9011 Arbor Park Dr
Dallas, TX 75243
Masonry side-yard wall and entry gate proposed in Dallas
A residential permit filed April 23, 2026, proposes a masonry wall and pedestrian gate at 9011 Arbor Park Dr in Dallas. The wall would run about 50 feet along the right side yard, with a height of 6 to 7 feet 6 inches; the gate would be 8 feet high and 4 feet wide.
Summarized from City of Dallas records · updated Apr 23, 2026
- Projects
- 1
- 1 filings
- Latest filing
- Apr 23, 2026
- since Apr 23, 2026
- Largest scope
- —
- Listed value
- —
Permit & project history
1 projectProposed work includes construction of a new masonry wall and pedestrian entry gate on the right side of the property, as viewed from the street facing the residence. all improvements will be located outside the front setback and behind the build line, along a portion of the right side yard. the wall will be approximately 50 linear feet in total length and constructed on a reinforced concrete foundation. it will be 16 inches wide and consist of masonry piers and brick surrounding reinforced concrete block. the wall height will be 6 feet for approximately 28 linear feet along the right side yard, then will increase while remaining level to 7 feet 6 inches where it connects to the neighboring existing 7-foot-6-inch brick side-yard wall, reflecting the site slope and grade change. a new pedestrian entry gate will also be installed at the front entry access point inside the covered patio and under preexisting second floor balcony. the gate door will be 96 inches high and 4 feet wide (two 2' panels opening inward), and it will be framed by two brick pillars, each 96 inches high and 16 inches wide.the design has been developed to comply with applicable fence regulations, including placement, and material standards. the wall will be vertical, with a top edge that is level and consistent with code requirements. the wall will run parallel and/or perpendicular to the building walls and lot lines and will not obstruct or screen significant architectural features of the main building or neighboring properties.?in accordance with masonry fence requirements:the color and dimensions of the masonry, as well as width, type, and elevation of mortar joints, will match the existing masonry and mortar joints of the primary residence as nearly as practicable.all exposed brick used in the wall and columns will be fired brick conforming to american society for testing and materials (astm) designation c-126-75a, type grade fbssw, as required by code.the portion of the residence enclosed by the privacy wall includes a sliding glass door and three exterior glass entry doors and several large glass windows that currently provide direct and unobstructed access to the house. the proposed wall and access gate are intended to provide reasonable security, privacy, and access control for occupants.the request is further supported by site-specific conditions, including consistent pedestrian traffic along the front of the property and documented neighborhood safety concerns, including recent violent fatal firearm crimes and ongoing petty crime. the proposed improvements are proportional in scale, compatible in material and design with the existing structure, and consistent with neighboring homes, including the connection to an existing neighboring masonry wall of 7’6” in height.all improvements are designed to meet applicable code requirements while minimizing visual impact and preserving the architectural character of the property and surrounding neighborhood
Proposed work includes construction of a new masonry wall and pedestrian entry gate on the right side of the property, as viewed from the street facing the residence. all improvements will be located outside the front setback and behind the build line, along a portion of the right side yard. the wall will be approximately 50 linear feet in total length and constructed on a reinforced concrete foundation. it will be 16 inches wide and consist of masonry piers and brick surrounding reinforced concrete block. the wall height will be 6 feet for approximately 28 linear feet along the right side yard, then will increase while remaining level to 7 feet 6 inches where it connects to the neighboring existing 7-foot-6-inch brick side-yard wall, reflecting the site slope and grade change. a new pedestrian entry gate will also be installed at the front entry access point inside the covered patio and under preexisting second floor balcony. the gate door will be 96 inches high and 4 feet wide (two 2' panels opening inward), and it will be framed by two brick pillars, each 96 inches high and 16 inches wide.the design has been developed to comply with applicable fence regulations, including placement, and material standards. the wall will be vertical, with a top edge that is level and consistent with code requirements. the wall will run parallel and/or perpendicular to the building walls and lot lines and will not obstruct or screen significant architectural features of the main building or neighboring properties.?in accordance with masonry fence requirements:the color and dimensions of the masonry, as well as width, type, and elevation of mortar joints, will match the existing masonry and mortar joints of the primary residence as nearly as practicable.all exposed brick used in the wall and columns will be fired brick conforming to american society for testing and materials (astm) designation c-126-75a, type grade fbssw, as required by code.the portion of the residence enclosed by the privacy wall includes a sliding glass door and three exterior glass entry doors and several large glass windows that currently provide direct and unobstructed access to the house. the proposed wall and access gate are intended to provide reasonable security, privacy, and access control for occupants.the request is further supported by site-specific conditions, including consistent pedestrian traffic along the front of the property and documented neighborhood safety concerns, including recent violent fatal firearm crimes and ongoing petty crime. the proposed improvements are proportional in scale, compatible in material and design with the existing structure, and consistent with neighboring homes, including the connection to an existing neighboring masonry wall of 7’6” in height.all improvements are designed to meet applicable code requirements while minimizing visual impact and preserving the architectural character of the property and surrounding neighborhood
City of Dallas permitResidential Accessory Structure Permit
Sources: City of Dallas
Questions about 9011 Arbor Park Dr
What is being built at 9011 Arbor Park Dr?
A City of Dallas residential permit proposes a masonry side-yard wall and a pedestrian entry gate. The filing date is April 23, 2026.
What is the permit number for the work at 9011 Arbor Park Dr?
The permit number is RES-ACC-26-000526. It was filed with the City of Dallas on April 23, 2026.
How long will the wall at 9011 Arbor Park Dr be?
The proposed masonry wall is approximately 50 linear feet long along part of the right side yard.
How tall will the new wall be at 9011 Arbor Park Dr?
The permit describes a wall that would be 6 feet high for about 28 feet, then rise to 7 feet 6 inches where it meets a neighboring existing wall.
Is a new gate planned for 9011 Arbor Park Dr?
Yes. The permit proposes a pedestrian entry gate inside the covered patio, measuring 8 feet high and 4 feet wide.
When was the wall and gate permit filed in Dallas?
The City of Dallas permit was filed April 23, 2026. The permit number is RES-ACC-26-000526.
Also being built nearby
All of 75243- 9019 Arbor Park DrFeb 4, 2026200 amp panel and meter base replacement · 8 m away
- 9104 Glen Springs DrApr 27, 2026Replacing sewer system under slab by tunneling · 97 m away
- 9107 Arbor Park DrAug 10, 2026Repair fresh water slab leak accessed by tunnel up to 10 · 99 m away
- 9110 Glen Springs DrJul 9, 2026Replace water line from main tap to house · 100 m away
- 9111 Arbor Park DrJul 21, 2026Replaced gas service line · 104 m away
- 9020 Glen Springs DrNov 7, 2025Remove and replace the existing horizontal gas system located in the attic, accessed via the hallway staircase. the new installation will include a 99% afue high-efficiency lennox furnace and matching high-efficiency condenser. the attic is spray-foamed, and all existing ductwork will be reused; no new ductwork will be installed. the outdoor unit is located on the left side of the home · 106 m away
- 9105 Glen Springs DrJan 20, 2026Whole home sewer repipe · 109 m away
- 9016 Glen Springs DrJun 8, 2026Remove and replace roof shingles · 110 m away
- 9031 Glen Springs CirApr 27, 2026Install 5 ton premium gas 80% horizontal system · 113 m away
- 9624 Robin Meadow DrAug 21, 202550 gal water heater replacement in closet in house · 157 m away
- 9604 Robin Meadow DrSep 17, 2025Roof solar- 39 module 15.99kw, line side tap · 192 m away
- 9631 Robin Meadow DrAug 19, 2025Demolition house · 197 m away