Gas line repairs permitted at 8350 Denton Drive
A gas piping repair and testing project at 8350 Denton - Hanger A & B Dr was permitted on June 26, 2026. The work includes replacing damaged piping components, pressure-testing the gas line, and preparing it for inspection and gas service restoration.
Summarized from City of Dallas records · updated Jun 26, 2026
- Projects
- 1
- 1 filings
- Latest filing
- Jun 26, 2026
- since Jun 26, 2026
- Largest scope
- —
- Listed value
- —
Permit & project history
1 projectGas leak repairscope of work includes:* obtain required permit due to gas service being shut off by atmos energy* provide two technicians for repair and testing process* excavate around existing gas riser to access damaged piping components* cut beneath existing coupling and remove affected section of piping* install new coupling, flange, short section of pipe, gasket, and new bolts* press and secure all new gas piping connections* pressure test gas line with compressed air to verify system integrity and confirm no leaks are present* initial repair is expected to require one full day* second day will be required to test the building gas system and ensure readiness for city/utility inspection* additional day for one technician may be required to meet inspector and coordinate final approval once gas line passes testing* restore work area upon completion of repairs and testing* verify proper operation and readiness for gas service restoration after inspection approval
Gas leak repairscope of work includes:* obtain required permit due to gas service being shut off by atmos energy* provide two technicians for repair and testing process* excavate around existing gas riser to access damaged piping components* cut beneath existing coupling and remove affected section of piping* install new coupling, flange, short section of pipe, gasket, and new bolts* press and secure all new gas piping connections* pressure test gas line with compressed air to verify system integrity and confirm no leaks are present* initial repair is expected to require one full day* second day will be required to test the building gas system and ensure readiness for city/utility inspection* additional day for one technician may be required to meet inspector and coordinate final approval once gas line passes testing* restore work area upon completion of repairs and testing* verify proper operation and readiness for gas service restoration after inspection approval
City of Dallas permitCommercial Plumbing Permit
Sources: City of Dallas
Questions about 8350 Denton - Hanger A & B Dr
What is happening at 8350 Denton - Hanger A & B Dr?
A City of Dallas commercial plumbing permit covers repairs to a gas line and testing of the building’s gas system. The permit was issued June 26, 2026, under COM-PLM-26-002280.
Is a new building being built at 8350 Denton Drive?
The permit record describes gas line repairs, not new building construction. The work includes replacing damaged piping components and testing the line.
Why is gas line work happening at this address?
The permit scope says gas service had been shut off by Atmos Energy and that damaged piping components needed repair.
What repairs are planned at 8350 Denton Drive?
The work includes excavating around the existing gas riser, removing an affected section of pipe, and installing a new coupling, flange, pipe section, gasket, and bolts.
Will the gas line be inspected after repairs?
Yes. The permit scope calls for pressure testing the line and coordinating a city or utility inspection after it passes testing.
When was the gas repair permit filed?
The City of Dallas permit, COM-PLM-26-002280, is dated June 26, 2026.
Also being built nearby
All of 75235- 8350 Denton DrSep 30, 2025Replace 2 rtus · 35 m away
- 2734 Brookfield AveAug 21, 2025Emc electrical contractors and pittman power will be performing electrical troubleshooting on the main breaker to facility, due to recent tripping event · 160 m away
- 2607 W Amherst AveNov 13, 2025Gas relay from meter to home · 169 m away
- 2607 W Lovers LnMay 28, 2026Nsfaa repair outside siding and paintrepair inside sheetrock, texture it and paint.install new lights and fixturesopen the kitchen to the living room by taking out the dividing wall.replace all the windows with same size · 170 m away
- 2602 W Lovers LnFeb 10, 2026Replace roof · 179 m away
- 2518 W Amherst AveMay 15, 2025Install new hvac equipment with duct work · 236 m away
- 8558 Denton DrNov 16, 2026Electrical for addition · 241 m away
- 2523 W Lovers LnAug 18, 2026Gas test · 242 m away
- 2519 W Lovers LnJun 30, 20252519 w lovers lane - 8 foot tall wood fence · 246 m away
- 2529 Brookfield AveJan 6, 2021Gas test · 272 m away
- 2742 Burbank StOct 30, 2026Jackhammer a 4’x4’ area in cleaning bay to access cast iron pipe. riddell plumbing to make a spot repair on collapsed 2” cast iron pipe connecting to the 3” cast iron in concrete · 274 m away
- 2523 Brookfield AveJan 14, 2026Nsfaa siding and fence repair. this is a general repairs review. there should be no additions done with this permit. only minor structural repairs to the front of the house · 275 m away