2701 Steck Ave
Austin, TX 78757
2701 Steck Ave: 1 project on record
City of Austin lists 1 filing across 1 project at 2701 Steck Ave, Austin, TX 78757. The most recent, filed August 11, 2025, covers: “A whole house sewer re-pipe. tunnel and yard line”.
Compiled from City of Austin records · updated Aug 11, 2025
- Projects
- 1
- 1 filings
- Latest filing
- Aug 11, 2025
- since Aug 11, 2025
- Largest scope
- —
- Listed value
- —
Where this project stands
FinaledA whole house sewer re-pipe. tunnel and yard line
- AppliedAug 10, 2025
- IssuedAug 11, 2025
- WorkAug '25 – Sep '25
- Final inspectionSep 3, 2025
Passed final inspection Sep 3, 2025.
1 contact on this project · 1 phone number
Permit & project history
1 projectA whole house sewer re-pipe. tunnel and yard line
A whole house sewer re-pipe. tunnel and yard line
City of Austin permitPlumbing PermitFinal- Record
- 2025-100988 PP
- Owner
- Pro
- Contractor
- Pro
- Contact
- Pro
Sources: City of Austin
Questions about 2701 Steck Ave
What is being built at 2701 Steck Ave?
The latest filing (City of Austin permit 2025-100988 PP, August 11, 2025) covers a whole house sewer re-pipe. tunnel and yard line.
How many permits and filings does 2701 Steck Ave have?
1 filing across 1 project, from August 11, 2025 to August 11, 2025.
Is there other construction near 2701 Steck Ave?
Yes. Nearby filings include 2604 Clarkdale Ln (this is separate work from the plumbing permit 2026-099373 pp that we are not associated with. this is warranty work from work we did in the past. there is an open ditch that we need to backfill asap. mary upon arrival met with the excavation crew at 2604 clarkdale ln. austin tx 78757 to perform additional camera diagnostics and establish the excavation location. camera inspections were performed through the kitchen sink vent as well as the laundry vent and laundry drain line. pvc drainage piping was observed throughout the accessible portions of the system with the exception of the kitchen drain line. while inspecting the kitchen drain the camera was advanced to approximately one foot below slab level where a significant separation break or obstruction was encountered. the camera could not be advanced beyond this location preventing further visual confirmation of the downstream piping. based on the camera location and site conditions we determined that accessing the affected area from the front of the home is the most practical approach. this requires approximately one additional foot of excavation compared with accessing the piping through the rear patio. rear access would require disturbing the concrete surrounding the pool area which would be significantly more difficult to restore and match properly. pvc piping was observed penetrating the slab and appears to continue into or through a structural beam beneath the foundation. the suspected failure is located in this general area. the excavation crew will proceed with carefully excavating and gaining access to the affected piping over approximately the next two days. once the piping is fully exposed we will evaluate the exact condition and configuration of the drainage system confirm the cause and extent of the failure and develop the appropriate repair plan based on the conditions found. with the excavation completed and the damaged piping identified, Nov 6, 2026); 8200 Valleydale Cv (replacement of complete existing central heat and air system with or without duct work, Dec 11, 2025); 2600 Clarkdale Ln (new pool, Nov 18, 2026).
How do I get alerts for new permits at 2701 Steck Ave?
Watch this address on groundranger and you'll get an email when a new permit or project filing appears here or nearby.
Also being built nearby
All of 78757- 2604 Clarkdale LnNov 6, 2026This is separate work from the plumbing permit 2026-099373 pp that we are not associated with. this is warranty work from work we did in the past. there is an open ditch that we need to backfill asap. mary upon arrival met with the excavation crew at 2604 clarkdale ln. austin tx 78757 to perform additional camera diagnostics and establish the excavation location. camera inspections were performed through the kitchen sink vent as well as the laundry vent and laundry drain line. pvc drainage piping was observed throughout the accessible portions of the system with the exception of the kitchen drain line. while inspecting the kitchen drain the camera was advanced to approximately one foot below slab level where a significant separation break or obstruction was encountered. the camera could not be advanced beyond this location preventing further visual confirmation of the downstream piping. based on the camera location and site conditions we determined that accessing the affected area from the front of the home is the most practical approach. this requires approximately one additional foot of excavation compared with accessing the piping through the rear patio. rear access would require disturbing the concrete surrounding the pool area which would be significantly more difficult to restore and match properly. pvc piping was observed penetrating the slab and appears to continue into or through a structural beam beneath the foundation. the suspected failure is located in this general area. the excavation crew will proceed with carefully excavating and gaining access to the affected piping over approximately the next two days. once the piping is fully exposed we will evaluate the exact condition and configuration of the drainage system confirm the cause and extent of the failure and develop the appropriate repair plan based on the conditions found. with the excavation completed and the damaged piping identified · 46 m away
- 8200 Valleydale CvDec 11, 2025Replacement of complete existing central heat and air system with or without duct work · 63 m away
- 2600 Clarkdale LnNov 18, 2026New pool · 84 m away
- 8113 Parkdale DrApr 2, 2025Express: replace 8 windows like for like · 115 m away
- 8115 Parkdale DrAug 18, 2026Replacement of complete existing central heat and air system with or without duct work · 116 m away
- 8104 Parkdale DrApr 8, 2026Lyon - 39-53920 - install new 5.76kw rooftop solar system to existing residential only using backfed breaker · 118 m away
- 8205 Stillwood LnNov 10, 2025Replacement of an existing water heater · 119 m away
- 8109 Parkdale DrMar 8, 2024Express replace siding · 123 m away
- 8114 Stillwood LnMay 13, 2025Replace sewer line from backyard to the city tap. approximately 70 · 123 m away
- 8102 Logwood DrJul 17, 2026Replacement of complete existing central heat and air system with or without duct work · 128 m away
- 8204 Parkdale CvSep 3, 2024Replacement of complete existing central heat and air system with or without duct work · 129 m away
- 8107 Parkdale DrMar 31, 2025Provide electrical wiring for a 200 sq ft free-standing shed · 128 m away