5072 Westgrove Dr

Dallas, TX 75248

Home HVAC system replacement and water-heater work

Permits indicate a home HVAC replacement at 5072 Westgrove Dr, including a 4-ton heat pump and an air handler relocated to the attic. The mechanical permit was filed September 23, 2025; later permits filed in November cover replacing the water heater and adding its electrical service.

Summarized from City of Dallas records · updated Nov 17, 2025

Projects
6
6 filings
Latest filing
Nov 17, 2025
since Sep 23, 2025
Largest scope
—
Listed value
—

Permit & project history

6 projects
  1. Provide a dedicated 240 volt electrical service from the main panel with cutoff and whip for an electric water heater in closet

    Provide a dedicated 240 volt electrical service from the main panel with cutoff and whip for an electric water heater in closet

    City of Dallas permitResidential Electrical Permit
    Record
    RES-ELC-25-004581
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  2. Remove and haul off existing 40 gallon gas water heater in 2 nd floor closet.existing vent to be terminated in closet above water heater.furnish and install 1 – lochinvar 40 gallon 240v water heater in existing pan.furnish and install 1 – 1?2” trap primer routed to existing hub drain in closet.after installation is complete and tested, request city inspection. customer willneed to be home all day on the day of inspection to meet inspector on site.all work to be performed during normal business hours monday – friday8:00am – 5:00pm

    Remove and haul off existing 40 gallon gas water heater in 2 nd floor closet.existing vent to be terminated in closet above water heater.furnish and install 1 – lochinvar 40 gallon 240v water heater in existing pan.furnish and install 1 – 1?2” trap primer routed to existing hub drain in closet.after installation is complete and tested, request city inspection. customer willneed to be home all day on the day of inspection to meet inspector on site.all work to be performed during normal business hours monday – friday8:00am – 5:00pm

    City of Dallas permitResidential Plumbing Permit
    Record
    RES-PLM-25-007146
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  3. Electrical requirements – heat pump, air handler and heat kitheat pump electrical requirements for the daikin/amana alzt7ca4810a : voltage-phase-hz 208/230-1-60 minimum circuit ampacity 31.6 max. overcurrent protection 50 min / max volts 197/253 electrical conduit size 1/2" or 3/4" 1air handler electrical requirements for the daikin/amana amvt48cp14:voltage 208/240 minimum circuit ampacity 8.6/8.6 max. overcurrent device (amps) 15/15 minimum vac 197 maximum vac 253heat kit electrical requirements for the daikin/amana hksc15xb 15 kw heat kit nominal heat output: 15 kw (or 14.4 kw as indicated by some sources) voltage: 240 volts phase: 1-phase amperage: 62.5 amps maximum overcurrent protection: 60/25 ampssummary of breakers for the panel50 amp breaker for heat pump (may already be installed)25 amp breaker for air handler (may already be installed)60 amp breaker for heat kit (may already be installed)wire sizes specified and installed by electrical contractor 10/2 romex from main panel to air handler 4 gauge wire to main panel to heat kit at inside the air handler 8 gauge wire as necessary from main panel to heat pump on the roof. a cable (possibly adequate) exists from existing installation) electrical cut offs needed 2 new cuts off for the air handler and heat kit at the new location in the attic replace the electric cut off at heat pump on the roof (old federal pacific existing since original construction)

    Electrical requirements – heat pump, air handler and heat kitheat pump electrical requirements for the daikin/amana alzt7ca4810a : voltage-phase-hz 208/230-1-60 minimum circuit ampacity 31.6 max. overcurrent protection 50 min / max volts 197/253 electrical conduit size 1/2" or 3/4" 1air handler electrical requirements for the daikin/amana amvt48cp14:voltage 208/240 minimum circuit ampacity 8.6/8.6 max. overcurrent device (amps) 15/15 minimum vac 197 maximum vac 253heat kit electrical requirements for the daikin/amana hksc15xb 15 kw heat kit nominal heat output: 15 kw (or 14.4 kw as indicated by some sources) voltage: 240 volts phase: 1-phase amperage: 62.5 amps maximum overcurrent protection: 60/25 ampssummary of breakers for the panel50 amp breaker for heat pump (may already be installed)25 amp breaker for air handler (may already be installed)60 amp breaker for heat kit (may already be installed)wire sizes specified and installed by electrical contractor 10/2 romex from main panel to air handler 4 gauge wire to main panel to heat kit at inside the air handler 8 gauge wire as necessary from main panel to heat pump on the roof. a cable (possibly adequate) exists from existing installation) electrical cut offs needed 2 new cuts off for the air handler and heat kit at the new location in the attic replace the electric cut off at heat pump on the roof (old federal pacific existing since original construction)

    City of Dallas permitResidential Electrical Permit
    Record
    RES-ELC-25-003437
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  4. In preparation for a new hvac installation, residential mechanical permit res-mec-25-002737 install a new condensate drain line from the location where a new air handler will be placed in the attic to the right side lavatory on master bedroom vanity. also install a new trap to receive water from the condensate line that will also service the lavatory

    In preparation for a new hvac installation, residential mechanical permit res-mec-25-002737 install a new condensate drain line from the location where a new air handler will be placed in the attic to the right side lavatory on master bedroom vanity. also install a new trap to receive water from the condensate line that will also service the lavatory

    City of Dallas permitResidential Plumbing Permit
    Record
    RES-PLM-25-005419
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  5. Hvac system replacement with new plumbing and new air handler location in the attic. new electrical cables will be installed principally for the new location of the air handler in the atticthe new equipment is:daikin/amana alzt7ca 4810a heat pump ( 4 ton existing one is 3 ton )daikin/amana amvt48cp1300 air handler with heat kit (15 kw heat kit, existing one is 10 kw)the air handler will be placed in the attic. the existing one is in a furnace closet. (there is no furnace)new electric supply will be installed from the main breaker panel to the attic for the air handler and heat kit inside the air handler.the existing electric supply to the heat pump on the roof may be reused but the system is being upgraded from 3 ton to 4 ton with the appropriately sized electric cable to be determined by the electrician. a new cable to the heat pump on the roof may be required.circuit breakers will be installed to match the upgrade from 3 ton to 4 ton and the heat kit from 10 kw to 15 kwnew primary and secondary drain lines in ¾ inch pvc will be installed from the new installation of the of the air handler in the attic to an appropriate existing drain pipenew duct work will be installed with snap lock rigid pipe (cody pipe) according to design plans properly sealed and suspend, insulated with insulation wrap, r8 value

    Hvac system replacement with new plumbing and new air handler location in the attic. new electrical cables will be installed principally for the new location of the air handler in the atticthe new equipment is:daikin/amana alzt7ca 4810a heat pump ( 4 ton existing one is 3 ton )daikin/amana amvt48cp1300 air handler with heat kit (15 kw heat kit, existing one is 10 kw)the air handler will be placed in the attic. the existing one is in a furnace closet. (there is no furnace)new electric supply will be installed from the main breaker panel to the attic for the air handler and heat kit inside the air handler.the existing electric supply to the heat pump on the roof may be reused but the system is being upgraded from 3 ton to 4 ton with the appropriately sized electric cable to be determined by the electrician. a new cable to the heat pump on the roof may be required.circuit breakers will be installed to match the upgrade from 3 ton to 4 ton and the heat kit from 10 kw to 15 kwnew primary and secondary drain lines in ¾ inch pvc will be installed from the new installation of the of the air handler in the attic to an appropriate existing drain pipenew duct work will be installed with snap lock rigid pipe (cody pipe) according to design plans properly sealed and suspend, insulated with insulation wrap, r8 value

    City of Dallas permitResidential Mechanical Permit
    Record
    RES-MEC-25-002737
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  6. Interior removal of wall

    Interior removal of wall

    City of Dallas permitBuilding (BU) Multi Family Renovation$5
    Record
    1908191036
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro

Sources: City of Dallas

Questions about 5072 Westgrove Dr

What is being built at 5072 Westgrove Dr?

The records describe residential equipment upgrades, not a new building: an HVAC system replacement and water-heater work. The HVAC permit, RES-MEC-25-002737, was filed September 23, 2025.

Is a new HVAC system being installed at 5072 Westgrove Dr?

Yes. The September 23, 2025, mechanical permit describes replacing the existing system with a 4-ton heat pump and moving the air handler from a closet to the attic.

What HVAC work is planned at 5072 Westgrove Dr?

The permit describes a new heat pump, attic air handler, upgraded heat kit, new electrical connections, drain lines and ductwork. The related mechanical permit is RES-MEC-25-002737.

Is a water heater being replaced at 5072 Westgrove Dr?

A November 7, 2025, plumbing permit describes removing an existing 40-gallon gas water heater and installing a 40-gallon electric water heater. The permit number is RES-PLM-25-007146.

When were permits filed for work at 5072 Westgrove Dr?

The records span September 23 through November 17, 2025. They include permits for HVAC, plumbing and electrical work.