groundranger
Recent · latest filing May 2026Commercial

5974 W Northwest Hwy

Dallas, TX 75225

Restaurant planned in existing suite with 5,000-square-foot rooftop addition

A city permit filed January 28, 2025, describes an interior finish-out of an existing suite for a new restaurant, with a 5,000-square-foot rooftop addition. Later permits cover plumbing, electrical, and mechanical work, including circuits for an oven and ice machines. The records do not identify the restaurant.

Summarized from City of Dallas records · updated May 27, 2026

Projects
8
8 filings
Latest filing
May 27, 2026
since Jan 28, 2025
Largest scope
—
Listed value
$2.3M
partial · often understated

Permit & project history

8 projects
  1. Install water lines and backflow for new ice machines upstairs for craft

    Install water lines and backflow for new ice machines upstairs for craft

    City of Dallas permitCommercial Plumbing Permit
    Record
    COM-PLM-26-001926
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  2. 1. oven circuit — 480v / 3-phase / 60a? run new conduit and wire from the existing 480v electrical panel to the oven location? pull appropriately sized conductors (e.g., #6 thhn copper + ground) per necrequirements? install 60-amp, 3-pole fused disconnect at the oven? terminate all connections — line side and load side2. ice machine circuits (2) — 208v / 3-phase / 20a? provide and install transformer(s) to step down from 480v to 208v/3-phase ? run new conduit and wire from transformer(s) to each ice machine location? pull #12 thhn conductors for each 20-amp, 3-phase circuit? install disconnects at each ice machine location? terminate all connections at both ice machines3. transformer installation? transformer(s) to be ceiling-mounted on unistrut/support structure? 480v primary feed from existing panel to transformer(s)? all required conduit, wire, disconnects, and overcurrent protection on the primary side

    1. oven circuit — 480v / 3-phase / 60a? run new conduit and wire from the existing 480v electrical panel to the oven location? pull appropriately sized conductors (e.g., #6 thhn copper + ground) per necrequirements? install 60-amp, 3-pole fused disconnect at the oven? terminate all connections — line side and load side2. ice machine circuits (2) — 208v / 3-phase / 20a? provide and install transformer(s) to step down from 480v to 208v/3-phase ? run new conduit and wire from transformer(s) to each ice machine location? pull #12 thhn conductors for each 20-amp, 3-phase circuit? install disconnects at each ice machine location? terminate all connections at both ice machines3. transformer installation? transformer(s) to be ceiling-mounted on unistrut/support structure? 480v primary feed from existing panel to transformer(s)? all required conduit, wire, disconnects, and overcurrent protection on the primary side

    City of Dallas permitCommercial Electrical Permit
    Record
    COM-ELC-26-002219
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  3. (1) 4 ton split system unitassociated duct work(1) exhaust fan

    (1) 4 ton split system unitassociated duct work(1) exhaust fan

    City of Dallas permitCommercial Mechanical Permit
    Record
    COM-MEC-26-000370
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  4. This project is a full scale tenant finish out of an existing structure. the space had been previously occupied by a medical business, and will be converted to a restaurant. construction permit: 2501281125

    This project is a full scale tenant finish out of an existing structure. the space had been previously occupied by a medical business, and will be converted to a restaurant. construction permit: 2501281125

    City of Dallas permitCommercial Electrical Permit
    Record
    COM-ELC-25-001007
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  5. This project is a full scale tenant finish out of an existing structure. the space had been previously occupied by a medical business, and will be converted to a restaurant. construction permit: 2501281125

    This project is a full scale tenant finish out of an existing structure. the space had been previously occupied by a medical business, and will be converted to a restaurant. construction permit: 2501281125

    City of Dallas permitCommercial Electrical Permit
    Record
    COM-ELC-25-000941
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  6. Install new plumbing

    Install new plumbing

    City of Dallas permitCommercial Plumbing Permit
    Record
    COM-PLM-25-000835
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  7. Install new plumbing

    Install new plumbing

    City of Dallas permitCommercial Plumbing Permit
    Record
    COM-PLM-25-000839
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  8. Interior finish out of an existing suite to accommodate a new restaurant with a 5,000 sq ft rooftop addition

    Interior finish out of an existing suite to accommodate a new restaurant with a 5,000 sq ft rooftop addition

    City of Dallas permitCommercial Mechanical Permit$2.3M
    Record
    2501281124_197693483-002_ME_1
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro

Sources: City of Dallas

Questions about 5974 W Northwest Hwy

What is being built at 5974 W Northwest Hwy in Dallas?

A City of Dallas permit describes a restaurant finish-out in an existing suite with a 5,000-square-foot rooftop addition. The permit was filed January 28, 2025.

Is a new restaurant opening at 5974 W Northwest Hwy?

City permit records describe converting a space previously occupied by a medical business into a restaurant. The records do not name the restaurant or state an opening date.

When was the restaurant project at 5974 W Northwest Hwy permitted?

The mechanical permit for the interior finish-out and rooftop addition was filed January 28, 2025. The permit number is 2501281124_197693483-002_ME_1.

What work is happening at 5974 W Northwest Hwy in 2026?

Dallas permits filed in February and May 2026 cover a split-system unit and exhaust fan, oven and ice-machine electrical work, and water lines and backflow for upstairs ice machines. The records do not say whether the restaurant is open.

What is the name of the restaurant at 5974 W Northwest Hwy?

The City of Dallas permit records provided describe a new restaurant but do not list its name.

Also being built nearby

All of 75225

More medical facilities in 75225, new homes in 75225, restaurants in 75225.

Get alerts for 5974 W Northwest Hwy