12516 Audelia Rd
Dallas, TX 75243
Fire-damage repairs at Huntington Brook Apartments
A Dallas permit filed November 2, 2026, covers fire- and water-damage repairs at Building 10 of Huntington Brook Apartments, including work in units 1010, 1011 and 1012. The scope includes roof, interior, electrical, HVAC and plumbing repairs; the permit says there will be no change of use or added floor area or dwelling units.
Summarized from City of Dallas records · updated Nov 2, 2026
- Projects
- 3
- 3 filings
- Latest filing
- Nov 2, 2026
- since Mar 24, 2026
- Largest scope
- —
- Listed value
- —
Permit & project history
3 projectsMcr fire damage repair at huntington brook apartments, building 10 (r-2, type va, ). unit 1012 (fire origin, 2nd floor): replace fire-damaged roof trusses (engineered by truss manufacturer), roof decking, underlayment and asphalt shingles; new drywall throughout walls and ceilings; new interior doors and flooring; new electrical wiring, receptacles, switches, light fixtures, smoke detectors and 125a panel; new hvac condenser, air handler and ductwork; replace plumbing fixtures like-for-like; repair exterior fiber cement siding, soffit, fascia and gutters. unit 1011 (water/smoke damage): new drywall throughout, paint, new interior doors and flooring; replace outlets, switches and plumbing fixtures as needed; existing hvac and plumbing lines to remain. unit 1010 (smoke damage): attic insulation, drywall texture, flooring and paint repairs. attic: clean, seal and deodorize trusses; replace blown-in insulation. no change of use, no added floor area or dwelling units
Mcr fire damage repair at huntington brook apartments, building 10 (r-2, type va, ). unit 1012 (fire origin, 2nd floor): replace fire-damaged roof trusses (engineered by truss manufacturer), roof decking, underlayment and asphalt shingles; new drywall throughout walls and ceilings; new interior doors and flooring; new electrical wiring, receptacles, switches, light fixtures, smoke detectors and 125a panel; new hvac condenser, air handler and ductwork; replace plumbing fixtures like-for-like; repair exterior fiber cement siding, soffit, fascia and gutters. unit 1011 (water/smoke damage): new drywall throughout, paint, new interior doors and flooring; replace outlets, switches and plumbing fixtures as needed; existing hvac and plumbing lines to remain. unit 1010 (smoke damage): attic insulation, drywall texture, flooring and paint repairs. attic: clean, seal and deodorize trusses; replace blown-in insulation. no change of use, no added floor area or dwelling units
City of Dallas permitCommercial Alteration Addition Permit
Sources: City of Dallas
Questions about 12516 Audelia Rd
What is happening at 12516 Audelia Road in Dallas?
A November 2, 2026, City of Dallas permit covers repairs to Building 10 at Huntington Brook Apartments after fire, smoke and water damage. The work is repairs, not an expansion or change of use.
What is being repaired at Huntington Brook Apartments?
The permit covers repairs to the roof, drywall, doors, flooring, electrical systems, HVAC and plumbing in units 1010, 1011 and 1012, along with attic and exterior repairs. It was filed November 2, 2026, as permit COM-ALT-ADD-26-002670.
Is a new apartment building being built at 12516 Audelia Road?
The latest permit describes repairs to an existing apartment building, not new construction. It states there will be no added floor area or dwelling units.
Which apartments at Huntington Brook were affected by the damage?
The November 2, 2026, permit identifies unit 1012 as the fire-origin unit and describes water or smoke damage in units 1011 and 1010. The work is in Building 10.
What other permits were filed at 12516 Audelia Road in 2026?
A May 20, 2026, electrical permit, COM-ELC-26-002235, lists Buildings 3, 11 and 21. A March 24, 2026, plumbing permit, COM-PLM-26-001108, concerns a gas leak at the meter by Building 22.
Also being built nearby
All of 75243- 9788 Walnut St · Lee And Walnut Assoc LtdSep 16, 2026Clean/show · 50 m away
- 9780 Walnut StSep 4, 2026Repaired gas valve leak for furnace on the roof · 68 m away
- 9820 Walnut StMar 25, 2026Install new backflow devise · 109 m away
- 13030 Audelia RdApr 9, 2026Replace double check at front of property · 137 m away
- 12920 Audelia RdFeb 13, 2026Install 4 total pilings · 138 m away
- 9751 Walnut StFeb 9, 2026Came out today because eden is trying to get power turned on to her business suit that she recently acquired. oncor is requiring a city inspection before they will turn on power. i advised eden that we could pull the permit but would need to inspect the building for any potential violations that would cause the city inspection to fail. built estimate and looked over everything, found (2) open splices above the drop tile ceiling and a few other items. repaired those items and closed everything back up. we are now ready for the inspection. if the city requires additional work to be done, we will build additional estimates. no issues at close · 141 m away
- 12995 Audelia RdSep 8, 2026Install electrical service for a charter power supply cabinet per oncor · 161 m away
- 9801 Walnut StSep 1, 2026Replace 1- 2 ton electric heat pump hvac system in wall · 166 m away
- 12809 Audelia RdJul 1, 2026Repair damage to meter base and disconnect from vandalism · 170 m away
- 13015 Audelia RdSep 20, 2026Replace double check valve outside of building 6 · 186 m away
- 9850 Walnut StJun 9, 2025Qteam meeting 7.8.25 addition of 16k square feet to existing worship facility · 216 m away
- 9850 Walnut St, Dallas, TX 75243 · Special Event CenterOct 18, 2024Dallas chin baptist church — new construction — free standing new multipurpose addition with large open area, mezzanine and platform, with kitchen and restrooms · 216 m away