groundranger
Recent · latest filing Apr 2026Residential

3337 Walchard Ct

Dallas, TX 75229

New home construction at 3337 Walchard Ct

City of Dallas permits indicate new residential construction at 3337 Walchard Ct, including plumbing, mechanical and electrical work. The first listed permit was filed July 21, 2025, and the latest, for electrical work for new construction, was filed April 22, 2026.

Summarized from City of Dallas records · updated Apr 22, 2026

Projects
6
6 filings
Latest filing
Apr 22, 2026
since Jul 21, 2025
Largest scope
—
Listed value
—

Permit & project history

6 projects
  1. Electrical for new construction

    Electrical for new construction

    City of Dallas permitResidential Electrical Permit
    Record
    RES-ELC-26-002283
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  2. Contractor to perform grading and preparation for new concrete driveway installation. scope includes excavation and leveling of driveway area to proper elevation and slope for drainage, compaction of subgrade, and installation of base material as required. contractor to saw-cut and remove existing curb as needed for driveway approach, ensuring proper tie-in to street and compliance with city requirements. final preparation to meet pre-pour inspection standards prior to concrete placement

    Contractor to perform grading and preparation for new concrete driveway installation. scope includes excavation and leveling of driveway area to proper elevation and slope for drainage, compaction of subgrade, and installation of base material as required. contractor to saw-cut and remove existing curb as needed for driveway approach, ensuring proper tie-in to street and compliance with city requirements. final preparation to meet pre-pour inspection standards prior to concrete placement

    City of Dallas permitResidential Drive Approach and Sidewalk Permit
    Record
    RES-DSW-26-000089
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  3. New plumbing work for 12 fixtures and 4 gas openings

    New plumbing work for 12 fixtures and 4 gas openings

    City of Dallas permitResidential Plumbing Permit
    Record
    RES-PLM-25-006931
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  4. Installartion of 2 4 tons unit and duct work

    Installartion of 2 4 tons unit and duct work

    City of Dallas permitResidential Mechanical Permit
    Record
    RES-MEC-25-003256
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  5. 1.) verify all exterior electrical, floor plugs, phone & tv jacks, security & sound system wiring with the owner before the construction project.2.) install arc fault circuit interrupter protection for all sleeping rooms.3.) dedicated circuits for all appliances.4.) provide switched lighting & 110 volt receptacle in the attic @ mechanical platform.5.) install outside emergency disconnect that is clearly labeled.6.) all outdoor outlets to be gfci.7.) all outlets in the kitchen, areas with a sink, and food preparation areas to be gfci.8.) all work must comply with the current city- adopted electrical code.9.) electrical panels shall not be located in closets, bathrooms, or stairways

    1.) verify all exterior electrical, floor plugs, phone & tv jacks, security & sound system wiring with the owner before the construction project.2.) install arc fault circuit interrupter protection for all sleeping rooms.3.) dedicated circuits for all appliances.4.) provide switched lighting & 110 volt receptacle in the attic @ mechanical platform.5.) install outside emergency disconnect that is clearly labeled.6.) all outdoor outlets to be gfci.7.) all outlets in the kitchen, areas with a sink, and food preparation areas to be gfci.8.) all work must comply with the current city- adopted electrical code.9.) electrical panels shall not be located in closets, bathrooms, or stairways

    City of Dallas permitResidential Electrical Permit
    Record
    RES-ELC-25-001847
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  6. New construction plumbing

    New construction plumbing

    City of Dallas permitResidential Plumbing Permit
    Record
    RES-PLM-25-002736
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro

Sources: City of Dallas

Questions about 3337 Walchard Ct

What is being built at 3337 Walchard Ct?

City of Dallas permits indicate new residential construction. The records include new plumbing, mechanical work and electrical work for new construction.

When was construction first permitted at 3337 Walchard Ct?

The earliest permit in the records was filed July 21, 2025. It was a residential plumbing permit for new construction, RES-PLM-25-002736.

What is the latest permit for 3337 Walchard Ct?

The latest listed permit was filed April 22, 2026, for electrical work for new construction. Its permit number is RES-ELC-26-002283.

What plumbing work is permitted at 3337 Walchard Ct?

A November 3, 2025, residential plumbing permit covers work for 12 fixtures and four gas openings. The permit number is RES-PLM-25-006931.

What mechanical work is planned at 3337 Walchard Ct?

A residential mechanical permit filed October 22, 2025, describes installation of two four-ton units and ductwork. The permit number is RES-MEC-25-003256.

Is there driveway work permitted at 3337 Walchard Ct?

A February 24, 2026, permit covers grading and preparation for a new concrete driveway, including excavation and driveway-approach work. The permit number is RES-DSW-26-000089.

Also being built nearby

All of 75229

More restaurants in 75229.

Get alerts for 3337 Walchard Ct