4155 Buena Vista St

Dallas, TX 75204

Office space at 4155 Buena Vista is becoming a restaurant

Existing office space at 4155 Buena Vista St is being renovated into a restaurant for Clark's Oyster Bar. A City of Dallas alteration permit was filed August 4, 2026, followed by plumbing and electrical permits on September 21.

Summarized from City of Dallas records · updated Sep 21, 2026

Projects
3
3 filings
Latest filing
Sep 21, 2026
since Aug 4, 2026
Largest scope
—
Listed value
—

Permit & project history

3 projects
  1. Electrical installation

    Electrical installation

    City of Dallas permitCommercial Electrical Permit
    Record
    COM-ELC-26-004719
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  2. Qualifications 1. install 2" l press hard copper water service, 4" sanitary sewer & gt-2000 grease trap with sample well installed per plans 2. install pex water supply overhead per plans with split-seam insulation and air hammer arrestors per city code 3. install pex hot & cold supply overhead to all fixtures per plan with ceiling hangers at 5' per code 4. provide and install (9) 3" floor sinks, (5) 3" floor drains, & (1) 4"x7' trench drain with trap seals in fixtures per city code 5. install gas service from meter to gas appliances per plan, final appliance connection to gas stop provided by installer 6. gc will provide all rooftop vent and gas penetrations as needed, gc to install rooftop flashings and seal penetrations 7. install tankless water heaters on wall with dual horizontal vent piping through wall, gc to patch wall as needed 8. install pvc drain & pex water connections at all sinks & toilets per plan, commercial equipment & sink install by provider 9. core cement deck as needed for drain and water penetrations. gc to provide metal pan cutting below cores as needed 10. bid includes single roof drain and overflow drain with separate discharge down from roof to terminate 6" above grade 11. bid includes 3/4" hose bib and 2" pvc capped drain stub out at aquarium location, final connections provided by others 12. bid inlcudes 1 total watts hy-725 3/4" exterior frostproof hydrant with locking box, gc to provide frame for mounting 13. install 2" rpz with air gap & strainer on water main in riser closet. fire system water main above & below grade not inlcuded 14. install 1 1/2" pvc pump discharge line from elevator closet to water heater floor sink, pump & connection by others 15. install fire suppression anzel valve on gas supply, valve provided by others. safety button system installed by others 16. install aav on island sink locations per city code. loop vent systems are not included at island fixture locations 17. bid includes fixture trim per schedule below with pex crimp water stops and tubular drain connections per code 18. any additional plumbing not included in bid and requested by gc is billed as t&m on separate change order

    Qualifications 1. install 2" l press hard copper water service, 4" sanitary sewer & gt-2000 grease trap with sample well installed per plans 2. install pex water supply overhead per plans with split-seam insulation and air hammer arrestors per city code 3. install pex hot & cold supply overhead to all fixtures per plan with ceiling hangers at 5' per code 4. provide and install (9) 3" floor sinks, (5) 3" floor drains, & (1) 4"x7' trench drain with trap seals in fixtures per city code 5. install gas service from meter to gas appliances per plan, final appliance connection to gas stop provided by installer 6. gc will provide all rooftop vent and gas penetrations as needed, gc to install rooftop flashings and seal penetrations 7. install tankless water heaters on wall with dual horizontal vent piping through wall, gc to patch wall as needed 8. install pvc drain & pex water connections at all sinks & toilets per plan, commercial equipment & sink install by provider 9. core cement deck as needed for drain and water penetrations. gc to provide metal pan cutting below cores as needed 10. bid includes single roof drain and overflow drain with separate discharge down from roof to terminate 6" above grade 11. bid includes 3/4" hose bib and 2" pvc capped drain stub out at aquarium location, final connections provided by others 12. bid inlcudes 1 total watts hy-725 3/4" exterior frostproof hydrant with locking box, gc to provide frame for mounting 13. install 2" rpz with air gap & strainer on water main in riser closet. fire system water main above & below grade not inlcuded 14. install 1 1/2" pvc pump discharge line from elevator closet to water heater floor sink, pump & connection by others 15. install fire suppression anzel valve on gas supply, valve provided by others. safety button system installed by others 16. install aav on island sink locations per city code. loop vent systems are not included at island fixture locations 17. bid includes fixture trim per schedule below with pex crimp water stops and tubular drain connections per code 18. any additional plumbing not included in bid and requested by gc is billed as t&m on separate change order

    City of Dallas permitCommercial Plumbing Permit
    Record
    COM-PLM-26-003750
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  3. Renovation alteration of existing office space into new restaurant for clarks oyster bar within the existing building footprint

    Renovation alteration of existing office space into new restaurant for clarks oyster bar within the existing building footprint

    City of Dallas permitCommercial Alteration Addition Permit
    Record
    COM-ALT-ADD-26-001116
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro

Sources: City of Dallas

Questions about 4155 Buena Vista St

What is being built at 4155 Buena Vista St in Dallas?

A City of Dallas permit describes a renovation converting existing office space into a restaurant for Clark's Oyster Bar. The work is within the existing building footprint.

When was the restaurant project at 4155 Buena Vista permitted?

The commercial alteration permit, COM-ALT-ADD-26-001116, was filed August 4, 2026. Plumbing and electrical permits were filed September 21, 2026.

Is Clark's Oyster Bar opening at 4155 Buena Vista?

The August 4, 2026, permit describes renovations for a new restaurant for Clark's Oyster Bar. The records do not give an opening date.

What work is planned at 4155 Buena Vista?

The September 21 plumbing permit lists water and sewer service, drains, floor sinks, and connections for fixtures and appliances. An electrical installation permit was also filed that day.

What's going in near James Perse on N Fitzhugh Avenue?

A restaurant for Clark's Oyster Bar is planned in existing office space at 4155 Buena Vista St, about 104 meters from James Perse - Dallas. The alteration permit was filed August 4, 2026.

Is the restaurant at 4155 Buena Vista a new building?

No new building is described in the permit. It calls for renovating existing office space into restaurant space within the existing building footprint.