6227 Harmony Ln
Dallas, TX 75241
Plumbing upgrades and rooftop solar at 6227 Harmony Ln
Permits at this existing single-family home cover plumbing work and a rooftop solar installation. The solar permit was filed June 26, 2025, sewer replacement on June 15, 2026, and interior water-piping work on October 1, 2026.
Summarized from City of Dallas records · updated Oct 1, 2026
- Projects
- 3
- 3 filings
- Latest filing
- Oct 1, 2026
- since Jun 26, 2025
- Largest scope
- —
- Listed value
- —
Permit & project history
3 projectsInterior domestic water distribution in an existing single-family residence. existing water service has previously been brought into the residence under a prior plumbing/sewer permit. homeowner will distribute domestic cold and hot water piping through existing attic spaces, interior wall cavities, and a framed non-structural plumbing chase/soffit where attic space is not available. water service will be provided to one shower, two bathroom lavatories, two toilets, water heater, a kitchen sink, dishwasher, refrigerator, and laundry connections. no new exterior water service connection is proposed. existing sewer/drain/vent work is not being modified except where specifically identified on the submitted plans
Interior domestic water distribution in an existing single-family residence. existing water service has previously been brought into the residence under a prior plumbing/sewer permit. homeowner will distribute domestic cold and hot water piping through existing attic spaces, interior wall cavities, and a framed non-structural plumbing chase/soffit where attic space is not available. water service will be provided to one shower, two bathroom lavatories, two toilets, water heater, a kitchen sink, dishwasher, refrigerator, and laundry connections. no new exterior water service connection is proposed. existing sewer/drain/vent work is not being modified except where specifically identified on the submitted plans
City of Dallas permitResidential Plumbing PermitAccess the plumbing system beneath the home remove all existing cast-iron sewer pipe and beneath the structure install a complete new pvc sewer system, using approved materials and proper connection methods reconnect all existing fixture drains and branch line as necessary install necessary fittings, transitions, and clean out required for a complete sewer re-pipe ensure proper slope, alignment and support throughout the entire sewer system secure, all newly installed, piping and accordance with current plumbing standards, testing entire sewer system for proper flow and leak free performance remove all debris associated with the replaced sewer piping from the work area. they find proper operation of the newly installed sewer system up upon completion
Access the plumbing system beneath the home remove all existing cast-iron sewer pipe and beneath the structure install a complete new pvc sewer system, using approved materials and proper connection methods reconnect all existing fixture drains and branch line as necessary install necessary fittings, transitions, and clean out required for a complete sewer re-pipe ensure proper slope, alignment and support throughout the entire sewer system secure, all newly installed, piping and accordance with current plumbing standards, testing entire sewer system for proper flow and leak free performance remove all debris associated with the replaced sewer piping from the work area. they find proper operation of the newly installed sewer system up upon completion
City of Dallas permitResidential Plumbing Permit
Sources: City of Dallas
Questions about 6227 Harmony Ln
What is being built at 6227 Harmony Ln?
The permits describe work on an existing home: an 8.20-kW rooftop solar installation with one Tesla Powerwall, sewer-pipe replacement, and interior domestic water piping.
Is a new house being built at 6227 Harmony Ln?
The records describe work on an existing single-family residence, not construction of a new house.
When was the solar permit filed at 6227 Harmony Ln?
The residential solar permit, RES-SOLAR-25-000046, was filed June 26, 2025, for 8.20 kW of rooftop solar panels and one Tesla Powerwall.
What plumbing work is happening at 6227 Harmony Ln?
A June 15, 2026 permit, RES-PLM-26-006180, covers replacing the home's existing cast-iron sewer pipes with PVC. A separate permit filed October 1, 2026, covers interior hot- and cold-water piping.
What does the October 2026 permit at 6227 Harmony Ln cover?
Permit RES-PLM-26-010439 covers distributing domestic hot and cold water through the existing home to fixtures and appliances. It does not propose a new exterior water-service connection.
Also being built nearby
All of 75241- 6219 Harmony LnOct 1, 2026Nsfaa-exterior alteration roof · 13 m away
- 6224 Harmony LnOct 3, 2025Gas test due to housing sitting vacant for so long · 13 m away
- 6216 Harmony LnDec 17, 2025Putting gas gauge to turn gas back on · 20 m away
- 6211 Songwood DrJan 28, 2021Install roofing mountage solar panels · 72 m away
- 6239 Songwood DrJul 2, 2026Replacing 3 ton furance only · 106 m away
- 6204 Songwood DrJun 10, 20268ft wood fence (board on board) · 107 m away
- 6250 Songwood DrMar 10, 2026Gas test · 127 m away
- 6307 Harmony LnNov 9, 2026Residential re-roof asphalt shingles. planning on removing solar panels, shingles and re-shingling roof. do not plan on reinstalling solar panels per homeowner request · 129 m away
- 6227 Bowling Brook DrAug 13, 2026Gas inspection · 131 m away
- 6314 Harmony LnJun 23, 2025Replace weather head and riser conductors with new weather head and conductors · 141 m away
- 6323 Harmony LnApr 16, 2026Gas test · 155 m away
- 6119 Harmony LnAug 18, 2025Gas test · 173 m away
More warehouses & industrial in 75241, restaurants in 75241, solar installs in 75241.