groundranger
Recent · latest filing Jan 2026Residential

5900 Carry Back Ln

Austin, TX 78746

Permits cover a 26-kW whole-home generator installation

Austin permits filed Jan. 7 and 9, 2026, indicate work to install a 26-kW whole-home generator at 5900 Carry Back Ln. The permits cover a gas line to the generator and electrical work, including a 200-amp automatic transfer switch, additional grounding and Type 2 surge protection.

Summarized from City of Austin records · updated Jan 9, 2026

Projects
2
2 filings
Latest filing
Jan 9, 2026
since Jan 7, 2026
Largest scope
—
Listed value
—

Where this project stands

Finaled

Installation of a 200a automatic transfer switch 26kw whole home generator additional grounding and type 2 surge protection

  1. AppliedJan 8, 2026
  2. IssuedJan 9, 2026
  3. WorkJan '26 – Feb '26
  4. Final inspectionFeb 11, 2026

Passed final inspection Feb 11, 2026.

1 contact on this project · 1 phone number

Permit & project history

2 projects
  1. Installation of a 200a automatic transfer switch 26kw whole home generator additional grounding and type 2 surge protection

    Installation of a 200a automatic transfer switch 26kw whole home generator additional grounding and type 2 surge protection

    City of Austin permitElectrical PermitFinal
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  2. Run 1.25 - 21 black iron mounted 10 poly trenched to generator

    Run 1.25 - 21 black iron mounted 10 poly trenched to generator

    City of Austin permitPlumbing PermitFinal
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro

Sources: City of Austin

Questions about 5900 Carry Back Ln

What is being installed at 5900 Carry Back Ln?

Austin permits indicate installation of a 26-kW whole-home generator, with related gas line and electrical work.

How large is the generator planned for 5900 Carry Back Ln?

The electrical permit describes a 26-kW whole-home generator.

What electrical work is permitted at 5900 Carry Back Ln?

Permit 2026-002582 EP, filed Jan. 9, 2026, covers a 200-amp automatic transfer switch, additional grounding and Type 2 surge protection for the generator.

Is a gas line being installed for the generator at 5900 Carry Back Ln?

A plumbing permit filed Jan. 7, 2026, describes running a line to the generator.

When were the generator permits filed for 5900 Carry Back Ln?

The plumbing permit, 2026-001307 PP, was filed Jan. 7, 2026, and the electrical permit, 2026-002582 EP, was filed Jan. 9, 2026. Both records show final status.

Also being built nearby

All of 78746
Email me when a new permit is filed