Home plumbing and HVAC replacement permits in Austin

City of Austin permits indicate plumbing and HVAC replacement work at the existing home, rather than a new building. The HVAC permit was filed May 6, 2026, and the plumbing permit was filed May 21, 2026; both are marked final.

Summarized from City of Austin records · updated May 21, 2026

Projects
3
3 filings
Latest filing
May 21, 2026
since Dec 10, 2024
Largest scope
—
Listed value
—

Where this project stands

Finaled

Trenched out side and tied onto existing main 1 1/4 pvc line in yard. trenched across to front of garage on side of home and drive way. ran new 1 pex water line into garage into floor case between second floor. ran all new pex water lines to every single fixture in home. for second floor of home ran water lines up chase in wall to second story attic dropped water lines from attic. at each toilet and lavatory since we installed new quarter turn emergency shut off valves new stainless water supply lines and chrome trim rings. installed new washer machine box and ice maker box. also installed two lines for out door spigots and installed new hose bibs. and new 3/4 stainless water supply lines with shut off valve on water heater. all new water lines were strapped and secured. after all work was completed performed pressure test on new system and insured pressure test held and no leaks were present at the time of completion. 10408 charette cove austin tx 78759

  1. AppliedMay 15, 2026
  2. IssuedMay 21, 2026
  3. WorkMay '26 – Jun '26
  4. Final inspectionJun 4, 2026

Passed final inspection Jun 4, 2026.

1 contact on this project · 1 phone number

Permit & project history

3 projects
  1. Trenched out side and tied onto existing main 1 1/4 pvc line in yard. trenched across to front of garage on side of home and drive way. ran new 1 pex water line into garage into floor case between second floor. ran all new pex water lines to every single fixture in home. for second floor of home ran water lines up chase in wall to second story attic dropped water lines from attic. at each toilet and lavatory since we installed new quarter turn emergency shut off valves new stainless water supply lines and chrome trim rings. installed new washer machine box and ice maker box. also installed two lines for out door spigots and installed new hose bibs. and new 3/4 stainless water supply lines with shut off valve on water heater. all new water lines were strapped and secured. after all work was completed performed pressure test on new system and insured pressure test held and no leaks were present at the time of completion. 10408 charette cove austin tx 78759

    Trenched out side and tied onto existing main 1 1/4 pvc line in yard. trenched across to front of garage on side of home and drive way. ran new 1 pex water line into garage into floor case between second floor. ran all new pex water lines to every single fixture in home. for second floor of home ran water lines up chase in wall to second story attic dropped water lines from attic. at each toilet and lavatory since we installed new quarter turn emergency shut off valves new stainless water supply lines and chrome trim rings. installed new washer machine box and ice maker box. also installed two lines for out door spigots and installed new hose bibs. and new 3/4 stainless water supply lines with shut off valve on water heater. all new water lines were strapped and secured. after all work was completed performed pressure test on new system and insured pressure test held and no leaks were present at the time of completion. 10408 charette cove austin tx 78759

    City of Austin permitPlumbing PermitFinal
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  2. Replacement of complete existing central heat and air system with or without duct work

    Replacement of complete existing central heat and air system with or without duct work

    City of Austin permitMechanical PermitFinal
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  3. Panelmeter base and grounding

    Panelmeter base and grounding

    City of Austin permitElectrical PermitExpired
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro

Sources: City of Austin

Questions about 10408 Charette Cv

What is being built at 10408 Charette Cv?

The permits indicate replacement work at an existing home, including new water lines and a replacement central heat and air system. They do not describe a new building.

Is a new home being built at 10408 Charette Cv?

The records provided do not indicate new home construction. They list plumbing and HVAC work at the existing home.

What plumbing work was permitted at 10408 Charette Cv?

Permit 2026-061579 PP, filed May 21, 2026, describes new water lines to the home’s fixtures, along with related plumbing connections. The permit is marked final.

Was the HVAC system replaced at 10408 Charette Cv?

A City of Austin mechanical permit filed May 6, 2026, covers replacement of the existing central heat and air system, with or without duct work. Permit 2026-054301 MP is marked final.

What is permit 2024-158068 EP for at 10408 Charette Cv?

The electrical permit, filed December 10, 2024, describes work on the panel meter base and grounding. Its status is expired.

When were the permits filed for 10408 Charette Cv?

The records list filings on December 10, 2024, May 6, 2026, and May 21, 2026. The 2024 electrical permit is expired; the 2026 mechanical and plumbing permits are marked final.