groundranger
Active · latest filing Oct 2026Residential

4415 W Lawther Dr

Dallas, TX 75214

Home remodel, rear addition and five-bay garage planned

City of Dallas records describe a remodel and two-story rear addition to the single-family home, in a filing dated May 21, 2026. Plans call for 294 square feet of added space and a third bedroom above the kitchen extension. Later filings dated July 22 and October 8 describe a detached five-bay garage with carport extensions.

Summarized from City of Dallas records · updated Oct 8, 2026

Projects
7
7 filings
Latest filing
Oct 8, 2026
since May 21, 2026
Largest scope
—
Listed value
—

Permit & project history

7 projects
  1. No recorded plat- build a detached garage with 5 garage bays and a carport leanto on the left and right side of the structure. the lean to structures on the left and right will be gravel flooring not concrete slab. the detached garage will be approximately 75-100 feet away from the dwelling. the outside dimensions of the foundation for the structure will be 61'4 by 26'4. the foundation will be a 5" thick slab with #3 rebar at 12" o.c. a 12"x12" footer wall along the perimeter and at 15' intervals from left to right going from front to back for the width of the foundation. the leanto carport structures on the left and right side will be 24'8 total coverage from left to right and will be the same 26'4 depth as the garage structure. the structure will be made with 1/4" thick steel. 8" wall c channels. 8" ceiling ibeams going from front to back every 16" on centers.. 6" ibeam posts underneath the ceiling ibeams and at all 4 corners. the structure will have 5 garage bay doors 12' wide by 12' tall. 26 guage metal roof and wall panels. the structure will be insulated both in the wall and ceiling. there will be a 200 amp panel on the rear of the structure for any future car lifts, lights, and garage. once the structure and build site is approved i will order a building kit that will come with engineered stamped plans and i will submit those to the city as an additional plan set with this permit. i need to know the permit and build site will be approved before we spend 35k on a building kit. the building kit will be a bolt together kit engineered to the current and : that dallas has adopted

    No recorded plat- build a detached garage with 5 garage bays and a carport leanto on the left and right side of the structure. the lean to structures on the left and right will be gravel flooring not concrete slab. the detached garage will be approximately 75-100 feet away from the dwelling. the outside dimensions of the foundation for the structure will be 61'4 by 26'4. the foundation will be a 5" thick slab with #3 rebar at 12" o.c. a 12"x12" footer wall along the perimeter and at 15' intervals from left to right going from front to back for the width of the foundation. the leanto carport structures on the left and right side will be 24'8 total coverage from left to right and will be the same 26'4 depth as the garage structure. the structure will be made with 1/4" thick steel. 8" wall c channels. 8" ceiling ibeams going from front to back every 16" on centers.. 6" ibeam posts underneath the ceiling ibeams and at all 4 corners. the structure will have 5 garage bay doors 12' wide by 12' tall. 26 guage metal roof and wall panels. the structure will be insulated both in the wall and ceiling. there will be a 200 amp panel on the rear of the structure for any future car lifts, lights, and garage. once the structure and build site is approved i will order a building kit that will come with engineered stamped plans and i will submit those to the city as an additional plan set with this permit. i need to know the permit and build site will be approved before we spend 35k on a building kit. the building kit will be a bolt together kit engineered to the current and : that dallas has adopted

    City of Dallas permitResidential Alteration Addition Permit
    Record
    RES-ALT-ADD-26-001881
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  2. Nsfaa build a detached garage with 5 garage bays and a carport leanto on the left and right side of the structure. the detached garage will be approximately 75-100 feet away from the dwelling. the outside dimensions of the foundation for the structure will be 61'4 by 26'4. the foundation will be a 5" thick slab with #3 rebar at 12" o.c. a 12"x12" footer wall along the perimeter and at 15' intervals from left to right going from front to back for the width of the foundation. the leanto carport structures on the left and right side will be 24'8 total coverage from left to right and will be the same 26'4 depth as the garage structure. the structure will be made with 1/4" thick steel. 8" wall c channels. 12" ceiling ibeams going from front to back every 20'3" with 8" ceiling purlins going from left to right at a distance of 20'3". 6" ibeam posts underneath the ceiling ibeams and at all 4 corners. the structure will have 5 garage bay doors. 26 guage metal roof and wall panels. the structure will be insulated both in the wall and ceiling. there will be a 200 amp panel on the rear of the structure for any future car lifts, lights, and garage openers

    Nsfaa build a detached garage with 5 garage bays and a carport leanto on the left and right side of the structure. the detached garage will be approximately 75-100 feet away from the dwelling. the outside dimensions of the foundation for the structure will be 61'4 by 26'4. the foundation will be a 5" thick slab with #3 rebar at 12" o.c. a 12"x12" footer wall along the perimeter and at 15' intervals from left to right going from front to back for the width of the foundation. the leanto carport structures on the left and right side will be 24'8 total coverage from left to right and will be the same 26'4 depth as the garage structure. the structure will be made with 1/4" thick steel. 8" wall c channels. 12" ceiling ibeams going from front to back every 20'3" with 8" ceiling purlins going from left to right at a distance of 20'3". 6" ibeam posts underneath the ceiling ibeams and at all 4 corners. the structure will have 5 garage bay doors. 26 guage metal roof and wall panels. the structure will be insulated both in the wall and ceiling. there will be a 200 amp panel on the rear of the structure for any future car lifts, lights, and garage openers

    City of Dallas permitResidential Alteration Addition Permit
    Record
    RES-ALT-ADD-26-001398
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  3. Build a detached garage with 5 garage bays and a carport leanto on the left and right side of the structure. the outside dimensions of the foundation for the structure will be 61'4 by 26'4. the foundation will be a 5" thick slab with #3 rebar at 12" o.c. a 12"x12" footer wall along the perimeter and at 15' intervals from left to right going from front to back for the width of the foundation. the leanto carport structures on the left and right side will be 24'8 total coverage from left to right and will be the same 26'4 depth as the garage structure. the structure will be made with 1/4" thick steel. 8" wall c channels. 12" ceiling ibeams going from front to back every 20'3" with 8" ceiling purlins going from left to right at a distance of 20'3". 6" ibeam posts underneath the ceiling ibeams and at all 4 corners. the structure will have 5 garage bay doors. 26 guage metal roof and wall panels. the structure will be insulated both in the wall and ceiling. there will be a 200 amp panel on the rear of the structure for any future car lifts, lights, and garage openers

    Build a detached garage with 5 garage bays and a carport leanto on the left and right side of the structure. the outside dimensions of the foundation for the structure will be 61'4 by 26'4. the foundation will be a 5" thick slab with #3 rebar at 12" o.c. a 12"x12" footer wall along the perimeter and at 15' intervals from left to right going from front to back for the width of the foundation. the leanto carport structures on the left and right side will be 24'8 total coverage from left to right and will be the same 26'4 depth as the garage structure. the structure will be made with 1/4" thick steel. 8" wall c channels. 12" ceiling ibeams going from front to back every 20'3" with 8" ceiling purlins going from left to right at a distance of 20'3". 6" ibeam posts underneath the ceiling ibeams and at all 4 corners. the structure will have 5 garage bay doors. 26 guage metal roof and wall panels. the structure will be insulated both in the wall and ceiling. there will be a 200 amp panel on the rear of the structure for any future car lifts, lights, and garage openers

    City of Dallas permitResidential New Construction Permit
    Record
    RES-NEW-26-001315
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  4. Re-route ac ducting. the units are not being changed. the unit locations are not being changed. the air return locations are not being changed. only route the ac ducting in a new direction

    Re-route ac ducting. the units are not being changed. the unit locations are not being changed. the air return locations are not being changed. only route the ac ducting in a new direction

    City of Dallas permitResidential Mechanical Permit
    Record
    RES-MEC-26-003529
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  5. Kitchen sink is moved to new location in addition. master bathroom: move toilet, shower drain, bathtub drain, shower and bathtub valves, and move vanity. move washer and dryer from master bathroom to master closet. guest bath downstairs. move vanity and add urinal in bathroom. toilet stays in same spot. bathroom upstairs: toilet, vanity and bathtub stay in same location. add stackable washer and dryer. extend/move gas line in kitchen to opposite wall for new stove location

    Kitchen sink is moved to new location in addition. master bathroom: move toilet, shower drain, bathtub drain, shower and bathtub valves, and move vanity. move washer and dryer from master bathroom to master closet. guest bath downstairs. move vanity and add urinal in bathroom. toilet stays in same spot. bathroom upstairs: toilet, vanity and bathtub stay in same location. add stackable washer and dryer. extend/move gas line in kitchen to opposite wall for new stove location

    City of Dallas permitResidential Plumbing Permit
    Record
    RES-PLM-26-006118
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  6. Remove some switches and move to new location. replace all lighting with led can fixtures. add some cabinet lighting in master bathroom, hallway, and kitchen cabinetry. change ceiling fans for new fans in bedrooms. change ceiling fans on porch to chandeliers. trace wiring, replace any bad circuits if they exist

    Remove some switches and move to new location. replace all lighting with led can fixtures. add some cabinet lighting in master bathroom, hallway, and kitchen cabinetry. change ceiling fans for new fans in bedrooms. change ceiling fans on porch to chandeliers. trace wiring, replace any bad circuits if they exist

    City of Dallas permitResidential Electrical Permit
    Record
    RES-ELC-26-002992
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  7. Nsfaa this project consists of a partial foundation conversion, interior remodel, and rear addition to an existing two-story single-family residence.existing conditionsthe residence currently has:• a pier and beam foundation (with concrete footing walls) under the living room, office, hallway, hall bathroom, and master suite. • a slab-on-grade concrete foundation under the kitchen, dining room, and garage. • split floor elevations. there is a small step down between the kitchen down to the living room. there is an additional 3 steps from the hallway down to the master suite. foundation modifications• the existing pier and beam foundation under the living room, office, hallway, and hall bathroom will be removed and replaced with a slab-on-grade foundation. • new slab will be: o 4 inches thick o reinforced with rebar at 12" o.c. o supported by a 12" wide x 12" deep perimeter footing (interior foundation perimeter only inside the existing footing wall to create added support and structural strenght) • the existing exterior foundation/footings will remain unchanged. • the new slab elevation will be lowered to match the master bedroom floor elevation with steps up to the kitchen, front door, and sliding doors in living room. floor elevation changes• living room, office, hallway, and hall bath will be lowered. • a 3-step transition up will be created: o from living room to kitchen o toward the front entry with a landing at the front dooro along the front and side wall with new sliding doors • existing step-downs will be removed and replaced with new stepped transitions as described. structural modifications• removal of select load-bearing walls between kitchen, dining, and living areas. • installation of lvl beams per a stamped report by a licensed structural engineer. • replacement of portions of existing ceiling joists as required. openings & exterior modifications• living room: o remove one window and one side entry door o install two 12’ wide sliding glass doors • master bedroom: o remove existing bay window o install new sliding glass door • no other exterior modifications. addition (rear of home)• new two-story addition at rear of kitchen: o width: 16’-9” o depth: 8’-9” • total added area: o 147 sq ft (first floor) o 147 sq ft (second floor) second floor changes• addition of a third bedroom above the kitchen extension • new bedroom will include: o flat roof system with tpo roofing o designed to tie in below existing metal roof to avoid modification of existing roof structure • adding a few non load bearing walls to change the closets on the existing bedrooms and add a hallway with a bathroom entrance for the 3rd bedroom• existing bathroom will get updated but no changes to plumbing locations or layout will be required. interior modifications• hallway to master: o existing door removed o foundation modified to allow for new 8’–9’ tall door opening. with foundation being lowered we will cut out the footing wall at the door only to allow a taller door to be installed• master bathroom and closet: o finish upgrades only (no layout or plumbing relocation) • office, existing hall closets outside of powder room walls will be removed to create one big open floor plan. powder room will not change location, plumbing will keep the same locations. mep (mechanical, electrical, plumbing)• plumbing: no relocation • electrical: o replace existing lighting with led recessed fixtures o replace ceiling fans • hvac: o existing systems to remain o minor duct rerouting as needed for new layout roofing• no modifications to existing metal roof • addition will utilize a flat tpo roof system, installed below existing roofline to maintain drainage garage• no changes

    Nsfaa this project consists of a partial foundation conversion, interior remodel, and rear addition to an existing two-story single-family residence.existing conditionsthe residence currently has:• a pier and beam foundation (with concrete footing walls) under the living room, office, hallway, hall bathroom, and master suite. • a slab-on-grade concrete foundation under the kitchen, dining room, and garage. • split floor elevations. there is a small step down between the kitchen down to the living room. there is an additional 3 steps from the hallway down to the master suite. foundation modifications• the existing pier and beam foundation under the living room, office, hallway, and hall bathroom will be removed and replaced with a slab-on-grade foundation. • new slab will be: o 4 inches thick o reinforced with rebar at 12" o.c. o supported by a 12" wide x 12" deep perimeter footing (interior foundation perimeter only inside the existing footing wall to create added support and structural strenght) • the existing exterior foundation/footings will remain unchanged. • the new slab elevation will be lowered to match the master bedroom floor elevation with steps up to the kitchen, front door, and sliding doors in living room. floor elevation changes• living room, office, hallway, and hall bath will be lowered. • a 3-step transition up will be created: o from living room to kitchen o toward the front entry with a landing at the front dooro along the front and side wall with new sliding doors • existing step-downs will be removed and replaced with new stepped transitions as described. structural modifications• removal of select load-bearing walls between kitchen, dining, and living areas. • installation of lvl beams per a stamped report by a licensed structural engineer. • replacement of portions of existing ceiling joists as required. openings & exterior modifications• living room: o remove one window and one side entry door o install two 12’ wide sliding glass doors • master bedroom: o remove existing bay window o install new sliding glass door • no other exterior modifications. addition (rear of home)• new two-story addition at rear of kitchen: o width: 16’-9” o depth: 8’-9” • total added area: o 147 sq ft (first floor) o 147 sq ft (second floor) second floor changes• addition of a third bedroom above the kitchen extension • new bedroom will include: o flat roof system with tpo roofing o designed to tie in below existing metal roof to avoid modification of existing roof structure • adding a few non load bearing walls to change the closets on the existing bedrooms and add a hallway with a bathroom entrance for the 3rd bedroom• existing bathroom will get updated but no changes to plumbing locations or layout will be required. interior modifications• hallway to master: o existing door removed o foundation modified to allow for new 8’–9’ tall door opening. with foundation being lowered we will cut out the footing wall at the door only to allow a taller door to be installed• master bathroom and closet: o finish upgrades only (no layout or plumbing relocation) • office, existing hall closets outside of powder room walls will be removed to create one big open floor plan. powder room will not change location, plumbing will keep the same locations. mep (mechanical, electrical, plumbing)• plumbing: no relocation • electrical: o replace existing lighting with led recessed fixtures o replace ceiling fans • hvac: o existing systems to remain o minor duct rerouting as needed for new layout roofing• no modifications to existing metal roof • addition will utilize a flat tpo roof system, installed below existing roofline to maintain drainage garage• no changes

    City of Dallas permitResidential Alteration Addition Permit
    Record
    RES-ALT-ADD-26-000853
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro

Sources: City of Dallas

Questions about 4415 W Lawther Dr

What is being built at 4415 W Lawther Dr?

Dallas permit records describe a remodel and two-story rear addition to the existing home, along with plans for a detached five-bay garage with carport extensions. The records include filings from May 21 through October 8, 2026.

Is a new garage planned at 4415 W Lawther Dr?

Yes. Permit filings describe a detached garage with five bays and carport extensions on both sides. The plans appear in records dated July 22 and October 8, 2026; the latest filing is RES-ALT-ADD-26-001881.

How big is the home addition at 4415 W Lawther Dr?

The plans describe a two-story rear addition with 147 square feet on each floor, for 294 square feet total. The first filing is dated May 21, 2026, under permit RES-ALT-ADD-26-000853.

Will the addition at 4415 W Lawther Dr include a bedroom?

Yes. The plans describe a third bedroom above the kitchen extension, with a bathroom entrance from a new hallway.

When were permits filed for work at 4415 W Lawther Dr?

The earliest listed filing is dated May 21, 2026, for the home remodel and addition. The latest listed filing is dated October 8, 2026, for the detached garage.

Are the permits for 4415 W Lawther Dr approved?

The available records list filing dates and permit descriptions but do not include permit status, so they do not establish whether the permits were approved.

Also being built nearby

All of 75214

More offices in 75214, parking structures in 75214, restaurants in 75214.

Get alerts for 4415 W Lawther Dr