10028 Royal Ln
Dallas, TX 75238
Permits cover foundation and structural repairs at 10028 Royal Ln
City of Dallas permits filed from March 26 through June 15, 2026, cover plumbing work, steel-pile foundation repairs and structural repairs at 10028 Royal Ln. The June 15 permit describes replacing a failed second-level landing beam, supporting and re-leveling roof trusses, and addressing related damage.
Summarized from City of Dallas records · updated Jun 15, 2026
- Projects
- 13
- 13 filings
- Latest filing
- Jun 15, 2026
- since Mar 26, 2026
- Largest scope
- —
- Listed value
- —
Permit & project history
13 projectsMcr scope of work is for the repair of the damage beam at building 26, phase 2o remove and replace existing 32 lf structural frame beam located at the second-level landing of building 16 ? provide temporary shoring and structural support as required to safely remove the existing failed beam? lift and re-level affected roof trusses that have dropped due to beam failure, restoring them to their original position prior to installation of the new beam ? install new structural beam per engineering specifications o address wood rot in mansard/parapet wall trusses caused by prior water intrusiono remove and replace 2 ea 4”x4” metal posts and base plateso replace missing bricks on both sides of landing (2nd floor)o obtain all required permits, schedule and coordinate all city inspections, and ensure proper permit close-out upon completiono clean and remove all debris generated by the scope of work
Mcr scope of work is for the repair of the damage beam at building 26, phase 2o remove and replace existing 32 lf structural frame beam located at the second-level landing of building 16 ? provide temporary shoring and structural support as required to safely remove the existing failed beam? lift and re-level affected roof trusses that have dropped due to beam failure, restoring them to their original position prior to installation of the new beam ? install new structural beam per engineering specifications o address wood rot in mansard/parapet wall trusses caused by prior water intrusiono remove and replace 2 ea 4”x4” metal posts and base plateso replace missing bricks on both sides of landing (2nd floor)o obtain all required permits, schedule and coordinate all city inspections, and ensure proper permit close-out upon completiono clean and remove all debris generated by the scope of work
City of Dallas permitCommercial Alteration Addition Permit
Sources: City of Dallas
Questions about 10028 Royal Ln
What is being built at 10028 Royal Ln?
The permits describe repairs rather than a new building: foundation work using steel piles and structural beam repairs. A commercial plumbing permit was also filed March 26, 2026.
Are there foundation repairs planned at 10028 Royal Ln?
Yes. Five City of Dallas commercial foundation repair permits filed April 13, 2026, describe installing steel piles to prevent further downward movement.
What structural work is planned at 10028 Royal Ln?
Permit COM-ALT-ADD-26-001191, filed June 15, 2026, describes replacing a failed beam at a second-level landing, supporting and re-leveling affected roof trusses, and repairing related damage.
When were permits filed for work at 10028 Royal Ln?
The records span March 26 to June 15, 2026. The plumbing permit was filed March 26, the foundation repair permits April 13, and the structural repair permit June 15.
Is a new business opening at 10028 Royal Ln?
The available permits do not identify a new business or tenant. They describe repair work, including foundation and structural repairs.
What does permit COM-ALT-ADD-26-001191 cover?
Filed June 15, 2026, the permit covers replacement of a failed structural beam at a second-level landing, temporary shoring, roof-truss re-leveling and other repairs described in the permit.
Also being built nearby
All of 75238- 9901 Royal LnFeb 19, 2026New split system installation · 87 m away
- 10075 Royal LnNov 20, 2025At building 3 - replace backflow device next to the water meter at the front flower bed · 141 m away
- 10725 Audelia RdOct 16, 2025Install 1,000 gal. grease trap--gas lines to kitchen · 181 m away
- 10729 Audelia RdNov 20, 2020Erect attached sign · 182 m away
- 10729 Audelia RdAug 14, 2025No work · 182 m away
- 10110 Royal LnOct 2, 2026Installation of one 6x5 type 2 vent hood & one 5x4 type 1 with duct work · 218 m away
- 11015 Ferndale RdJul 21, 20265 ton base downflow gas system · 218 m away
- 11009 Ferndale RdJan 19, 2026376 ft lineal feet of floor joist115 ft lineal feet of girder beam · 219 m away
- 11022 Ferndale RdJul 9, 2026Gas pressure test · 222 m away
- 9724 Highland View DrNov 8, 2024Installing 50 gal elec water heater · 240 m away
- 10945 Ferndale RdAug 18, 2025Nsfaa-detached pergola · 243 m away
- 10130 Royal LnOct 8, 2026Site lighting and shell work for starbucks · 248 m away