5974 W Northwest Hwy
Dallas, TX 75225
Restaurant planned in existing suite with 5,000-square-foot rooftop addition
A city permit filed January 28, 2025, describes an interior finish-out of an existing suite for a new restaurant, with a 5,000-square-foot rooftop addition. Later permits cover plumbing, electrical, and mechanical work, including circuits for an oven and ice machines. The records do not identify the restaurant.
Summarized from City of Dallas records · updated May 27, 2026
- Projects
- 8
- 8 filings
- Latest filing
- May 27, 2026
- since Jan 28, 2025
- Largest scope
- —
- Listed value
- $2.3M
- partial · often understated
Permit & project history
8 projects1. oven circuit — 480v / 3-phase / 60a? run new conduit and wire from the existing 480v electrical panel to the oven location? pull appropriately sized conductors (e.g., #6 thhn copper + ground) per necrequirements? install 60-amp, 3-pole fused disconnect at the oven? terminate all connections — line side and load side2. ice machine circuits (2) — 208v / 3-phase / 20a? provide and install transformer(s) to step down from 480v to 208v/3-phase ? run new conduit and wire from transformer(s) to each ice machine location? pull #12 thhn conductors for each 20-amp, 3-phase circuit? install disconnects at each ice machine location? terminate all connections at both ice machines3. transformer installation? transformer(s) to be ceiling-mounted on unistrut/support structure? 480v primary feed from existing panel to transformer(s)? all required conduit, wire, disconnects, and overcurrent protection on the primary side
1. oven circuit — 480v / 3-phase / 60a? run new conduit and wire from the existing 480v electrical panel to the oven location? pull appropriately sized conductors (e.g., #6 thhn copper + ground) per necrequirements? install 60-amp, 3-pole fused disconnect at the oven? terminate all connections — line side and load side2. ice machine circuits (2) — 208v / 3-phase / 20a? provide and install transformer(s) to step down from 480v to 208v/3-phase ? run new conduit and wire from transformer(s) to each ice machine location? pull #12 thhn conductors for each 20-amp, 3-phase circuit? install disconnects at each ice machine location? terminate all connections at both ice machines3. transformer installation? transformer(s) to be ceiling-mounted on unistrut/support structure? 480v primary feed from existing panel to transformer(s)? all required conduit, wire, disconnects, and overcurrent protection on the primary side
City of Dallas permitCommercial Electrical PermitThis project is a full scale tenant finish out of an existing structure. the space had been previously occupied by a medical business, and will be converted to a restaurant. construction permit: 2501281125
This project is a full scale tenant finish out of an existing structure. the space had been previously occupied by a medical business, and will be converted to a restaurant. construction permit: 2501281125
City of Dallas permitCommercial Electrical PermitThis project is a full scale tenant finish out of an existing structure. the space had been previously occupied by a medical business, and will be converted to a restaurant. construction permit: 2501281125
This project is a full scale tenant finish out of an existing structure. the space had been previously occupied by a medical business, and will be converted to a restaurant. construction permit: 2501281125
City of Dallas permitCommercial Electrical PermitInterior finish out of an existing suite to accommodate a new restaurant with a 5,000 sq ft rooftop addition
Interior finish out of an existing suite to accommodate a new restaurant with a 5,000 sq ft rooftop addition
City of Dallas permitCommercial Mechanical Permit$2.3M
Sources: City of Dallas
Questions about 5974 W Northwest Hwy
What is being built at 5974 W Northwest Hwy in Dallas?
A City of Dallas permit describes a restaurant finish-out in an existing suite with a 5,000-square-foot rooftop addition. The permit was filed January 28, 2025.
Is a new restaurant opening at 5974 W Northwest Hwy?
City permit records describe converting a space previously occupied by a medical business into a restaurant. The records do not name the restaurant or state an opening date.
When was the restaurant project at 5974 W Northwest Hwy permitted?
The mechanical permit for the interior finish-out and rooftop addition was filed January 28, 2025. The permit number is 2501281124_197693483-002_ME_1.
What work is happening at 5974 W Northwest Hwy in 2026?
Dallas permits filed in February and May 2026 cover a split-system unit and exhaust fan, oven and ice-machine electrical work, and water lines and backflow for upstairs ice machines. The records do not say whether the restaurant is open.
What is the name of the restaurant at 5974 W Northwest Hwy?
The City of Dallas permit records provided describe a new restaurant but do not list its name.
Also being built nearby
All of 75225- 5964 W Northwest HwyDec 18, 2025Mcr landlord improvement. parapet permit · 15 m away
- 5962 W Northwest HwyDec 31, 2025Install new meter base and transocket due to construction project in adjacent suite · 28 m away
- 5944 W Northwest HwyJul 21, 2025Clean and show permit only · 49 m away
- 6130 Berkshire Ln · Kate Luther LPMar 13, 202455 seventy commercial buildout expansion — renovation/alteration — interior remodel of existing space to become addition of space for existing private club, 55 seventy · 66 m away
- 6124 Berkshire LnNov 7, 2025Gas test “ · 72 m away
- 6109 Berkshire LnFeb 18, 2026No work · 81 m away
- 8421 Westchester Dr · Kinney Property F&p, Ltd. And Willingham Property Co.Aug 20, 2024The po boy shop — renovation/alteration — altering an existing restaurant into a different restaurant. mostly replacing finishes and equipment · 99 m away
- 5938 W Northwest Hwy · Kinney Property F&p Ltd & Willingham Property CoNov 2, 2026Zo bc a 1,037 sq ft phine vietnamese coffee shop · 116 m away
- 8411 Preston Road · Dallas Berkshire Partners LtdOct 29, 2026Preston financial center entry canopy — renovation/alteration — remove existing canopy and replace with new canopy and vestibule · 139 m away
- 8411 Preston Rd · Dallas Berkshire Partners LtdAug 27, 2026Zo bc altering appearance of 1st and 2nd level lobby, adding canopy at front entrance · 139 m away
- 8335 Westchester Dr · Alpine Preston Center Pavilion LPNov 12, 20261. extend 4" insulated chilled water piping from exis,ng loca,on to tenant space2. provide and install (4) new exhaust fans3. provide and install (4) new louvers4. provide and install black iron grease exhaust duct, stainless dishwasher exhaust duct andgalvanized restroom exhaust duct according to smacna hvac duct construc,on standards5. provide and install double layer fire wrap for grease exhaust duct6. provide all required saw cu9ng and core drilling of concrete7. provide all shipping, rigging and hois,ng8. startup and check opera,on of new systems · 158 m away
- 6033 Berkshire LnNov 17, 2026Interior remodel existing service plugs lights · 165 m away