4527 N Lindhurst Ave
Dallas, TX 75229
Permits cover a cabana, outdoor shower and sports court
City of Dallas permits filed from April through October 2026 cover a cabana addition, outdoor shower and sports court at 4527 N Lindhurst Ave. Later filings also cover cabana HVAC, electrical work, gas lines and a generator installation.
Summarized from City of Dallas records · updated Oct 30, 2026
- Projects
- 8
- 8 filings
- Latest filing
- Oct 30, 2026
- since Apr 9, 2026
- Largest scope
- —
- Listed value
- —
Permit & project history
8 projectsRelocate and upgrade electrical service from 320 amp to 600 amptench, conduit, wire from new service to existing electrical panels in garage
Relocate and upgrade electrical service from 320 amp to 600 amptench, conduit, wire from new service to existing electrical panels in garage
City of Dallas permitResidential Electrical PermitRough phase:1. hand trench and install 45' of 1" gas poly from existing gas meter medium supply to generator location.2. hand trench and install 80' of 1" gas poly from existing pool heater medium supply to storage closet at rear of cabana. 3. hand trench and install 50' of 1" gas poly from low pressure side of cabana riser to fire pit location, under new steps. 4. hand trench and install 50' of 1" gas poly from low pressure side of cabana riser to retaining wall location at bbq. 5. install 1" isolation ball valve and union at gas main connections at meter and pool heater, and at storage closet riser to new appliances for future isolation and testing.6. test new gas service lines for city inspection and backfill after approval.7. install 2" pvc sleeve with long sweep from storage closet to side of sunken fireplace and cap ends.8. install 2" pvc sleeve with long sweep from rear of retaining wall to side of sunken bbq and cap ends.top out phase:1. install 1/2" csst through pvc sleeves 20' to bbq and 5' to fireplace.2. install fireplace klye valve and log lighter.3. install fire pit klye valve and connect to custom log lighter provided by others.4. retest gas piping for city inspection.5. seal pvc sleeves around csst piping.trim phase:1. trim out fireplace and fire pit klye valves, cut log lighters as needed.2. install 1" iso valve, med/low regulator, and flex (provided by others) at generator. 3. install 1" med/low regulator at cabana gas riser manifold with 1" union.4. install 1/2" ball valve with plug at bbq, appliance connector provided by others.5. retest gas piping for city ispection.6. remove gas gauges after city approval, fire up and test all appliances
Rough phase:1. hand trench and install 45' of 1" gas poly from existing gas meter medium supply to generator location.2. hand trench and install 80' of 1" gas poly from existing pool heater medium supply to storage closet at rear of cabana. 3. hand trench and install 50' of 1" gas poly from low pressure side of cabana riser to fire pit location, under new steps. 4. hand trench and install 50' of 1" gas poly from low pressure side of cabana riser to retaining wall location at bbq. 5. install 1" isolation ball valve and union at gas main connections at meter and pool heater, and at storage closet riser to new appliances for future isolation and testing.6. test new gas service lines for city inspection and backfill after approval.7. install 2" pvc sleeve with long sweep from storage closet to side of sunken fireplace and cap ends.8. install 2" pvc sleeve with long sweep from rear of retaining wall to side of sunken bbq and cap ends.top out phase:1. install 1/2" csst through pvc sleeves 20' to bbq and 5' to fireplace.2. install fireplace klye valve and log lighter.3. install fire pit klye valve and connect to custom log lighter provided by others.4. retest gas piping for city inspection.5. seal pvc sleeves around csst piping.trim phase:1. trim out fireplace and fire pit klye valves, cut log lighters as needed.2. install 1" iso valve, med/low regulator, and flex (provided by others) at generator. 3. install 1" med/low regulator at cabana gas riser manifold with 1" union.4. install 1/2" ball valve with plug at bbq, appliance connector provided by others.5. retest gas piping for city ispection.6. remove gas gauges after city approval, fire up and test all appliances
City of Dallas permitResidential Plumbing Permit
Sources: City of Dallas
Questions about 4527 N Lindhurst Ave
What is being built at 4527 N Lindhurst Ave?
Dallas permits cover a cabana addition, outdoor shower and sports court. The filings also include related electrical, plumbing and mechanical work.
When was the cabana addition permitted at 4527 N Lindhurst Ave?
The City of Dallas filed permit RES-ALT-ADD-26-000600 for a cabana addition on April 9, 2026.
Is there a new sports court planned at 4527 N Lindhurst Ave?
A Dallas residential alteration and addition permit filed October 13, 2026, describes an outdoor shower addition and sports court. The permit number is RES-ALT-ADD-26-001846.
Is a generator being installed at 4527 N Lindhurst Ave?
Dallas filed a residential electrical permit for a generator installation on October 30, 2026. A related plumbing permit filed October 22 covers gas for the generator.
What other work is permitted at 4527 N Lindhurst Ave?
Records include cabana HVAC work filed August 12, 2026, and electrical work for a detached structure filed June 1. A May 7 plumbing permit describes gas lines for the generator, cabana, barbecue and fire features.
Also being built nearby
All of 75229- 4507 N Lindhurst AveJul 13, 2026Building new screening walls & drive gates in front yard · 22 m away
- 4611 N Lindhurst AveNov 23, 2020Backup generator · 94 m away
- 10218 Woodford DrDec 5, 2025Foundation repair-shim & encapsulate 2366sqft and replace 69' of wood · 167 m away
- 10204 Woodford DrApr 4, 2024Addition · 183 m away
- 4706 N Lindhurst AveMay 28, 2025Replacing gas tankless water heater with a 40 gallon gas water heater · 209 m away
- 10036 Rock Hill LnOct 18, 2025Installed two 50 gallon gas water heaters in second floor walk in attic · 217 m away
- 4627 Dorset RdDec 9, 2020Tc-2020-25975 12/4/2020 · 230 m away
- 10214 Epping LnOct 2, 2026Electrical work for new residential · 239 m away
- 10024 Rock Hill LnMar 13, 20264 ton standard plus - “performance series 2stage” gas system · 253 m away
- 10224 Epping LnMar 10, 2026Tearoff and dispose existing metal roof and replace with like kind · 254 m away
- 4715 S Lindhurst AveOct 16, 2026Remove old composition shingles & install new composition shingles · 258 m away
- 10023 Rock Hill LnSep 16, 2025Reprovision existing circuit for new pergolas, one fan and two can lights · 261 m away