Fire restoration and repairs in eight units at 4055 Frankford Rd
Dallas permits indicate fire restoration to the original condition in eight units of Building 4 at 4055 Frankford Rd, with no structural changes. The alteration permit was filed September 10, 2026, followed by mechanical, electrical and plumbing permits through September 25, 2026.
Summarized from City of Dallas records · updated Sep 25, 2026
- Projects
- 5
- 5 filings
- Latest filing
- Sep 25, 2026
- since Dec 15, 2025
- Largest scope
- —
- Listed value
- —
Permit & project history
5 projectsMove kitchen lines for all 8 unit to other wall replace all tubs and shower valve stub all water and drain out as needed also replace all washer boxes
Move kitchen lines for all 8 unit to other wall replace all tubs and shower valve stub all water and drain out as needed also replace all washer boxes
City of Dallas permitCommercial Plumbing PermitCom-alt-add-26-002053scope of work: building #4411, 412, 413, 414, 421, 422, 423, 424install 1.5-ton system complete as follows1.5 ton furdown style airhandlers4 - supply dropsreturn b/rvent only dryer / bath exhaustprogrammable t statinstall line set with plenum rated low voltage, uv rated armorflexcode upgradeinstall 1.5-ton 454b heat pumps
Com-alt-add-26-002053scope of work: building #4411, 412, 413, 414, 421, 422, 423, 424install 1.5-ton system complete as follows1.5 ton furdown style airhandlers4 - supply dropsreturn b/rvent only dryer / bath exhaustprogrammable t statinstall line set with plenum rated low voltage, uv rated armorflexcode upgradeinstall 1.5-ton 454b heat pumps
City of Dallas permitCommercial Mechanical PermitPrimary permit: com-alt-add-26-002053 scope of work: complete inside rewire as followsmove / install 125 amp main breaker paneldedicated kitchen circuits220v range, airhandler, heat pumpcode complaint breakers in panels
Primary permit: com-alt-add-26-002053 scope of work: complete inside rewire as followsmove / install 125 amp main breaker paneldedicated kitchen circuits220v range, airhandler, heat pumpcode complaint breakers in panels
City of Dallas permitCommercial Electrical PermitMcr fire restoration back to original with no structural changes to building 4 units 411, 412, 413, 414, 421, 422, 423 and 424
Mcr fire restoration back to original with no structural changes to building 4 units 411, 412, 413, 414, 421, 422, 423 and 424
City of Dallas permitCommercial Alteration Addition PermitBuilding 4. oncor has power off to entire building. performed electrical safety check. confirmed that half of the building can safely have power restored. need temp release sent to oncor
Building 4. oncor has power off to entire building. performed electrical safety check. confirmed that half of the building can safely have power restored. need temp release sent to oncor
City of Dallas permitCommercial Electrical Permit
Sources: City of Dallas
Questions about 4055 Frankford Rd
What is being done at 4055 Frankford Rd in Dallas?
Permits describe fire restoration to the original condition in eight units of Building 4, with no structural changes. Later permits cover interior electrical, mechanical and plumbing work.
How many units are included in the work at 4055 Frankford Rd?
The September 10, 2026, alteration permit lists eight units: 411–414 and 421–424.
When were permits filed for work at 4055 Frankford Rd?
The records span December 15, 2025, through September 25, 2026. The fire-restoration alteration permit, COM-ALT-ADD-26-002053, was filed September 10, 2026.
What electrical work is permitted at 4055 Frankford Rd?
Permit COM-ELC-26-004781, filed September 23, 2026, describes an interior rewire, a 125-amp main breaker panel, dedicated kitchen circuits and other electrical updates.
What plumbing repairs are planned at 4055 Frankford Rd?
Permit COM-PLM-26-003807, filed September 25, 2026, describes moving kitchen lines, replacing tubs and shower valves, and replacing washer boxes in all eight units.
What mechanical work is permitted at 4055 Frankford Rd?
Permit COM-MEC-26-002487, filed September 23, 2026, describes installing 1.5-ton heat pump systems in units 412–414 and 421–424.
Also being built nearby
All of 75287- 4050 Frankford RdJul 30, 2026Swap main panel to 150-200 amp ch series copper breaker panel. lifetime warranty. fully labeled. full home surge protector, required by code. first responder disconnect. required by code.re pull feeders from meter to panel. grounding updated to city code · 83 m away
- 4003 Joshua LnApr 28, 2026Replace main panel and grounding · 126 m away
- 18167 Whispering Gables LnJan 19, 2026Replace 3 ton complete · 145 m away
- 4112 Country Brook DrSep 16, 202621 piers (see engineering report) · 151 m away
- 4015 Joshua LnNov 6, 2025Waterline replacement in yard · 153 m away
- 4115 Hollow Oak DrJul 9, 2025Remove existing roofing system and install iko cambridge 30 (weatherwood) shingles · 160 m away
- 4135 Hollow Oak DrJul 28, 2026Sewer spot repair in the yard · 177 m away
- 4108 Firebrick LnJul 8, 2026Replaced water line in yard · 187 m away
- 4039 Joshua LnJul 23, 2025Replacing fixtures throughout the home. moving switches in laundry, master bath due to removal of doors · 197 m away
- 18107 Whispering Gables LnNov 7, 2025Replace outdoor federal pacific panel with a new square d 200 amp main breaker outdoor panel · 206 m away
- 18091 Whispering Gables LnMay 16, 202550 gallon electric water heater in gargae · 233 m away
- 18110 MidwayFeb 20, 2026Addition of existing restaurant adding sinks and floor drains for prep area · 240 m away
More restaurants in 75287.