groundranger
Recent · latest filing Aug 2025Residential

7108 Concord Ave

Dallas, TX 75235

Residential rooftop solar permits at 7108 Concord Ave

City of Dallas records indicate rooftop solar work at this single-family residence, including a 71-panel photovoltaic system permitted June 11, 2025. A separate solar permit dated August 13, 2025, describes a 31-module system, followed by an electrical permit on August 17 for work tied to an approved solar permit.

Summarized from City of Dallas records · updated Aug 17, 2025

Projects
3
3 filings
Latest filing
Aug 17, 2025
since Jun 11, 2025
Largest scope
—
Listed value
—

Permit & project history

3 projects
  1. Pulling electrical permit for approved solar panel permit

    Pulling electrical permit for approved solar panel permit

    City of Dallas permitResidential Electrical Permit
    Record
    RES-ELC-25-002299
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  2. Mcr this project involves the design and installation of a 31-module roof-mounted grid-tied solar photovoltaic (pv) system at the single-family residence of maria perez, located at 7108 concord ave, dallas, tx 75235. the system is designed to offset a significant portion of the homeowner’s electrical usage by utilizing renewable solar energy while remaining interconnected with the existing utility service provided by oncor electric delivery.system specifications:total dc system size: 12.55 kw dctotal ac system size: 9.3 kw acmodules: 31 x ja solar 405w high-efficiency photovoltaic modulesinverters: 31 x enphase iq8+ microinverters, one per modulemounting system: k2 systems crossrail 44-x on asphalt shingle roof, attached with k2 splicefoot xl hardwaremonitoring: integrated via enphase iq combiner 5c with iq gateway for real-time system performance trackinginstallation details:the modules are distributed across three roof sections:roof section 1: 9 modules, 36° tilt, 105° azimuthroof section 2: 8 modules, 35° tilt, 255° azimuthroof section 3: 14 modules (10 at 18°, 4 at 33°), 225° azimuthroof penetrations and attachments are engineered for structural integrity, complying with and standards.wiring is routed through rooftop junction boxes into conduit runs, terminating at the enphase combiner panel.electrical & interconnection:main service panel: 200a main breaker, 225a busbar, exterior-mountedservice voltage: 240v, single-phasepv interconnection: backfed breaker positioned opposite the main breaker per nec 705.12(b)ac disconnect: 50a non-fused, visible, lockable, labeled disconnect within 10 feet of utility meter, compliant with oncor requirementsesi id: 10443720008347938code compliance:designed and installed per the following codes:2020 national electrical code (nec)2021 international residential code ()2021 international building code ()2021 international fire code (ifc)local jurisdiction: city of dallassafety & quality assurance:all equipment is ul-listed and nec/ieee compliant, including ul 1741 and ieee 1547 certifications for interconnection.proper setbacks, access pathways, and roof vent clearances are observed per fire code.the pv system does not include battery storage and operates in a utility-interactive mode only

    Mcr this project involves the design and installation of a 31-module roof-mounted grid-tied solar photovoltaic (pv) system at the single-family residence of maria perez, located at 7108 concord ave, dallas, tx 75235. the system is designed to offset a significant portion of the homeowner’s electrical usage by utilizing renewable solar energy while remaining interconnected with the existing utility service provided by oncor electric delivery.system specifications:total dc system size: 12.55 kw dctotal ac system size: 9.3 kw acmodules: 31 x ja solar 405w high-efficiency photovoltaic modulesinverters: 31 x enphase iq8+ microinverters, one per modulemounting system: k2 systems crossrail 44-x on asphalt shingle roof, attached with k2 splicefoot xl hardwaremonitoring: integrated via enphase iq combiner 5c with iq gateway for real-time system performance trackinginstallation details:the modules are distributed across three roof sections:roof section 1: 9 modules, 36° tilt, 105° azimuthroof section 2: 8 modules, 35° tilt, 255° azimuthroof section 3: 14 modules (10 at 18°, 4 at 33°), 225° azimuthroof penetrations and attachments are engineered for structural integrity, complying with and standards.wiring is routed through rooftop junction boxes into conduit runs, terminating at the enphase combiner panel.electrical & interconnection:main service panel: 200a main breaker, 225a busbar, exterior-mountedservice voltage: 240v, single-phasepv interconnection: backfed breaker positioned opposite the main breaker per nec 705.12(b)ac disconnect: 50a non-fused, visible, lockable, labeled disconnect within 10 feet of utility meter, compliant with oncor requirementsesi id: 10443720008347938code compliance:designed and installed per the following codes:2020 national electrical code (nec)2021 international residential code ()2021 international building code ()2021 international fire code (ifc)local jurisdiction: city of dallassafety & quality assurance:all equipment is ul-listed and nec/ieee compliant, including ul 1741 and ieee 1547 certifications for interconnection.proper setbacks, access pathways, and roof vent clearances are observed per fire code.the pv system does not include battery storage and operates in a utility-interactive mode only

    City of Dallas permitResidential Solar/PV Permit
    Record
    RES-SOLAR-25-000196
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  3. Mcr installation of 28.755kw photovoltaic system with 71 panels, 71 inverters

    Mcr installation of 28.755kw photovoltaic system with 71 panels, 71 inverters

    City of Dallas permitResidential Solar/PV Permit
    Record
    RES-SOLAR-25-000097
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro

Sources: City of Dallas

Questions about 7108 Concord Ave

What is being built at 7108 Concord Ave?

City of Dallas permits indicate rooftop solar installations at the single-family residence. Records describe a 71-panel system and, in a separate permit, a 31-module system.

When were the solar permits filed for 7108 Concord Ave?

The City of Dallas records list solar permits dated June 11, 2025, and August 13, 2025. An electrical permit related to an approved solar permit was filed August 17, 2025.

How many solar panels are planned at 7108 Concord Ave?

The June 11, 2025, permit describes 71 panels. A separate permit dated August 13, 2025, describes 31 modules.

What size is the solar system at 7108 Concord Ave?

The June permit describes a 28.755-kilowatt photovoltaic system. The August permit describes a 12.55-kilowatt DC system.

Does the solar system at 7108 Concord Ave include battery storage?

The August 13, 2025, permit description says the 31-module system does not include battery storage and is designed to connect to the utility.

What is permit RES-ELC-25-002299 for?

The City of Dallas electrical permit, filed August 17, 2025, is described as pulling an electrical permit for an approved solar panel permit.

Also being built nearby

All of 75235

More warehouses & industrial in 75235, solar installs in 75235.

Get alerts for 7108 Concord Ave