5072 Westgrove Dr
Dallas, TX 75248
Home HVAC system replacement and water-heater work
Permits indicate a home HVAC replacement at 5072 Westgrove Dr, including a 4-ton heat pump and an air handler relocated to the attic. The mechanical permit was filed September 23, 2025; later permits filed in November cover replacing the water heater and adding its electrical service.
Summarized from City of Dallas records · updated Nov 17, 2025
- Projects
- 6
- 6 filings
- Latest filing
- Nov 17, 2025
- since Sep 23, 2025
- Largest scope
- —
- Listed value
- —
Permit & project history
6 projectsProvide a dedicated 240 volt electrical service from the main panel with cutoff and whip for an electric water heater in closet
Provide a dedicated 240 volt electrical service from the main panel with cutoff and whip for an electric water heater in closet
City of Dallas permitResidential Electrical PermitRemove and haul off existing 40 gallon gas water heater in 2 nd floor closet.existing vent to be terminated in closet above water heater.furnish and install 1 – lochinvar 40 gallon 240v water heater in existing pan.furnish and install 1 – 1?2” trap primer routed to existing hub drain in closet.after installation is complete and tested, request city inspection. customer willneed to be home all day on the day of inspection to meet inspector on site.all work to be performed during normal business hours monday – friday8:00am – 5:00pm
Remove and haul off existing 40 gallon gas water heater in 2 nd floor closet.existing vent to be terminated in closet above water heater.furnish and install 1 – lochinvar 40 gallon 240v water heater in existing pan.furnish and install 1 – 1?2” trap primer routed to existing hub drain in closet.after installation is complete and tested, request city inspection. customer willneed to be home all day on the day of inspection to meet inspector on site.all work to be performed during normal business hours monday – friday8:00am – 5:00pm
City of Dallas permitResidential Plumbing PermitElectrical requirements – heat pump, air handler and heat kitheat pump electrical requirements for the daikin/amana alzt7ca4810a : voltage-phase-hz 208/230-1-60 minimum circuit ampacity 31.6 max. overcurrent protection 50 min / max volts 197/253 electrical conduit size 1/2" or 3/4" 1air handler electrical requirements for the daikin/amana amvt48cp14:voltage 208/240 minimum circuit ampacity 8.6/8.6 max. overcurrent device (amps) 15/15 minimum vac 197 maximum vac 253heat kit electrical requirements for the daikin/amana hksc15xb 15 kw heat kit nominal heat output: 15 kw (or 14.4 kw as indicated by some sources) voltage: 240 volts phase: 1-phase amperage: 62.5 amps maximum overcurrent protection: 60/25 ampssummary of breakers for the panel50 amp breaker for heat pump (may already be installed)25 amp breaker for air handler (may already be installed)60 amp breaker for heat kit (may already be installed)wire sizes specified and installed by electrical contractor 10/2 romex from main panel to air handler 4 gauge wire to main panel to heat kit at inside the air handler 8 gauge wire as necessary from main panel to heat pump on the roof. a cable (possibly adequate) exists from existing installation) electrical cut offs needed 2 new cuts off for the air handler and heat kit at the new location in the attic replace the electric cut off at heat pump on the roof (old federal pacific existing since original construction)
Electrical requirements – heat pump, air handler and heat kitheat pump electrical requirements for the daikin/amana alzt7ca4810a : voltage-phase-hz 208/230-1-60 minimum circuit ampacity 31.6 max. overcurrent protection 50 min / max volts 197/253 electrical conduit size 1/2" or 3/4" 1air handler electrical requirements for the daikin/amana amvt48cp14:voltage 208/240 minimum circuit ampacity 8.6/8.6 max. overcurrent device (amps) 15/15 minimum vac 197 maximum vac 253heat kit electrical requirements for the daikin/amana hksc15xb 15 kw heat kit nominal heat output: 15 kw (or 14.4 kw as indicated by some sources) voltage: 240 volts phase: 1-phase amperage: 62.5 amps maximum overcurrent protection: 60/25 ampssummary of breakers for the panel50 amp breaker for heat pump (may already be installed)25 amp breaker for air handler (may already be installed)60 amp breaker for heat kit (may already be installed)wire sizes specified and installed by electrical contractor 10/2 romex from main panel to air handler 4 gauge wire to main panel to heat kit at inside the air handler 8 gauge wire as necessary from main panel to heat pump on the roof. a cable (possibly adequate) exists from existing installation) electrical cut offs needed 2 new cuts off for the air handler and heat kit at the new location in the attic replace the electric cut off at heat pump on the roof (old federal pacific existing since original construction)
City of Dallas permitResidential Electrical PermitIn preparation for a new hvac installation, residential mechanical permit res-mec-25-002737 install a new condensate drain line from the location where a new air handler will be placed in the attic to the right side lavatory on master bedroom vanity. also install a new trap to receive water from the condensate line that will also service the lavatory
In preparation for a new hvac installation, residential mechanical permit res-mec-25-002737 install a new condensate drain line from the location where a new air handler will be placed in the attic to the right side lavatory on master bedroom vanity. also install a new trap to receive water from the condensate line that will also service the lavatory
City of Dallas permitResidential Plumbing PermitHvac system replacement with new plumbing and new air handler location in the attic. new electrical cables will be installed principally for the new location of the air handler in the atticthe new equipment is:daikin/amana alzt7ca 4810a heat pump ( 4 ton existing one is 3 ton )daikin/amana amvt48cp1300 air handler with heat kit (15 kw heat kit, existing one is 10 kw)the air handler will be placed in the attic. the existing one is in a furnace closet. (there is no furnace)new electric supply will be installed from the main breaker panel to the attic for the air handler and heat kit inside the air handler.the existing electric supply to the heat pump on the roof may be reused but the system is being upgraded from 3 ton to 4 ton with the appropriately sized electric cable to be determined by the electrician. a new cable to the heat pump on the roof may be required.circuit breakers will be installed to match the upgrade from 3 ton to 4 ton and the heat kit from 10 kw to 15 kwnew primary and secondary drain lines in ¾ inch pvc will be installed from the new installation of the of the air handler in the attic to an appropriate existing drain pipenew duct work will be installed with snap lock rigid pipe (cody pipe) according to design plans properly sealed and suspend, insulated with insulation wrap, r8 value
Hvac system replacement with new plumbing and new air handler location in the attic. new electrical cables will be installed principally for the new location of the air handler in the atticthe new equipment is:daikin/amana alzt7ca 4810a heat pump ( 4 ton existing one is 3 ton )daikin/amana amvt48cp1300 air handler with heat kit (15 kw heat kit, existing one is 10 kw)the air handler will be placed in the attic. the existing one is in a furnace closet. (there is no furnace)new electric supply will be installed from the main breaker panel to the attic for the air handler and heat kit inside the air handler.the existing electric supply to the heat pump on the roof may be reused but the system is being upgraded from 3 ton to 4 ton with the appropriately sized electric cable to be determined by the electrician. a new cable to the heat pump on the roof may be required.circuit breakers will be installed to match the upgrade from 3 ton to 4 ton and the heat kit from 10 kw to 15 kwnew primary and secondary drain lines in ¾ inch pvc will be installed from the new installation of the of the air handler in the attic to an appropriate existing drain pipenew duct work will be installed with snap lock rigid pipe (cody pipe) according to design plans properly sealed and suspend, insulated with insulation wrap, r8 value
City of Dallas permitResidential Mechanical Permit
Sources: City of Dallas
Questions about 5072 Westgrove Dr
What is being built at 5072 Westgrove Dr?
The records describe residential equipment upgrades, not a new building: an HVAC system replacement and water-heater work. The HVAC permit, RES-MEC-25-002737, was filed September 23, 2025.
Is a new HVAC system being installed at 5072 Westgrove Dr?
Yes. The September 23, 2025, mechanical permit describes replacing the existing system with a 4-ton heat pump and moving the air handler from a closet to the attic.
What HVAC work is planned at 5072 Westgrove Dr?
The permit describes a new heat pump, attic air handler, upgraded heat kit, new electrical connections, drain lines and ductwork. The related mechanical permit is RES-MEC-25-002737.
Is a water heater being replaced at 5072 Westgrove Dr?
A November 7, 2025, plumbing permit describes removing an existing 40-gallon gas water heater and installing a 40-gallon electric water heater. The permit number is RES-PLM-25-007146.
When were permits filed for work at 5072 Westgrove Dr?
The records span September 23 through November 17, 2025. They include permits for HVAC, plumbing and electrical work.
Also being built nearby
All of 75248- 5066 Westgrove DrMay 13, 20263-ton heat pump full system replacement · 3 m away
- 5088 Westgrove DrNov 17, 2025Hvac changeout · 8 m away
- 5056 Westgrove DrOct 21, 2026Sewer mainline replacement · 8 m away
- 5052 Westgrove DrOct 7, 2025Upstairs hvac changeout · 10 m away
- 5046 Westgrove DrMay 19, 2025Hvac changeout · 13 m away
- 5110 Westgrove DrJul 22, 20262.5-ton heat pump full system replacement · 19 m away
- 5116 Westgrove DrJan 26, 20212 complete hvac change out · 22 m away
- 5022 Westgrove DrSep 17, 20253 ton heat pump system replacement · 25 m away
- 5020 Westgrove DrSep 2, 2026Provide 30amp disconnect for small elevator controller · 26 m away
- 5010 Westgrove DrApr 17, 2026Replace gas water heater in garage · 31 m away
- 5144 Westgrove DrJan 5, 2021Install water heater · 36 m away
- 5148 Westgrove DrAug 11, 20253 ton heat pump system replacement · 38 m away