Commercial building repairs and interior work at 1420 Viceroy Dr

Dallas permits indicate repair and alteration work at the commercial building at 1420 Viceroy Dr, with filings from September 4, 2025, through September 18, 2026. The records describe roof work, repairs to interior walls, plumbing for sinks and floor drains, and additional electrical outlets. No occupant or tenant is identified.

Summarized from City of Dallas records · updated Sep 18, 2026

Projects
6
6 filings
Latest filing
Sep 18, 2026
since Sep 4, 2025
Largest scope
—
Listed value
—

Permit & project history

6 projects
  1. Install additional plugs were needed

    Install additional plugs were needed

    City of Dallas permitCommercial Electrical Permit
    Record
    COM-ELC-26-004713
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  2. We purchased this building, which had been vandalized and had water damage. the prior owner completed work on the building before we purchased it. we are only adding sheetrock back to the current walls. individual permits have already been established. we have been applying for the co but keep getting denied. we have had an architect come in and create the drawings

    We purchased this building, which had been vandalized and had water damage. the prior owner completed work on the building before we purchased it. we are only adding sheetrock back to the current walls. individual permits have already been established. we have been applying for the co but keep getting denied. we have had an architect come in and create the drawings

    City of Dallas permitCommercial Alteration Addition Permit
    Record
    COM-ALT-ADD-26-001979
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  3. Installing floor drainsdrains to sinkand water lines to sink

    Installing floor drainsdrains to sinkand water lines to sink

    City of Dallas permitCommercial Plumbing Permit
    Record
    COM-PLM-26-002406
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  4. Enclose both sides of the building with wrought iron fence, 8 feet tall, 2 sliding driveway gates and 1 walk through gate

    Enclose both sides of the building with wrought iron fence, 8 feet tall, 2 sliding driveway gates and 1 walk through gate

    City of Dallas permitCommercial Accessory Structure Permit
    Record
    COM-ACC-25-000126
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  5. Repair electrical service due to theft

    Repair electrical service due to theft

    City of Dallas permitCommercial Electrical Permit
    Record
    COM-ELC-25-001933
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  6. Demolition existing metal copingdemo existing wall flashinginspect the brick that is exposed.removal of gravel from the roof by vacuumspud and clean gravel make it a.5smooth surfaceinstallation of 1 layer 1" of polyisocyanurate (polyiso) mechanically attachedto deck.adhere thermoplastic polyolefin (tpo),.60 mil white color membrane.adhere thermoplastic polyolefin (tpo),.60 mil white color membrane on innerparapet wallprovide and install 60 ea prefabricated inside/outside cornersprovide and install 12 ea prefabricated pipe boots.provide and install 12 ea prefabricated pitch pans.provide and install 692 lf of termination bar.fabricate and install 692 lf 22 22-gauge galvanized counter flashing.fabricate and install a 24-gauge tpo-coated metal scupperfabricate and install a 24-gauge collector box with standard color kynar finishfabricate and install 24 ga kynar finish standard color downspoutsfabricate and install 22 ga galvanized cleat for metal coping.fabricate and install 24 ga kynar finish metal coping standard color.fabricate and install 22 ga galvanized metal cleat for the fascia platefabricate and install 24 ga kynar finish standard color fascia platereplace shingled roof of carport with like product, in accordance with manufacturer instructions and applicable code

    Demolition existing metal copingdemo existing wall flashinginspect the brick that is exposed.removal of gravel from the roof by vacuumspud and clean gravel make it a.5smooth surfaceinstallation of 1 layer 1" of polyisocyanurate (polyiso) mechanically attachedto deck.adhere thermoplastic polyolefin (tpo),.60 mil white color membrane.adhere thermoplastic polyolefin (tpo),.60 mil white color membrane on innerparapet wallprovide and install 60 ea prefabricated inside/outside cornersprovide and install 12 ea prefabricated pipe boots.provide and install 12 ea prefabricated pitch pans.provide and install 692 lf of termination bar.fabricate and install 692 lf 22 22-gauge galvanized counter flashing.fabricate and install a 24-gauge tpo-coated metal scupperfabricate and install a 24-gauge collector box with standard color kynar finishfabricate and install 24 ga kynar finish standard color downspoutsfabricate and install 22 ga galvanized cleat for metal coping.fabricate and install 24 ga kynar finish metal coping standard color.fabricate and install 22 ga galvanized metal cleat for the fascia platefabricate and install 24 ga kynar finish standard color fascia platereplace shingled roof of carport with like product, in accordance with manufacturer instructions and applicable code

    City of Dallas permitCommercial Roofing Permit
    Record
    COM-ROOF-25-000120
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro

Sources: City of Dallas

Questions about 1420 Viceroy Dr

What is being built at 1420 Viceroy Dr in Dallas?

Dallas permit records describe repairs and alteration work at an existing commercial building, including roof work, interior wall repairs, plumbing and added electrical outlets. The records do not identify a new building or a named occupant.

Is a restaurant opening at 1420 Viceroy Dr?

The records include plumbing work for sinks and floor drains, but they do not name a restaurant or confirm an opening. The permits most recently listed are for plumbing on August 7, 2026, and added electrical outlets on September 18, 2026.

What work permits have been filed for 1420 Viceroy Dr?

Dallas records include permits for roofing, electrical repairs, fencing, plumbing, and commercial alterations. The alteration permit, COM-ALT-ADD-26-001979, was filed August 24, 2026.

When were permits filed for 1420 Viceroy Dr?

The records span September 4, 2025, through September 18, 2026. The earliest listed permits cover roof work and electrical service repairs; the latest is for additional electrical outlets.

What's being renovated near Extended Stay 4 Story Hotel on Viceroy Drive?

At 1420 Viceroy Dr, Dallas permits describe repairs and alterations to a commercial building. The hotel at 8830 N Stemmons Freeway is listed about 171 meters away.

Who is the tenant at 1420 Viceroy Dr?

The permit records do not identify an occupant or tenant for 1420 Viceroy Dr.