5625 Village Glen Dr
Dallas, TX 75206
Office space at 5625 Village Glen Dr is being converted to hotel use
City of Dallas permits indicate that office space at 5625 Village Glen Dr is being remodeled and converted to hotel use. The first listed filing was September 25, 2025, and permits filed through December 24 describe work for Village Glen Hotel and Village Drey Hotel, including electrical and mechanical work.
Summarized from City of Dallas records · updated Dec 24, 2025
- Projects
- 20
- 20 filings
- Latest filing
- Dec 24, 2025
- since Sep 25, 2025
- Largest scope
- —
- Listed value
- —
Permit & project history
20 projectsO demolition of the following:? (7) vrv’s- with associated piping? (8) electric unit heaters? (3) grease exhaust fans? ductwork as shown on mechanical sheetso relocation of the following:? (3) vrv indoor condensing units• assumes condenser water piping to be ran from nearest supply and return main lines? (2) vrv branch selectors? (8) vrv fan coil units• count is based off trane assessment of existing conditions of vrv units shown to be reused. o provision & installation of the following:? (25) vrv fan coil units? (1) vrv branch selector box? (1) doas? (1) exhaust fan? (1) sound attenuators? (1) fire damper? roof curbs, hangers and supports as specified? ductwork with insulation? fire stopping for mechanical items? grilles, registers, and diffusers with flex duct? vrv piping to accommodate new and relocated fan coil units and branch selectors? new condenser water piping from main lines to relocated condensing units• size per our design – clarification from telios needed? condensate drain pipingo vibration isolation as specifiedo mechanical identification
O demolition of the following:? (7) vrv’s- with associated piping? (8) electric unit heaters? (3) grease exhaust fans? ductwork as shown on mechanical sheetso relocation of the following:? (3) vrv indoor condensing units• assumes condenser water piping to be ran from nearest supply and return main lines? (2) vrv branch selectors? (8) vrv fan coil units• count is based off trane assessment of existing conditions of vrv units shown to be reused. o provision & installation of the following:? (25) vrv fan coil units? (1) vrv branch selector box? (1) doas? (1) exhaust fan? (1) sound attenuators? (1) fire damper? roof curbs, hangers and supports as specified? ductwork with insulation? fire stopping for mechanical items? grilles, registers, and diffusers with flex duct? vrv piping to accommodate new and relocated fan coil units and branch selectors? new condenser water piping from main lines to relocated condensing units• size per our design – clarification from telios needed? condensate drain pipingo vibration isolation as specifiedo mechanical identification
City of Dallas permitCommercial Mechanical Permit• floors 1 & 2:o demolition of the following:? (15) vrv’s- with associated piping? ductwork as shown on mechanical sheetso relocation of the following:? (8) vrv fan coil units• count is based off trane assessment of existing conditions of vrv units shown to be reused. o provision & installation of the following:? (18) vrv fan coil units? (1) sound attenuators? hangers and supports as specified? ductwork with insulation? fire stopping for mechanical items? grilles, registers, and diffusers with flex duct? vrv piping to accommodate new and relocated fan coil units and branch selectors? condensate drain pipingo vibration isolation as specifiedo mechanical identification
• floors 1 & 2:o demolition of the following:? (15) vrv’s- with associated piping? ductwork as shown on mechanical sheetso relocation of the following:? (8) vrv fan coil units• count is based off trane assessment of existing conditions of vrv units shown to be reused. o provision & installation of the following:? (18) vrv fan coil units? (1) sound attenuators? hangers and supports as specified? ductwork with insulation? fire stopping for mechanical items? grilles, registers, and diffusers with flex duct? vrv piping to accommodate new and relocated fan coil units and branch selectors? condensate drain pipingo vibration isolation as specifiedo mechanical identification
City of Dallas permitCommercial Mechanical PermitO demolition of the following:? (7) vrv’s- with associated piping? (8) electric unit heaters? (3) grease exhaust fans? ductwork as shown on mechanical sheetso relocation of the following:? (3) vrv indoor condensing units• assumes condenser water piping to be ran from nearest supply and return main lines? (2) vrv branch selectors? (8) vrv fan coil units• count is based off trane assessment of existing conditions of vrv units shown to be reused. o provision & installation of the following:? (25) vrv fan coil units? (1) vrv branch selector box? (1) doas? (1) exhaust fan? (1) sound attenuators? (1) fire damper? roof curbs, hangers and supports as specified? ductwork with insulation? fire stopping for mechanical items? grilles, registers, and diffusers with flex duct? vrv piping to accommodate new and relocated fan coil units and branch selectors? new condenser water piping from main lines to relocated condensing units• size per our design – clarification from telios needed? condensate drain pipingo vibration isolation as specifiedo mechanical identification
O demolition of the following:? (7) vrv’s- with associated piping? (8) electric unit heaters? (3) grease exhaust fans? ductwork as shown on mechanical sheetso relocation of the following:? (3) vrv indoor condensing units• assumes condenser water piping to be ran from nearest supply and return main lines? (2) vrv branch selectors? (8) vrv fan coil units• count is based off trane assessment of existing conditions of vrv units shown to be reused. o provision & installation of the following:? (25) vrv fan coil units? (1) vrv branch selector box? (1) doas? (1) exhaust fan? (1) sound attenuators? (1) fire damper? roof curbs, hangers and supports as specified? ductwork with insulation? fire stopping for mechanical items? grilles, registers, and diffusers with flex duct? vrv piping to accommodate new and relocated fan coil units and branch selectors? new condenser water piping from main lines to relocated condensing units• size per our design – clarification from telios needed? condensate drain pipingo vibration isolation as specifiedo mechanical identification
City of Dallas permitCommercial Mechanical PermitO demolition of the following:? (15) vrv’s- with associated piping? ductwork as shown on mechanical sheetso relocation of the following:? (8) vrv fan coil units• count is based off trane assessment of existing conditions of vrv units shown to be reused. o provision & installation of the following:? (18) vrv fan coil units? (1) sound attenuators? hangers and supports as specified? ductwork with insulation? fire stopping for mechanical items? grilles, registers, and diffusers with flex duct? vrv piping to accommodate new and relocated fan coil units and branch selectors? condensate drain pipingo vibration isolation as specifiedo mechanical identification
O demolition of the following:? (15) vrv’s- with associated piping? ductwork as shown on mechanical sheetso relocation of the following:? (8) vrv fan coil units• count is based off trane assessment of existing conditions of vrv units shown to be reused. o provision & installation of the following:? (18) vrv fan coil units? (1) sound attenuators? hangers and supports as specified? ductwork with insulation? fire stopping for mechanical items? grilles, registers, and diffusers with flex duct? vrv piping to accommodate new and relocated fan coil units and branch selectors? condensate drain pipingo vibration isolation as specifiedo mechanical identification
City of Dallas permitCommercial Mechanical PermitDemolition 2nd floor rr plumbing & cap as necessary. rough-in and top out for lav, shower, wc, bt, fd. provide new sewer for wc, lav, shower
Demolition 2nd floor rr plumbing & cap as necessary. rough-in and top out for lav, shower, wc, bt, fd. provide new sewer for wc, lav, shower
City of Dallas permitCommercial Plumbing PermitDemolition 3rd floor rr plumbing. demolition 3rd floor storm & pipe. provide new sewer for fixtures. install new fixtures
Demolition 3rd floor rr plumbing. demolition 3rd floor storm & pipe. provide new sewer for fixtures. install new fixtures
City of Dallas permitCommercial Plumbing Permit
Sources: City of Dallas
Questions about 5625 Village Glen Dr
What is being built at 5625 Village Glen Dr?
City of Dallas permit descriptions indicate that office space is being remodeled and converted to hotel use. Records refer to Village Glen Hotel and Village Drey Hotel.
When were permits filed for the hotel conversion at 5625 Village Glen Dr?
The records list filings from September 25 through December 24, 2025. Several electrical permits for hotel work were filed on December 24.
Is 5625 Village Glen Dr a new hotel?
Permits describe remodeling and converting office space to hotel use. They do not provide an opening date or identify a hotel brand.
What work is planned for the building at 5625 Village Glen Dr?
Permit descriptions include electrical and mechanical work, such as installing and relocating fan coil units and related equipment. Plumbing permits also describe restroom demolition and new plumbing connections.
What are the permit numbers for the hotel work at 5625 Village Glen Dr?
Electrical permits filed December 24, 2025, include COM-ELC-25-003802, COM-ELC-25-003798, COM-ELC-25-003799 and COM-ELC-25-003803. Mechanical permits filed October 9 include COM-MEC-25-000932 through COM-MEC-25-000935.
Also being built nearby
All of 75206- 5650 Village Glen DrOct 24, 2025Ductwork and rtu for existing structure the meridian to the patio area “ · 74 m away
- 5882 Caruth Haven LnDec 12, 2025Backflow device replacement and installation (rpz) · 104 m away
- 8297 Southwestern BlvdNov 20, 2020Electric service for traffic signals · 125 m away
- 5670 Village Glen DrAug 7, 2025Adding kitchen/break room sinkice maker boxesbi level water cooler · 132 m away
- 5677 Village Glen DrFeb 11, 2026Mcr address use to be a residential, now 1st floor is a business. it was changed to a nail salon · 160 m away
- 6212 Shady Brook LnNov 25, 2020Electric service for traffic signals · 201 m away
- 5971 Caruth Haven LnOct 22, 2020Installation of 7 access control doors that have free egress locking hardware for p1 · 260 m away
- 5963 Caruth Haven LnOct 22, 2020Installation of two access control doors that have free egress locking hardware installed · 262 m away
- 5955 Caruth Haven LnOct 24, 2020Installation of 1 access control door that has free egress door hardware installed on it · 265 m away
- 8583 Southwestern BlvdOct 12, 2026Removal and replacement of full property asphalt shingle system down to decking. inspect decking and replace as needed · 306 m away
- 6302 Shady Brook LnJan 27, 2021Electrical repairs · 306 m away
- 6130 Greenville AveSep 29, 2025No service, no work · 375 m away
More demolitions in 75206, hotels in 75206, offices in 75206.