4155 Buena Vista St
Dallas, TX 75204
Office space at 4155 Buena Vista is becoming a restaurant
Existing office space at 4155 Buena Vista St is being renovated into a restaurant for Clark's Oyster Bar. A City of Dallas alteration permit was filed August 4, 2026, followed by plumbing and electrical permits on September 21.
Summarized from City of Dallas records · updated Sep 21, 2026
- Projects
- 3
- 3 filings
- Latest filing
- Sep 21, 2026
- since Aug 4, 2026
- Largest scope
- —
- Listed value
- —
Permit & project history
3 projectsQualifications 1. install 2" l press hard copper water service, 4" sanitary sewer & gt-2000 grease trap with sample well installed per plans 2. install pex water supply overhead per plans with split-seam insulation and air hammer arrestors per city code 3. install pex hot & cold supply overhead to all fixtures per plan with ceiling hangers at 5' per code 4. provide and install (9) 3" floor sinks, (5) 3" floor drains, & (1) 4"x7' trench drain with trap seals in fixtures per city code 5. install gas service from meter to gas appliances per plan, final appliance connection to gas stop provided by installer 6. gc will provide all rooftop vent and gas penetrations as needed, gc to install rooftop flashings and seal penetrations 7. install tankless water heaters on wall with dual horizontal vent piping through wall, gc to patch wall as needed 8. install pvc drain & pex water connections at all sinks & toilets per plan, commercial equipment & sink install by provider 9. core cement deck as needed for drain and water penetrations. gc to provide metal pan cutting below cores as needed 10. bid includes single roof drain and overflow drain with separate discharge down from roof to terminate 6" above grade 11. bid includes 3/4" hose bib and 2" pvc capped drain stub out at aquarium location, final connections provided by others 12. bid inlcudes 1 total watts hy-725 3/4" exterior frostproof hydrant with locking box, gc to provide frame for mounting 13. install 2" rpz with air gap & strainer on water main in riser closet. fire system water main above & below grade not inlcuded 14. install 1 1/2" pvc pump discharge line from elevator closet to water heater floor sink, pump & connection by others 15. install fire suppression anzel valve on gas supply, valve provided by others. safety button system installed by others 16. install aav on island sink locations per city code. loop vent systems are not included at island fixture locations 17. bid includes fixture trim per schedule below with pex crimp water stops and tubular drain connections per code 18. any additional plumbing not included in bid and requested by gc is billed as t&m on separate change order
Qualifications 1. install 2" l press hard copper water service, 4" sanitary sewer & gt-2000 grease trap with sample well installed per plans 2. install pex water supply overhead per plans with split-seam insulation and air hammer arrestors per city code 3. install pex hot & cold supply overhead to all fixtures per plan with ceiling hangers at 5' per code 4. provide and install (9) 3" floor sinks, (5) 3" floor drains, & (1) 4"x7' trench drain with trap seals in fixtures per city code 5. install gas service from meter to gas appliances per plan, final appliance connection to gas stop provided by installer 6. gc will provide all rooftop vent and gas penetrations as needed, gc to install rooftop flashings and seal penetrations 7. install tankless water heaters on wall with dual horizontal vent piping through wall, gc to patch wall as needed 8. install pvc drain & pex water connections at all sinks & toilets per plan, commercial equipment & sink install by provider 9. core cement deck as needed for drain and water penetrations. gc to provide metal pan cutting below cores as needed 10. bid includes single roof drain and overflow drain with separate discharge down from roof to terminate 6" above grade 11. bid includes 3/4" hose bib and 2" pvc capped drain stub out at aquarium location, final connections provided by others 12. bid inlcudes 1 total watts hy-725 3/4" exterior frostproof hydrant with locking box, gc to provide frame for mounting 13. install 2" rpz with air gap & strainer on water main in riser closet. fire system water main above & below grade not inlcuded 14. install 1 1/2" pvc pump discharge line from elevator closet to water heater floor sink, pump & connection by others 15. install fire suppression anzel valve on gas supply, valve provided by others. safety button system installed by others 16. install aav on island sink locations per city code. loop vent systems are not included at island fixture locations 17. bid includes fixture trim per schedule below with pex crimp water stops and tubular drain connections per code 18. any additional plumbing not included in bid and requested by gc is billed as t&m on separate change order
City of Dallas permitCommercial Plumbing PermitRenovation alteration of existing office space into new restaurant for clarks oyster bar within the existing building footprint
Renovation alteration of existing office space into new restaurant for clarks oyster bar within the existing building footprint
City of Dallas permitCommercial Alteration Addition Permit
Sources: City of Dallas
Questions about 4155 Buena Vista St
What is being built at 4155 Buena Vista St in Dallas?
A City of Dallas permit describes a renovation converting existing office space into a restaurant for Clark's Oyster Bar. The work is within the existing building footprint.
When was the restaurant project at 4155 Buena Vista permitted?
The commercial alteration permit, COM-ALT-ADD-26-001116, was filed August 4, 2026. Plumbing and electrical permits were filed September 21, 2026.
Is Clark's Oyster Bar opening at 4155 Buena Vista?
The August 4, 2026, permit describes renovations for a new restaurant for Clark's Oyster Bar. The records do not give an opening date.
What work is planned at 4155 Buena Vista?
The September 21 plumbing permit lists water and sewer service, drains, floor sinks, and connections for fixtures and appliances. An electrical installation permit was also filed that day.
What's going in near James Perse on N Fitzhugh Avenue?
A restaurant for Clark's Oyster Bar is planned in existing office space at 4155 Buena Vista St, about 104 meters from James Perse - Dallas. The alteration permit was filed August 4, 2026.
Is the restaurant at 4155 Buena Vista a new building?
No new building is described in the permit. It calls for renovating existing office space into restaurant space within the existing building footprint.
Also being built nearby
All of 75204- 4155 Buena Vista Street · Bvjv III 4155 LLCJul 1, 2026Clark's dallas — renovation/alteration — 3,300 sq ft renovation of an existing office building turning into restaurant space
- 4152 Buena Vista StOct 7, 2026Abatement and demolition of structure on site and associated parking and paving · 13 m away
- 4144 Buena Vista StOct 7, 2026Abatement and demolition of structure on sight. from jobsite, take right on fitzhugh and go east. take right on 75 and continue south and merge onto 45. continues south until you arrive at landfill, republic landfill ecd 5703 n 45 ennis, texas 75119 · 18 m away
- 4143 Buena Vista StAug 24, 2025Gas test · 21 m away
- 4139 Buena Vista StJun 15, 2026Replace hvac systems, and ductwork · 28 m away
- 4132 Buena Vista StSep 18, 2020Install water heater · 35 m away
- 4129 Buena Vista StJul 8, 2025Under slab sewer replacement and liner · 46 m away
- 4127 Buena Vista StDec 22, 2025Spot repair and replace cleanouts · 50 m away
- 3352 Miro PlMay 21, 2026Replace a 50 gallon gas water heater with a tankless · 59 m away
- 3344 Miro PlSep 18, 2025Replace 2 ton downstairs completecondenser on roof · 62 m away
- 3324 Miro PlJul 29, 2025Foundation repair-install 5 pilings · 74 m away
- 3328 Miro PlJul 29, 2025Foundation repair-install 10 pilings · 74 m away
More new homes in 75204, offices in 75204, restaurants in 75204.