groundranger
Active · latest filing Nov 2026Residential

5307 Denton Dr

Dallas, TX 75235

Home renovations and roof replacement at 5307 Denton Dr

City of Dallas permits filed in May 2026 indicate roof reconstruction and a patio-to-garage conversion at an existing home at 5307 Denton Dr. Additional permits through November cover electrical, HVAC and plumbing work, including a bathroom shower upgrade and water heater.

Summarized from City of Dallas records · updated Nov 6, 2026

Projects
6
6 filings
Latest filing
Nov 6, 2026
since May 8, 2026
Largest scope
—
Listed value
—

Permit & project history

6 projects
  1. I am a homeowner with one house under a homestead exemption. i am pulling a plumbing permit to cover a bathroom shower upgrade, new water heater, and related plumbing alterations

    I am a homeowner with one house under a homestead exemption. i am pulling a plumbing permit to cover a bathroom shower upgrade, new water heater, and related plumbing alterations

    City of Dallas permitResidential Plumbing Permit
    Record
    RES-PLM-26-011832
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  2. As part of my home's existing framing all application res-alt-add-26-000861, i am creating the mechanical application for hvac work. under this alteration addition permit, i have already been inspected once in which i was given notice that "framing all ok pending mechanicals". now, i'm trying to complete my mechanicals. the scope of this permit is all heating and cooling mechanical needs for the residence

    As part of my home's existing framing all application res-alt-add-26-000861, i am creating the mechanical application for hvac work. under this alteration addition permit, i have already been inspected once in which i was given notice that "framing all ok pending mechanicals". now, i'm trying to complete my mechanicals. the scope of this permit is all heating and cooling mechanical needs for the residence

    City of Dallas permitResidential Mechanical Permit
    Record
    RES-MEC-26-005693
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  3. Complete electrical rewire of existing 1,600 sq ft single-family residence. scope includes replacement of existing branch-circuit wiring; installation of code-compliant receptacle, lighting, kitchen appliance, laundry, hvac, garage, exterior, and required interconnected smoke/co alarm circuits. install new 200-amp service equipment, meter socket, service riser and conductors, grounding and bonding system, whole-home surge protection, breakers, and panel labeling

    Complete electrical rewire of existing 1,600 sq ft single-family residence. scope includes replacement of existing branch-circuit wiring; installation of code-compliant receptacle, lighting, kitchen appliance, laundry, hvac, garage, exterior, and required interconnected smoke/co alarm circuits. install new 200-amp service equipment, meter socket, service riser and conductors, grounding and bonding system, whole-home surge protection, breakers, and panel labeling

    City of Dallas permitResidential Electrical Permit
    Record
    RES-ELC-26-004535
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  4. Nsfaa alteration: patio converted to garage and roof replacement on main structure per fire report

    Nsfaa alteration: patio converted to garage and roof replacement on main structure per fire report

    City of Dallas permitResidential Alteration Addition Permit
    Record
    RES-ALT-ADD-26-000861
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  5. Nsfaa remove existing built-in roof framing down to the top plates. replace with new roof trusses from builders first source and associated framing in accordance with approved plans and current city of dallas building codes. scope includes replacement of all roof structural members, installation of roof decking, and preparation for roofing installation. roof configuration to match existing footprint with 5x12 and 6x12 gables as specified in approved plans. work to be performed in accordance with city of dallas inspection requirements

    Nsfaa remove existing built-in roof framing down to the top plates. replace with new roof trusses from builders first source and associated framing in accordance with approved plans and current city of dallas building codes. scope includes replacement of all roof structural members, installation of roof decking, and preparation for roofing installation. roof configuration to match existing footprint with 5x12 and 6x12 gables as specified in approved plans. work to be performed in accordance with city of dallas inspection requirements

    City of Dallas permitResidential Alteration Addition Permit
    Record
    RES-ALT-ADD-26-000870
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  6. Remove existing built-in-place roof roof and ceiling joists, down to the top plate. replace with new roof trusses from builds first source and associated framing in accordance with approved plans and current city of dallas building codes. scope includes replacement of all roof structural members, installation of roof decking, and preparation for roofing installation. roof configuration to match existing footprint with 5x12 and 6x12 gables as specified in approved plans. work to be performed in accordance with city of dallas inspection requirements

    Remove existing built-in-place roof roof and ceiling joists, down to the top plate. replace with new roof trusses from builds first source and associated framing in accordance with approved plans and current city of dallas building codes. scope includes replacement of all roof structural members, installation of roof decking, and preparation for roofing installation. roof configuration to match existing footprint with 5x12 and 6x12 gables as specified in approved plans. work to be performed in accordance with city of dallas inspection requirements

    City of Dallas permitResidential Roofing Permit
    Record
    RES-ROOF-26-000719
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro

Sources: City of Dallas

Questions about 5307 Denton Dr

What is being built at 5307 Denton Dr?

Permits indicate renovations to an existing home, including roof replacement, converting a patio to a garage, and electrical, HVAC and plumbing work. The records do not describe a new building.

Is a new restaurant opening at 5307 Denton Dr?

The available permit descriptions document residential work, including roof, garage, electrical, HVAC and plumbing updates. They do not identify a restaurant opening.

When were permits filed for work at 5307 Denton Dr?

The earliest permits in this set were filed May 8, 2026, for roof replacement and roof framing work. The latest was filed November 6, 2026, for plumbing work.

Is the roof being replaced at 5307 Denton Dr?

Yes. Permits filed May 8, 2026, describe removing the existing roof framing and joists and installing new roof trusses and decking. The records include permits RES-ALT-ADD-26-000870 and RES-ROOF-26-000719.

Is the patio at 5307 Denton Dr being converted into a garage?

A May 12, 2026, residential alteration permit, RES-ALT-ADD-26-000861, describes converting a patio to a garage and replacing the roof on the main structure.

What electrical work is planned at 5307 Denton Dr?

A permit filed July 30, 2026, describes a complete electrical rewire of the existing 1,600-square-foot single-family home, including a new 200-amp service.

What plumbing and HVAC work is planned at 5307 Denton Dr?

Permits filed October 16 and November 6, 2026, cover residential HVAC work and plumbing alterations, including a shower upgrade and a new water heater.

Also being built nearby

All of 75235

More restaurants in 75235.

Get alerts for 5307 Denton Dr