10112 Gooding Dr
Dallas, TX 75229
Electrical upgrade and foundation repair at 10112 Gooding Dr
City of Dallas permits indicate residential foundation repair and an electrical service upgrade at 10112 Gooding Dr. The foundation repair was filed on October 22, 2025, and the electrical upgrade on February 2, 2026.
Summarized from City of Dallas records · updated Feb 2, 2026
- Projects
- 5
- 5 filings
- Latest filing
- Feb 2, 2026
- since Oct 22, 2025
- Largest scope
- —
- Listed value
- —
Permit & project history
5 projectsIt is recommended that four (4) piers be installed as indicated in the figure(s) a ached to this report. it is also recommended that the floor be releveled, and any existing internal supports be re-shimmed with steel shims
It is recommended that four (4) piers be installed as indicated in the figure(s) a ached to this report. it is also recommended that the floor be releveled, and any existing internal supports be re-shimmed with steel shims
City of Dallas permitResidential Foundation Repair
Sources: City of Dallas
Questions about 10112 Gooding Dr
What is being built at 10112 Gooding Dr?
City of Dallas records show residential repairs: foundation work and an electrical service upgrade. The records do not describe a new building.
What foundation work is planned at 10112 Gooding Dr?
A permit filed October 22, 2025, recommends installing four piers, releveling the floor, and reshiming existing internal supports with steel shims. The permit number is RES-FDN-25-000599.
Was an electrical permit filed for 10112 Gooding Dr?
Yes. The City of Dallas recorded a residential electrical permit for an electrical service upgrade on February 2, 2026. The permit number is RES-ELC-26-000555.
When was the latest permit filed at 10112 Gooding Dr?
The latest listed filing is an electrical service upgrade permit dated February 2, 2026.
Have there been other permits at 10112 Gooding Dr?
Yes. City records also list general repairs in July 2020 and electrical repairs in February 2020, along with electrical work filed in November 2019.
Also being built nearby
All of 75229- 4051 Killion DrJan 23, 2026X1 50 gal gas water heater in the interior closet · 98 m away
- 4126 Killion DrJul 15, 2026Gas pressure test · 153 m away
- 10050 Gooding DrSep 18, 2025Install new 8ft tall fence with 3 gates df cedar pickets and metal post everything stained · 165 m away
- 4074 South Better DrSep 22, 2025Install a cedar wood board on board fence not to exceed 9' in height with 3 gates and 1 wrought iron motorized gate. gate and fence in front yard will not be over 4' in height. fence does not cross utility easement · 168 m away
- 10215 Gooding DrMar 2, 2026Overhead reroute · 181 m away
- 4027 Killion DrOct 5, 2026Install 8ft perimeter fence · 195 m away
- 4137 Walnut Glen PlJun 4, 2026Install 50 gallon gas water heater in attic (swap out) · 199 m away
- 4118 Walnut GlenDec 10, 2025New plumbing · 203 m away
- 4118 Walnut Glen PlNov 26, 2025New electrical wiring · 203 m away
- 4148 Walnut Glen PlJun 8, 2026Repaired sewer under the house · 214 m away
- 10223 Better DrNov 18, 2026* create a new garage door opening approximately 21’ wide × 7’ high, subject to final field verification and approvedengineering requirements.* perform the necessary demolition and structural modifications to the existing exterior wall.* provide temporary structural support as required during construction.* furnish and install the necessary lvl header beam, structural framing, columns, reinforcement, anchors, andconnections according to the approved engineering plans.patio cover new covered patio with an approximately 20’ × 20’ structural footprint.* furnish and install necessary structural framing, support posts, lvl beams, rafters, ceiling joists, blocking,anchors, and structural connections according to the approved engineering plans.* install required concrete foundations and structural supports as specified by the approved plans.* construct the new gable-style roof with an approximately 4:12 pitch, as shown in the approved design.* include approximately 2’6” roof overhangs where indicated by the plans.* complete necessary structural connections and reinforcement where the new patio roof attaches to the existing house · 220 m away
- 4021 Killion DrAug 28, 2025Phase 1- rough in* relocate ice maker box* cap gas line under sub floor* relocate and plumb in kitchen sink from current location to underneath kitchen window. includes water lines and drain line. we will connect to existing vent.* new water lines will be insulated as required by code · 221 m away