8804 Westfield Dr
Dallas, TX 75243
Home addition and HVAC replacement at 8804 Westfield Dr
City of Dallas permits record an addition to a single-family home at 8804 Westfield Dr, filed October 22, 2020. A separate HVAC replacement permit was filed July 11, 2025.
Summarized from City of Dallas records · updated Jul 11, 2025
- Projects
- 2
- 2 filings
- Latest filing
- Jul 11, 2025
- since Oct 22, 2020
- Largest scope
- —
- Listed value
- —
Permit & project history
2 projectsSources: City of Dallas
Questions about 8804 Westfield Dr
What is being built at 8804 Westfield Dr in Dallas?
City of Dallas records show an addition to a single-family home, permitted October 22, 2020, and an HVAC replacement permitted July 11, 2025.
When was the addition at 8804 Westfield Dr permitted?
The City of Dallas filing for an addition to a single-family home is dated October 22, 2020. The permit number is 2009221125.
Was HVAC work permitted at 8804 Westfield Dr?
Yes. A City of Dallas residential mechanical permit records an HVAC replacement filed July 11, 2025. The permit number is RES-MEC-25-001190.
Is 8804 Westfield Dr a new commercial development?
The permits provided are for an addition to a single-family home and an HVAC replacement. They do not record a new commercial development.
How many permits are recorded for 8804 Westfield Dr?
The City of Dallas records in this fact sheet show two filings: the home addition on October 22, 2020, and the HVAC replacement on July 11, 2025.
Also being built nearby
All of 75243- 9306 Clearwater DrApr 27, 2026Install 17 total pilings (16 exterior, 1 interior).install 1 angle iron · 116 m away
- 8839 Graywood DrJul 23, 2026Rebuild service, relocate panel, installed new ground rods, added one circuit to garage, installed gfci · 167 m away
- 9141 Amilie Vue LnAug 29, 2025Nsfaa-we are converting the sales office in our model home into a 2 car garage so we can sell it · 169 m away
- 8810 Hanford DrSep 23, 2025Installation of circuits for plugs and lights in living room · 170 m away
- 8710 Westfield DrSep 24, 2026Nsfaa **scope of work – 29.5' w x 17' l combo patio cover & concrete****patio cover:**construct a custom 29.5' w x 17' l (392 sq ft) cedar attached patio cover with a gable/low-pitch slant roof, decorative front fascia/trim, and approximately 12' finished top height. customer-provided dimensions are assumed correct; discrepancies requiring additional materials/work will be handled by change order.entire structure to be constructed with cedar, including (4) 6"x6" front/exposed posts (inset 1'), headers, rafters, fascia, trim, pony walls, and tongue-and-groove ceiling. front span supported by up to four posts. include roofline tie-in with approximately 192 sq ft of additional framing, plywood, shingles, and flashing.**structural tie-in:**install new independent concrete footings with commercial-grade simpson brackets for posts. structurally attach patio cover to existing house wall studs for load transfer and lateral stability. bottom of 4"x12" header boards approximately 8.5' high; final elevations depend on existing soffit, windows, ledgers, and roofline.**roofing:**cedar rafters, headers, risers, fascia, and visible trim. install plywood roof decking, full waterproofing/moisture barrier, and 30-year shingles matching the existing home. flash new roof into existing roof on two sides for a weather-tight connection. provide 12" roof overhang on front, left, and far-right sides. **no gutters.****ceiling:**full tongue-and-groove cedar ceiling throughout covered area. homeowner to select available ready seal stain/color. speaker company to complete required speaker wiring before tongue-and-groove ceiling installation.**electrical:**provide one dedicated circuit for outdoor lighting, fan, and outlets, with up to 150' of wiring to breaker panel through attic. includes (6) recessed can lights with switch, placement per homeowner preference; (1) ceiling fan box (homeowner supplies fan; 3 nails living installs); and (2) outdoor outlets.**plans, engineering & permits:**3 nails living to prepare plans/blueprints for city permit submission. homeowner approval of plans, design, and style required before submission. unforeseen structural requirements will be communicated and may result in a change order, including third-party engineering if required.**concrete – 392 sq ft regular brushed concrete:**prepare site by protecting adjacent landscaping/hardscape, removing existing surface/vegetation as needed, hauling debris, and excavating approximately 8–10" below finished grade. install and compact 4–6" crushed stone/base to 95% standard proctor. form slab, install welded wire mesh (6x6 w1.4/w1.4) or rebar as required, and pour approximately 4" of 3000–3500 psi air-entrained concrete. provide control/construction joints per industry standards. finish with broom texture and bullnose or square edges per homeowner preference. remove forms, clean site, and apply two coats of approved sealer after proper cure time (typically 7–28 days). includes excavation, base, reinforcement, concrete, forms, equipment, labor, finishing, jointing, sealing, cleanup, one mobilization, and minor debris disposal.**concrete assumptions:**392 sq ft area; 4" slab thickness unless otherwise specified; 3000–3500 psi concrete subject to local requirements; suitable site access for equipment/material delivery; work subject to weather conditions.**exclusions:**any new concrete/slab extension not specifically included. final stain/sealer color selected by homeowner. additional structural work or engineering required due to unforeseen site/home conditions may be subject to change order.**drainage:**install approximately 85 linear feet of french drain · 172 m away
- 9149 Amilie Vue LnJun 11, 2025New plumbing rough · 179 m away
- 8827 Graywood DrMar 18, 2026Remove the existing 200 amp outdoor surface-mounted electrical panel and replace it with a new 200 amp outdoor-rated panel. the new panel will be securely mounted in the same location, and all existing branch circuits will be properly labeled, terminated, and reconnected.the existing surge arrestor will be carefully removed and the powerworx will be wired into the new panel, ensuring proper connections and functionality · 188 m away
- 9125 Saddlecreek DrJan 12, 2025Residential new construction · 199 m away
- 9308 Greenville AveJun 25, 2026Installing new 50 gallon electric water heater in garage · 199 m away
- 9116 Clearwater DrAug 19, 20263 ton gas complete upflow hvac replacement · 210 m away
- 9032 Vista Creek DrJul 14, 2026Replacing 2, 200 amp panels, grounding and surge protection · 213 m away
- 9149 Saddlecreek DrDec 14, 2024Residential new sfr · 221 m away