groundranger
Recent · latest filing May 2026Residential

4170 Meadowdale Ln

Dallas, TX 75229

4170 Meadowdale Ln home renovation

City of Dallas permits indicate a complete renovation of the existing residence at 4170 Meadowdale Ln. The renovation was permitted on January 7, 2026, with additional electrical, mechanical and plumbing permits filed through May 28, 2026.

Summarized from City of Dallas records · updated May 28, 2026

Projects
6
6 filings
Latest filing
May 28, 2026
since Jan 7, 2026
Largest scope
—
Listed value
—

Permit & project history

6 projects
  1. 2 toilets, 2 baths sinks, 2 standup showers, 1 kitchen sink, 1 washer and 1 tankless water heater

    2 toilets, 2 baths sinks, 2 standup showers, 1 kitchen sink, 1 washer and 1 tankless water heater

    City of Dallas permitResidential Plumbing Permit
    Record
    RES-PLM-26-005485
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  2. Install a new air conditioning and heating system including ductwork

    Install a new air conditioning and heating system including ductwork

    City of Dallas permitResidential Mechanical Permit
    Record
    RES-MEC-26-000685
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  3. Re-place all wiring, wiring devices, up grade panel to 200 amps and re-locate

    Re-place all wiring, wiring devices, up grade panel to 200 amps and re-locate

    City of Dallas permitResidential Electrical Permit
    Record
    RES-ELC-26-000536
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  4. Tankless water heater installation. work to include replacement of tank water heater with a company provided navien (model no. npe-240a2 - this model does have a built-in circulation pump) tankless water heater, new drain pan, gas sediment trap, new gas flex line, new cold water valve manifold, new hot water valve manifold, new gas shut-off valve, carbon monoxide detector, condensation neutralizer, and haul-off and disposal of the existing tank water heater. work includes subcontracting a roofer to repair one roof penetration. all work permitted and inspected through the city. scope of work: work includes moving the fireplace shut off valves roughly 10 inches to the rightscope of work: work includes removing the stub out for the overnight and stubbing up a few inches away with 2 separate shut off valves work includes shortening down the gas line entering the attic for the purpose of drain pan being able to fit under the hvac unit. the 3/4 line would split into 2 shut off valves for both the hvac unit and the tankless. work includes the removal of 2 copper drain lines and rebuilding with pvc. work also includes removing broken galvanized vent and replacing with pvc. removing 9 visible sharkbite fittings , 6 behind the right side bathroom vanity, 2 behind right side bathroom toilet and 1 behind left toilet. replacing with copper or compression fittings work includes removing old copper drain lines and replacing them with schedule 40 pvc using different pipe sizes and various fittings

    Tankless water heater installation. work to include replacement of tank water heater with a company provided navien (model no. npe-240a2 - this model does have a built-in circulation pump) tankless water heater, new drain pan, gas sediment trap, new gas flex line, new cold water valve manifold, new hot water valve manifold, new gas shut-off valve, carbon monoxide detector, condensation neutralizer, and haul-off and disposal of the existing tank water heater. work includes subcontracting a roofer to repair one roof penetration. all work permitted and inspected through the city. scope of work: work includes moving the fireplace shut off valves roughly 10 inches to the rightscope of work: work includes removing the stub out for the overnight and stubbing up a few inches away with 2 separate shut off valves work includes shortening down the gas line entering the attic for the purpose of drain pan being able to fit under the hvac unit. the 3/4 line would split into 2 shut off valves for both the hvac unit and the tankless. work includes the removal of 2 copper drain lines and rebuilding with pvc. work also includes removing broken galvanized vent and replacing with pvc. removing 9 visible sharkbite fittings , 6 behind the right side bathroom vanity, 2 behind right side bathroom toilet and 1 behind left toilet. replacing with copper or compression fittings work includes removing old copper drain lines and replacing them with schedule 40 pvc using different pipe sizes and various fittings

    City of Dallas permitResidential Plumbing Permit
    Record
    RES-PLM-26-000941
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  5. Work is a complete renovation of existing residence

    Work is a complete renovation of existing residence

    City of Dallas permitResidential Alteration Addition Permit
    Record
    RES-ALT-ADD-26-000041
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  6. Work is a complete renovation of existing 72 year old residence. existing gypsum wallboard will be removed from walls and ceilings. existing flooring will be removed to subfloor. existing aluminum wiring and 125a panelboard will be removed. existing domestic water will be replaced above floor level. existing sanitary sewer piping will be replaced above and below floor in kitchen, bathrooms and living room bar area. new code compliant copper wiring and new 200 a panelboard will be installed by a licensed electrician. new 200 a service to residence will be replace existing 125 a service by licensed electrician in coordination with the electrical utility company. new led spot lighting will be installed in all rooms by licensed electrician. existing hvac system will be replaced complete with new 17 seer 5 ton multi-speed hvac unit, distribution ductwork and grilles by licensed mechanical contractor. new r18 insulation will be placed complete in walls and new r32 insulation will be placed in ceiling. new 6.5mm radiant barrier foil insulation will be installed inside roof sheathing throughout. new gypsum board walls and ceilings will be installed. new porcelan tile will be installed over hardibacker floor insulation. new energy compliant windows and doors will be installed. a 50a electric vehicle charging receptacle will be installed in the garage by a licensed electrician. new energy efficient appliances will be installed in kitchen and living room bar area. new fume hoods and exhaust ducting will be installed over appliances by licensed mechanical contractor

    Work is a complete renovation of existing 72 year old residence. existing gypsum wallboard will be removed from walls and ceilings. existing flooring will be removed to subfloor. existing aluminum wiring and 125a panelboard will be removed. existing domestic water will be replaced above floor level. existing sanitary sewer piping will be replaced above and below floor in kitchen, bathrooms and living room bar area. new code compliant copper wiring and new 200 a panelboard will be installed by a licensed electrician. new 200 a service to residence will be replace existing 125 a service by licensed electrician in coordination with the electrical utility company. new led spot lighting will be installed in all rooms by licensed electrician. existing hvac system will be replaced complete with new 17 seer 5 ton multi-speed hvac unit, distribution ductwork and grilles by licensed mechanical contractor. new r18 insulation will be placed complete in walls and new r32 insulation will be placed in ceiling. new 6.5mm radiant barrier foil insulation will be installed inside roof sheathing throughout. new gypsum board walls and ceilings will be installed. new porcelan tile will be installed over hardibacker floor insulation. new energy compliant windows and doors will be installed. a 50a electric vehicle charging receptacle will be installed in the garage by a licensed electrician. new energy efficient appliances will be installed in kitchen and living room bar area. new fume hoods and exhaust ducting will be installed over appliances by licensed mechanical contractor

    City of Dallas permitResidential New Construction Permit
    Record
    RES-NEW-26-000019
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro

Sources: City of Dallas

Questions about 4170 Meadowdale Ln

What is being built at 4170 Meadowdale Ln?

City of Dallas permit records describe a complete renovation of the existing residence, not a new building. The initial permit, RES-NEW-26-000019, was filed January 7, 2026.

When was the renovation at 4170 Meadowdale Ln permitted?

The initial renovation permit was filed January 7, 2026. Additional permits were filed through May 28, 2026.

What work is included in the renovation at 4170 Meadowdale Ln?

The initial permit describes replacement of wiring, plumbing, HVAC, insulation, windows and doors, plus interior finish work. It also lists a 50-amp electric vehicle charging receptacle and kitchen and living-room bar appliances.

Are new electrical and HVAC systems being installed at 4170 Meadowdale Ln?

Yes. Permits describe replacement wiring and an upgrade to a 200-amp panel, along with a new heating and air-conditioning system and ductwork. The electrical permit is RES-ELC-26-000536, filed January 31, 2026; the mechanical permit is RES-MEC-26-000685, filed February 19, 2026.

What plumbing work is permitted at 4170 Meadowdale Ln?

The records include plumbing work for a tankless water heater and later-listed fixtures, including toilets, bathroom sinks, showers, a kitchen sink and a washer. The latest listed plumbing permit, RES-PLM-26-005485, was filed May 28, 2026.

Also being built nearby

All of 75229

More warehouses & industrial in 75229, restaurants in 75229.

Get alerts for 4170 Meadowdale Ln