5159 Lauderdale Dr
Dallas, TX 75241
Gas line replacement and water heater circuit at 5159 Lauderdale Dr
Dallas permits indicate gas piping work for the stove and water heater at 5159 Lauderdale Dr, filed Oct. 6, 2026. A separate electrical permit to add a water heater circuit was filed Oct. 15, 2026.
Summarized from City of Dallas records · updated Oct 15, 2026
- Projects
- 2
- 2 filings
- Latest filing
- Oct 15, 2026
- since Oct 6, 2026
- Largest scope
- —
- Listed value
- —
Permit & project history
2 projectsTechnician will remove the existing 1-inch gas line connected to the meter and install a new 1-inch gas line routed underneath the home. the new line will transition to 3/4-inch piping and be routed up through the floor near the stove and water heater. the 3/4-inch line will be properly configured with 90-degree fittings and tee’d off, reducing to 1/2-inch piping to provide dedicated gas supply connections to both the stove and water heater. new 1/2-inch appliance supply lines will be installed for each fixture, along with two new gas shutoff valves—one at the stove and one at the water heater—and a new drip leg at the water heater. all piping and fittings will be properly assembled, supported, and secured, and the completed gas system will be pressure tested for leaks and verified for proper operation
Technician will remove the existing 1-inch gas line connected to the meter and install a new 1-inch gas line routed underneath the home. the new line will transition to 3/4-inch piping and be routed up through the floor near the stove and water heater. the 3/4-inch line will be properly configured with 90-degree fittings and tee’d off, reducing to 1/2-inch piping to provide dedicated gas supply connections to both the stove and water heater. new 1/2-inch appliance supply lines will be installed for each fixture, along with two new gas shutoff valves—one at the stove and one at the water heater—and a new drip leg at the water heater. all piping and fittings will be properly assembled, supported, and secured, and the completed gas system will be pressure tested for leaks and verified for proper operation
City of Dallas permitResidential Plumbing Permit
Sources: City of Dallas
Questions about 5159 Lauderdale Dr
What work is permitted at 5159 Lauderdale Dr?
Dallas permits cover replacement and rerouting of a gas line serving the stove and water heater, plus a new circuit for the water heater. The permits were filed Oct. 6 and Oct. 15, 2026.
Is a new home being built at 5159 Lauderdale Dr?
The records provided show residential plumbing and electrical permits, not a new-home construction permit. The work listed is for gas piping and a water heater circuit.
What is happening with the gas line at 5159 Lauderdale Dr?
A plumbing permit filed Oct. 6, 2026, covers removing the existing 1-inch gas line and installing new piping with separate connections for the stove and water heater. The scope also includes shutoff valves, a drip leg at the water heater, and pressure testing.
Is the water heater being replaced at 5159 Lauderdale Dr?
The permits do not state that the water heater itself is being replaced. They cover a new electrical circuit for the water heater and new gas piping to serve it.
When were permits filed for 5159 Lauderdale Dr?
The gas-line plumbing permit, RES-PLM-26-010654, was filed Oct. 6, 2026. The electrical permit for a water heater circuit, RES-ELC-26-006417, was filed Oct. 15, 2026.
Also being built nearby
All of 75241- 5138 Lauderdale DrJul 10, 2026Replace 2.5 ton complete gas system · 78 m away
- 5184 Lauderdale DrMay 5, 2025Gas test for meter release · 100 m away
- 5127 Cardiff StJan 29, 2026Nsfaa new sfd construction · 108 m away
- 5130 Lauderdale DrJul 16, 2026Fence already there, no work is being done · 108 m away
- 5134 Cardiff StAug 27, 2025Need a gas inspection to restore gas · 114 m away
- 5143 Watson DrMay 4, 20264 ton hvac system · 126 m away
- 5151 Watson DrDec 2, 2025This project consists of constructing a free-standing metal carport with overall dimensions of 12.5 ft by 41 ft. the structure will be installed on a reinforced 4-inch concrete slab with integrated footings at each post location. the carport will be built using metal posts, metal beams, and metal roof panels sloped for drainage. the carport will be located 5 ft from the side property line, approximately 2 ft from the existing residence, and fully behind the 22 ft front setback line as shown on the plans. no utilities, electrical, plumbing, or mechanical work are included in this scope · 129 m away
- 5122 Lauderdale DrJul 9, 2026Re-roof · 139 m away
- 5107 Cardiff StFeb 2, 2026Gas test for gas company to get gas turned on · 177 m away
- 5108 Cardiff StJun 12, 2026Replace overhead pipe and wire due to storm damage · 179 m away
- 5134 Southwick DrMay 29, 2026Replace 3 ton complete gas system · 229 m away
- 5130 Southwick DrOct 7, 2025Gas test · 231 m away