groundranger
Recent · latest filing Sep 2025Residential

4830 Crooked Ln

Dallas, TX 75229

Fence, generator and pool plumbing permits at 4830 Crooked Ln

Dallas permits indicate work at this residential property includes cedar fencing, a 26-kilowatt generator and a pool heater connection. The first permit was filed June 25, 2025, and the latest was filed September 5, 2025.

Summarized from City of Dallas records · updated Sep 5, 2025

Projects
4
4 filings
Latest filing
Sep 5, 2025
since Jun 25, 2025
Largest scope
—
Listed value
—

Permit & project history

4 projects
  1. Ptrap and pool heater connection

    Ptrap and pool heater connection

    City of Dallas permitResidential Plumbing Permit
    Record
    RES-PLM-25-004550
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  2. Installation of a residential 26kw generac generator, the builder is running the gas line from gas meter to generator. we are just hooking up to that line

    Installation of a residential 26kw generac generator, the builder is running the gas line from gas meter to generator. we are just hooking up to that line

    City of Dallas permitResidential Plumbing Permit
    Record
    RES-PLM-25-003486
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  3. Installation of a residential 26kw generac generator

    Installation of a residential 26kw generac generator

    City of Dallas permitResidential Electrical Permit
    Record
    RES-ELC-25-001570
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  4. Main fence – 8' horizontal board-on-board cedar (350 lf)installation of 350 linear feet of 8-foot horizontal board-on-board western red cedar fencing. fence will be constructed using 2?" diameter,.095 wall, 13-gauge galvanized steel posts, set 36 inches deep in 8-inch diameter holes with 5500 psi concrete on 6-foot centers. includes 2x4 cedar rails and 1x6 cedar pickets, fastened with galvanized ring shank nails.finishing details include a 2x6 treated pine baseboard, 2x6 cedar cap, and 1x4 vertical trim every 8 feet.also includes:(2) 4-foot pedestrian gates, each built with a 2-inch galvanized steel frame and mounted on 4x4 galvanized steel posts with standard latches.(40) post boxes along the alley and northwest front section.east/return to garage – orange (154 lf)installation of 154 linear feet of 8-foot horizontal board-on-board western red cedar fencing, matching the construction specifications described above.this section also includes double-faced fencing along the entire length, for a clean finish on both sides.includes:(1) 4-foot pedestrian gate with galvanized steel frame and standard hardware.ne side/front – green (110 lf)installation of 110 linear feet of 8-foot horizontal board-on-board western red cedar fencing, built to the same specs.includes:full double-face fencing along the length for a consistent appearance on both sides.(1) 4-foot pedestrian gate with a galvanized steel frame and standard latch.auto slide gate – blue (1 gate, 8'x24')installation of one 8-foot tall by 24-foot wide automatic slide gate with galvanized steel frame. includes:motorized operator systemsafety eye sensortwo remote controlswireless keypad for secure, convenient entry

    Main fence – 8' horizontal board-on-board cedar (350 lf)installation of 350 linear feet of 8-foot horizontal board-on-board western red cedar fencing. fence will be constructed using 2?" diameter,.095 wall, 13-gauge galvanized steel posts, set 36 inches deep in 8-inch diameter holes with 5500 psi concrete on 6-foot centers. includes 2x4 cedar rails and 1x6 cedar pickets, fastened with galvanized ring shank nails.finishing details include a 2x6 treated pine baseboard, 2x6 cedar cap, and 1x4 vertical trim every 8 feet.also includes:(2) 4-foot pedestrian gates, each built with a 2-inch galvanized steel frame and mounted on 4x4 galvanized steel posts with standard latches.(40) post boxes along the alley and northwest front section.east/return to garage – orange (154 lf)installation of 154 linear feet of 8-foot horizontal board-on-board western red cedar fencing, matching the construction specifications described above.this section also includes double-faced fencing along the entire length, for a clean finish on both sides.includes:(1) 4-foot pedestrian gate with galvanized steel frame and standard hardware.ne side/front – green (110 lf)installation of 110 linear feet of 8-foot horizontal board-on-board western red cedar fencing, built to the same specs.includes:full double-face fencing along the length for a consistent appearance on both sides.(1) 4-foot pedestrian gate with a galvanized steel frame and standard latch.auto slide gate – blue (1 gate, 8'x24')installation of one 8-foot tall by 24-foot wide automatic slide gate with galvanized steel frame. includes:motorized operator systemsafety eye sensortwo remote controlswireless keypad for secure, convenient entry

    City of Dallas permitResidential Accessory Structure Permit
    Record
    RES-ACC-25-000169
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro

Sources: City of Dallas

Questions about 4830 Crooked Ln

What work is permitted at 4830 Crooked Ln in Dallas?

Dallas records show permits for fencing, a residential generator and pool plumbing. The filings date from June 25 to September 5, 2025.

Is a new house being built at 4830 Crooked Ln?

The records provided show residential permits for fencing, a generator and pool plumbing, not a permit for a new house.

What kind of fence is planned at 4830 Crooked Ln?

Permit RES-ACC-25-000169, filed June 25, 2025, describes 8-foot horizontal board-on-board cedar fencing and an 8-by-24-foot automatic slide gate.

Is a generator being installed at 4830 Crooked Ln?

Yes. Dallas permits filed July 29 and August 11, 2025, describe installation of a residential 26-kilowatt Generac generator.

What pool work is permitted at 4830 Crooked Ln?

Permit RES-PLM-25-004550, filed September 5, 2025, describes a P-trap and pool heater connection.

Also being built nearby

All of 75229

More pools in 75229.

Get alerts for 4830 Crooked Ln