12402 Blue Water Cir
Austin, TX 78758
Austin permits cover home repairs and electrical upgrade
City of Austin permits show foundation and plumbing repairs at the home, followed by an electrical service upgrade. The records were filed between September 5, 2025, and February 27, 2026; all three permits are marked final.
Summarized from City of Austin records · updated Feb 27, 2026
- Projects
- 3
- 3 filings
- Latest filing
- Feb 27, 2026
- since Sep 5, 2025
- Largest scope
- —
- Listed value
- —
Where this project stands
FinaledUpgrade electrical service to 200 amp add ground rod whole home surge protection change meter base change main panel
- AppliedFeb 26, 2026
- IssuedFeb 27, 2026
- WorkFeb '26 – May '26
- Final inspectionMay 8, 2026
Passed final inspection May 8, 2026.
1 contact on this project · 1 phone number
Permit & project history
3 projectsUpgrade electrical service to 200 amp add ground rod whole home surge protection change meter base change main panel
Upgrade electrical service to 200 amp add ground rod whole home surge protection change meter base change main panel
City of Austin permitElectrical PermitFinal- Record
- 2026-023623 EP
- Owner
- Pro
- Contractor
- Pro
- Contact
- Pro
Tunnel spot repair entry hole(s) at the back of the house where the sewer line exits and another entry hole at right side of the home outside of the bathroom. then tunnel underneath the foundation of the house approximately 7 feet under the guest bathroom and approximately 10 feet under the master bathroom to access and expose the drains under the bathrooms. defective drains will be removed from the plumbing system and debris will be hauled away. - drains will then be replaced with new dwv schedule 40 pvc pipe and fittings in accordance with plumbing code trench approximately 15 in the yard to connect the guest bathroom drain to the main sewer line in the yard. reroute the washing machine drain out through the exterior wall and trench approximately 60 around the back of the house and connect the washing machine and kitchen sink drains to the main drain outside of the master bathroom
Tunnel spot repair entry hole(s) at the back of the house where the sewer line exits and another entry hole at right side of the home outside of the bathroom. then tunnel underneath the foundation of the house approximately 7 feet under the guest bathroom and approximately 10 feet under the master bathroom to access and expose the drains under the bathrooms. defective drains will be removed from the plumbing system and debris will be hauled away. - drains will then be replaced with new dwv schedule 40 pvc pipe and fittings in accordance with plumbing code trench approximately 15 in the yard to connect the guest bathroom drain to the main sewer line in the yard. reroute the washing machine drain out through the exterior wall and trench approximately 60 around the back of the house and connect the washing machine and kitchen sink drains to the main drain outside of the master bathroom
City of Austin permitPlumbing PermitFinal- Record
- 2025-122650 PP
- Owner
- Pro
- Contractor
- Pro
- Contact
- Pro
Express - existing foundation repair as per scope of work attached
Express - existing foundation repair as per scope of work attached
City of Austin permitBuilding PermitFinal- Record
- 2025-112893 BP
- Owner
- Pro
- Contractor
- Pro
- Contact
- Pro
Sources: City of Austin
Questions about 12402 Blue Water Cir
What is being built at 12402 Blue Water Cir?
The permits describe repairs and upgrades to an existing home, not new construction. Work includes foundation repair, drain replacement and an electrical service upgrade.
Is a restaurant opening at 12402 Blue Water Cir?
The available City of Austin permit descriptions do not document a restaurant opening. They describe residential foundation, plumbing and electrical work.
What plumbing work was permitted at 12402 Blue Water Cir?
Permit 2025-122650 PP, filed September 30, 2025, describes replacing defective drains and rerouting connections for the washing machine and kitchen sink.
Was the foundation repaired at 12402 Blue Water Cir?
Yes. Building permit 2025-112893 BP, filed September 5, 2025, covers repairs to the existing foundation.
What electrical work was permitted at 12402 Blue Water Cir?
Electrical permit 2026-023623 EP, filed February 27, 2026, covers an upgrade to 200-amp service, a new meter base and main panel, grounding, and whole-home surge protection.
Are the permits for 12402 Blue Water Cir final?
All three City of Austin permits in the records are marked final.
Also being built nearby
All of 78758- 12404 Blue Water CirAug 20, 2025Amnesty co for single-family residence circa 1969 · 33 m away
- 12401 Blue Water CirMar 17, 2025Bagwell - disconnect/reconnect power to tie in pv component and upgrading msp to 125 amps. 125 main breaker. upgrading revenue meter to 200 amps · 60 m away
- 12406 Blue Water CirAug 19, 2025Amnesty co · 62 m away
- 12407 Blue Water CirJun 2, 2026200amp main panel replacement. meter base also grounding system and surge protection addition of afci and gfci electrical provider: austin energy · 71 m away
- 12306 Rolling Hill DrJan 19, 2024Water heater repair/code upgrades. cut out old section of 1/2â� copper and 2â� pvc. reran copper and pvc to line up with new washer box. removed existing homeowner shut off installed new meter nipple and prv · 78 m away
- 12304 Rolling Hill DrNov 6, 2025Repaired a gas leak. its ready for inspection to get the gas turned back on · 94 m away
- 12315 Knoll Ridge DrOct 21, 2025Replacement of an existing water heater replace existing water heater · 110 m away
- 12309 Rolling Hill DrOct 24, 2025Kitchen remodel (includes upgrading the electrical service and adding an ev charger) · 111 m away
- 12327 Blue Water DrJan 21, 2026Replace 15 feet of gas pipe that was rusted and leaking · 125 m away
- 1402 Cardinal Hill DrJul 3, 2024Interior remodel · 125 m away
- 12405 Knoll Ridge DrJun 8, 2026200 amp service upgrade · 136 m away
- 1404 Cardinal Hill DrJun 16, 2026Express: foundation repair - installing 11 ext pilings · 143 m away
More restaurants in 78758.