr 4, 2024Replace indoor federal 125 amp panel with 125 amp ge panel · 140 m away
- 5710 Exeter DrAug 10, 2026Replacement of complete existing central heat and air system with or without duct work · 143 m away
- 5908 Manor RdAug 28, 2024Replace existing pole light fixtures one for one with full cutoff led fixtures utilizing existing circuitry and controls · 144 m away
- 5703 Manor RdAug 9, 2026Change of use from sfr to office - no remodel work · 146 m away
- 5701 Exeter DrSep 22, 2025Express: 4700 sq ft decking removal and replacement · 149 m away
- 5704 Exeter DrJun 10, 2024Replacement of complete existing central heat and air system with or without duct work · 158 m away
- 5802 Sweeney CirSep 23, 2010Pecan springs common phase one · 160 m away