5215 W Lovers Ln
Dallas, TX 75209
Medical aesthetics clinic planned at 5215 W Lovers Ln
Permits indicate a 1,988-square-foot medical aesthetics clinic is being built out inside the existing retail building at 5215 W Lovers Ln. Plumbing, mechanical and electrical permits were filed June 23, 2026, followed by an interior alteration permit on August 6, 2026.
Summarized from City of Dallas records · updated Aug 6, 2026
- Projects
- 4
- 4 filings
- Latest filing
- Aug 6, 2026
- since Jun 23, 2026
- Largest scope
- —
- Listed value
- —
Permit & project history
4 projectsInterior tenant improvement of a 1,988 sq ft medical aesthetics clinic within an existing single-story retail building. construction type iib, group b occupancy.demolish all existing interior partitions, doors, frames, hardware, and finishes not shown to remain. remove existing ceiling grid and prepare subfloor for new finishes.construct new non-bearing interior metal stud partitions with gypsum board, including acoustically insulated partitions with continuous acoustic sealant and slip-type head joints. new rooms include a flex consult room, consult room, laser room, reception, check-in/check-out, storage, and closet. install new doors, frames, and hardware including passage, lockset, privacy with sound seals, and panic hardware as scheduled.new suspended acoustical tile ceiling grid throughout with gypsum board ceilings at select areas. install shadow reveal transition molding at ceiling type changes.exterior alterations include demolition of existing metal roof fascia and installation of new aluminum and glass storefront system with metal stud framing, batt insulation, fluid-applied air barrier, and metal flashing.new finishes throughout including wood flooring, resilient base, solid surface countertops, paint, and tile
Interior tenant improvement of a 1,988 sq ft medical aesthetics clinic within an existing single-story retail building. construction type iib, group b occupancy.demolish all existing interior partitions, doors, frames, hardware, and finishes not shown to remain. remove existing ceiling grid and prepare subfloor for new finishes.construct new non-bearing interior metal stud partitions with gypsum board, including acoustically insulated partitions with continuous acoustic sealant and slip-type head joints. new rooms include a flex consult room, consult room, laser room, reception, check-in/check-out, storage, and closet. install new doors, frames, and hardware including passage, lockset, privacy with sound seals, and panic hardware as scheduled.new suspended acoustical tile ceiling grid throughout with gypsum board ceilings at select areas. install shadow reveal transition molding at ceiling type changes.exterior alterations include demolition of existing metal roof fascia and installation of new aluminum and glass storefront system with metal stud framing, batt insulation, fluid-applied air barrier, and metal flashing.new finishes throughout including wood flooring, resilient base, solid surface countertops, paint, and tile
City of Dallas permitCommercial Alteration Addition PermitInterior commercial tenant improvement for medical aesthetics clinic. work includes demolition of all existing plumbing piping, fixtures, and equipment serving the whitebox space. cap domestic cold and hot water piping at ceiling mains, cap vent piping at mains, and cut and cap sanitary below floor. patch all unused wall and floor openings.new work includes installation of three sinks (sk-1 locations), one mop sink/floor drain area, and coffee maker connection with watts sd-2 backflow preventer. connect new ¾" hot water to existing hot water loop and connect ¾" hwr to existing water heater. provide new domestic hot water recirculation pump (cp-1). all waste piping to be underfloor unless noted. all piping to be lead-free per the reduction of lead in drinking water act. update existing fire sprinkler system to maintain fully functioning light hazard suppression system coordinated with new ceiling layout
Interior commercial tenant improvement for medical aesthetics clinic. work includes demolition of all existing plumbing piping, fixtures, and equipment serving the whitebox space. cap domestic cold and hot water piping at ceiling mains, cap vent piping at mains, and cut and cap sanitary below floor. patch all unused wall and floor openings.new work includes installation of three sinks (sk-1 locations), one mop sink/floor drain area, and coffee maker connection with watts sd-2 backflow preventer. connect new ¾" hot water to existing hot water loop and connect ¾" hwr to existing water heater. provide new domestic hot water recirculation pump (cp-1). all waste piping to be underfloor unless noted. all piping to be lead-free per the reduction of lead in drinking water act. update existing fire sprinkler system to maintain fully functioning light hazard suppression system coordinated with new ceiling layout
City of Dallas permitCommercial Plumbing PermitWork includes demolition and replacement of existing hvac ductwork, diffusers, and devices not shown to remain.new supply and return ductwork distribution throughout all new and renovated spaces including flex consult room, consult room, laser room, reception, check-in/check-out, storage, and closet. install new slot supply and return diffusers with balancing dampers at all branch take-offs. balance rtu to specified values with outside air balanced to 230 cfm.alternate price includes replacement of existing rooftop unit with new 4-ton unit (208/3ph) with gas heat. contractor to assess condition of existing rtu and notify engineer of any deficiencies. all roof penetrations to be flashed and sealed per manufacturer recommendations
Work includes demolition and replacement of existing hvac ductwork, diffusers, and devices not shown to remain.new supply and return ductwork distribution throughout all new and renovated spaces including flex consult room, consult room, laser room, reception, check-in/check-out, storage, and closet. install new slot supply and return diffusers with balancing dampers at all branch take-offs. balance rtu to specified values with outside air balanced to 230 cfm.alternate price includes replacement of existing rooftop unit with new 4-ton unit (208/3ph) with gas heat. contractor to assess condition of existing rtu and notify engineer of any deficiencies. all roof penetrations to be flashed and sealed per manufacturer recommendations
City of Dallas permitCommercial Mechanical PermitInterior commercial tenant improvement for medical aesthetics clinic. work includes utilizing existing electrical panels with available circuits and spare breakers to serve new layout. relocate existing panel "a" as shown. re-feed existing service disconnects from new meter coordinating with local utility provider.install new 20-amp receptacles throughout renovated rooms including new consult rooms, laser room, reception, and check-in/check-out areas. provide gfci protection at all wet locations and within 29" of hvac equipment per. provide isolated ground receptacles where indicated.install occupancy/vacancy sensors and dimming controls throughout all spaces per 2021 section c405.11. provide battery backup emergency lighting and exit signs wired ahead of switching. install plug load controls per requirements. provide conduit and circuit for new signage. all work to comply with and
Interior commercial tenant improvement for medical aesthetics clinic. work includes utilizing existing electrical panels with available circuits and spare breakers to serve new layout. relocate existing panel "a" as shown. re-feed existing service disconnects from new meter coordinating with local utility provider.install new 20-amp receptacles throughout renovated rooms including new consult rooms, laser room, reception, and check-in/check-out areas. provide gfci protection at all wet locations and within 29" of hvac equipment per. provide isolated ground receptacles where indicated.install occupancy/vacancy sensors and dimming controls throughout all spaces per 2021 section c405.11. provide battery backup emergency lighting and exit signs wired ahead of switching. install plug load controls per requirements. provide conduit and circuit for new signage. all work to comply with and
City of Dallas permitCommercial Electrical Permit
Sources: City of Dallas
Questions about 5215 W Lovers Ln
What is being built at 5215 W Lovers Ln?
Permits describe an interior build-out for a 1,988-square-foot medical aesthetics clinic in an existing single-story retail building. The plans include consultation rooms, a laser room, reception and storage.
When were permits filed for the clinic at 5215 W Lovers Ln?
Plumbing, mechanical and electrical permits were filed June 23, 2026. The interior alteration permit, COM-ALT-ADD-26-001498, was filed August 6, 2026.
How large is the medical aesthetics clinic at 5215 W Lovers Ln?
The City of Dallas alteration permit describes a 1,988-square-foot clinic within the existing retail building.
What rooms are planned for the clinic at 5215 W Lovers Ln?
The permit lists a flex consultation room, a consultation room, a laser room, reception, check-in and check-out areas, storage and a closet.
Does the project at 5215 W Lovers Ln include exterior work?
Yes. The August 6, 2026 alteration permit includes removing the existing metal roof fascia and installing a new aluminum and glass storefront system.
Is the existing rooftop HVAC unit being replaced at 5215 W Lovers Ln?
The mechanical permit describes new ductwork and diffusers. An alternate includes replacing the existing rooftop unit with a new 4-ton unit; the permit does not establish that the alternate will be carried out.
Also being built nearby
All of 75209- 5210 W Lovers LnNov 3, 2026Gas test request · 20 m away
- 5217 W Lovers LnDec 8, 2025Commercial gas test · 32 m away
- 5213 W. Lovers Lane · Prescott Interests Lovers-Inwood LLCFeb 13, 2025Highland park aesthetics — renovation/alteration — 1,068 sq/ft office med spa interior finish-out within an existing one story retail building · 32 m away
- 5213 W Lovers LnAug 31, 2026Electrical remodel · 32 m away
- 5220 W Lovers LnSep 9, 2026Replace damaged wet or deteriorated insulation, install one layer of 0.5" eps coverboard insulations mechanically. install white 60 mil tpo and flashing · 60 m away
- 5201 W Lovers LnSep 15, 2026This location it’s currently vacant electrical new installation 200a disconnect,200a meter,45kva transformer,200a 480/277v breaker panel,120/208v breaker panel · 63 m away
- 5219 W Lovers LnJan 7, 2021Gas test · 64 m away
- 5202 W Lovers LnNov 3, 2026Gas test request · 65 m away
- 5200 W Lovers LnNov 2, 2026Gas test request · 65 m away
- 5007 W Lovers LnJun 30, 2025- install 1 layer of 1.0” iso mechanically attached over existing roofing system. primary slope is inherent in the existing roof deck.- install mechanically attached 60 mil tpo per manufacturer’s guidelines.- install tpo flashing for walls and curbs per manufacturer’s guidelines.- install new shop fabricated 24 ga metal coping in standard kynar colors.- install new 1 shop fabricated four 24 ga metal scuppers.- clean, remove and dispose of all debris incidental to our work.- 20-year manufacturer’s warranty · 77 m away
- 7979 Inwood Road · Prescott Interests Lovers/Inwood LLCAug 20, 2025L & i — renovation/alteration — interior finish out · 101 m away
- 7979 Inwood RdMay 26, 2026Electrical remodel, install new light fixtures and receptacles · 101 m away
More demolitions in 75209, warehouses & industrial in 75209, medical facilities in 75209.