groundranger
Recent · latest filing Aug 2025Residential

6415 Axton Ln

Dallas, TX 75214

Structural repairs and restoration at 6415 Axton Ln

City of Dallas permits filed from June 14 to August 7, 2025, indicate foundation repairs and work to restore the home's structure after an earlier, uncompleted second-story addition. The listed work includes replacing structural beams, reinstalling ceiling joists, roof bracing, and updates to electrical, plumbing, and mechanical systems. The permit description says no new square footage is being added.

Summarized from City of Dallas records · updated Aug 7, 2025

Projects
5
5 filings
Latest filing
Aug 7, 2025
since Jun 14, 2025
Largest scope
—
Listed value
—

Permit & project history

5 projects
  1. New 5 ton system installation- electric

    New 5 ton system installation- electric

    City of Dallas permitResidential Mechanical Permit
    Record
    RES-MEC-25-001828
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  2. Gas releaseisland sanitary island waterlines

    Gas releaseisland sanitary island waterlines

    City of Dallas permitResidential Plumbing Permit
    Record
    RES-PLM-25-003295
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  3. Move oulets in kitchen area and add smoke detectors

    Move oulets in kitchen area and add smoke detectors

    City of Dallas permitResidential Electrical Permit
    Record
    RES-ELC-25-001897
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  4. Nsfaa-the property located at 6415 axton lane, dallas, texas, was recently acquired through a foreclosure sale. according to city records, the previous owner obtained permits to construct a second-story addition. however, construction of the addition was never started. the only work completed under the permit was limited to the removal of the living room ceiling, several roof rafters, and one interior wall in preparation for future framing that was never performed.the current scope of work is to restore the home to its original structural condition. the scope of work is from crosstown engineering's report.the proposed work includes:structural engineering oversight:beam #1: install (2) 1.75" x 16" lvl (versa-lam 2.1e or equivalent) in place of the previously removed beam. existing end supports are sufficient.beam #2: retain as-is. connect its left end to beam #1 using a simpson strong-tie hgus face-mounted hanger.beam #3: install (2) 2x12s laminated together. use the existing support at the left wall. at the right end, install a double 2x4 post atop beam #1 and reinforce with full-height 2x4s on each side of the two studs beneath.ceiling joists: reinstall existing 2x6 vaulted ceiling joists. replace any damaged joists with new 2x6 lumber.roof bracing: add mid-span bracing from the vaulted ceiling ridge to the existing front roof structure.gable wall: rebuild the gable-end wall over beam #1 using 2x4 studs spaced at 16" o.c. maximum.all lumber shall be douglas fir-larch (dfl) or southern yellow pine (syp), #2 grade or better.all metal connectors shall be simpson strong-tie or equivalent, using full fastening patterns and manufacturer-approved fasteners.no new square footage is being added. this project solely involves correcting and restoring previously removed structural elements to return the home to its original condition

    Nsfaa-the property located at 6415 axton lane, dallas, texas, was recently acquired through a foreclosure sale. according to city records, the previous owner obtained permits to construct a second-story addition. however, construction of the addition was never started. the only work completed under the permit was limited to the removal of the living room ceiling, several roof rafters, and one interior wall in preparation for future framing that was never performed.the current scope of work is to restore the home to its original structural condition. the scope of work is from crosstown engineering's report.the proposed work includes:structural engineering oversight:beam #1: install (2) 1.75" x 16" lvl (versa-lam 2.1e or equivalent) in place of the previously removed beam. existing end supports are sufficient.beam #2: retain as-is. connect its left end to beam #1 using a simpson strong-tie hgus face-mounted hanger.beam #3: install (2) 2x12s laminated together. use the existing support at the left wall. at the right end, install a double 2x4 post atop beam #1 and reinforce with full-height 2x4s on each side of the two studs beneath.ceiling joists: reinstall existing 2x6 vaulted ceiling joists. replace any damaged joists with new 2x6 lumber.roof bracing: add mid-span bracing from the vaulted ceiling ridge to the existing front roof structure.gable wall: rebuild the gable-end wall over beam #1 using 2x4 studs spaced at 16" o.c. maximum.all lumber shall be douglas fir-larch (dfl) or southern yellow pine (syp), #2 grade or better.all metal connectors shall be simpson strong-tie or equivalent, using full fastening patterns and manufacturer-approved fasteners.no new square footage is being added. this project solely involves correcting and restoring previously removed structural elements to return the home to its original condition

    City of Dallas permitResidential Alteration Addition Permit
    Record
    RES-ALT-ADD-25-000280
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  5. Adding exterior piers and adding sisters as recommended by the structural engineer

    Adding exterior piers and adding sisters as recommended by the structural engineer

    City of Dallas permitResidential Foundation Repair
    Record
    RES-FDN-25-000144
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro

Sources: City of Dallas

Questions about 6415 Axton Ln

What is being built at 6415 Axton Ln?

The permits indicate repairs and restoration to an existing home, not a new building. The listed structural work is intended to return the home to its original condition.

Is a second story being added at 6415 Axton Ln?

The July 23, 2025 permit description says an earlier second-story addition was never started. The current scope is to restore structural elements, with no new square footage being added.

What repairs are planned at 6415 Axton Ln?

The permit records include exterior piers and foundation work, beam and ceiling-joist repairs, roof bracing, and rebuilding a gable-end wall. They also list mechanical, plumbing, and electrical work.

When were permits filed for 6415 Axton Ln?

The earliest listed permit was filed June 14, 2025, for foundation repair (RES-FDN-25-000144). The latest was filed August 7, 2025, for a mechanical system installation (RES-MEC-25-001828).

Is new square footage being added at 6415 Axton Ln?

No. The description for permit RES-ALT-ADD-25-000280 says the work restores previously removed structural elements and adds no new square footage.

What does permit RES-ALT-ADD-25-000280 cover?

Filed July 23, 2025, the permit describes structural restoration, including beam replacement, reinstalling ceiling joists, roof bracing, and rebuilding a gable-end wall.

Also being built nearby

All of 75214

More restaurants in 75214.

Get alerts for 6415 Axton Ln