groundranger
Active · latest filing Nov 2026Commercial

10851 Miller Rd

Dallas, TX 75238

Warehouse construction and spec office fit-outs at 10851 Miller Rd

City of Dallas permits indicate warehouse shell construction and spec office space at 10851 Miller Rd. Plumbing permits for shell-building work were filed in June 2026, and office finish-out permits were filed in October and November 2026. Mechanical permits describe warehouse buildings 1A, 1B and 2.

Summarized from City of Dallas records · updated Nov 13, 2026

Projects
16
16 filings
Latest filing
Nov 13, 2026
since Nov 13, 2026
Largest scope
—
Listed value
—

Permit & project history

16 projects
  1. Qteam inhouse first time finish out for spec office

    Qteam inhouse first time finish out for spec office

    City of Dallas permitCommercial New Construction Permit
    Record
    COM-NEW-26-000350
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  2. Qteam inhouse upgraded electrical service for suite 100

    Qteam inhouse upgraded electrical service for suite 100

    City of Dallas permitCommercial New Construction Permit
    Record
    COM-NEW-26-000339
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  3. First time finish out for spec office space

    First time finish out for spec office space

    City of Dallas permitCommercial Alteration Addition Permit
    Record
    COM-ALT-ADD-26-002597
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  4. Electrical installation for commercial project

    Electrical installation for commercial project

    City of Dallas permitCommercial Electrical Permit
    Record
    COM-ELC-26-005219
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  5. Electrical installation for commercial project

    Electrical installation for commercial project

    City of Dallas permitCommercial Electrical Permit
    Record
    COM-ELC-26-005217
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  6. Provision & installation of the following:• warehouse (building. 1b):• (6) gas fired unit heater(s) with spark ignition, power vent and standard thermostat, 350 mbh input each, 120/1/60• (5) roof mounted propeller exhaust fan(s), complete with high temperature rating, 35,000 cfm, standard insulated flat factory curb, magnetic damper latches, and nema-3 service disconnect, 7.5 hp 460/3/60• (1) unrated roof mounted propeller exhaust fan(s), complete with 15,000 cfm, standard insulated flat factory curb, butterfly backdraft damper, magnetic damper latches and nema-3 service disconnect, 3 hp 460/3/60• (5) wall mounted adjustable louver(s) (96” x 120” x 6”) of extruded aluminum construction complete with mill finish, motor operator(s) and birdscreen, 120/1/60• pump room:• (1) 5kw electric unit heater with mounting bracket and integral thermostat, 460/3/60• (1) roof mounted exhaust fan with fractional hp motor, nema-1 service disconnect, roof curb, and gravity backdraft damper• (1) rectangular duct drop with fire damper (if required at the lid of the pump room)• (1) wall mounted adjustable louver (24” x 24” x 6”) of extruded aluminum construction complete with mill finish, motor operator and birdscreen, 120/1/60• note: this pump room design is based on an electric fire pump

    Provision & installation of the following:• warehouse (building. 1b):• (6) gas fired unit heater(s) with spark ignition, power vent and standard thermostat, 350 mbh input each, 120/1/60• (5) roof mounted propeller exhaust fan(s), complete with high temperature rating, 35,000 cfm, standard insulated flat factory curb, magnetic damper latches, and nema-3 service disconnect, 7.5 hp 460/3/60• (1) unrated roof mounted propeller exhaust fan(s), complete with 15,000 cfm, standard insulated flat factory curb, butterfly backdraft damper, magnetic damper latches and nema-3 service disconnect, 3 hp 460/3/60• (5) wall mounted adjustable louver(s) (96” x 120” x 6”) of extruded aluminum construction complete with mill finish, motor operator(s) and birdscreen, 120/1/60• pump room:• (1) 5kw electric unit heater with mounting bracket and integral thermostat, 460/3/60• (1) roof mounted exhaust fan with fractional hp motor, nema-1 service disconnect, roof curb, and gravity backdraft damper• (1) rectangular duct drop with fire damper (if required at the lid of the pump room)• (1) wall mounted adjustable louver (24” x 24” x 6”) of extruded aluminum construction complete with mill finish, motor operator and birdscreen, 120/1/60• note: this pump room design is based on an electric fire pump

    City of Dallas permitCommercial Mechanical Permit
    Record
    COM-MEC-26-001509
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  7. • provision & installation of the following:• warehouse (building. 1a):• (6) gas fired unit heater(s) with spark ignition, power vent and standard thermostat, 300 mbh input each, 120/1/60• (5) roof mounted propeller exhaust fan(s), complete with high temperature rating, 35,000 cfm, standard insulated flat factory curb, magnetic damper latches, and nema-3 service disconnect, 7.5 hp 460/3/60• (1) unrated roof mounted propeller exhaust fan(s), complete with 15,000 cfm, standard insulated flat factory curb, butterfly backdraft damper, magnetic damper latches and nema-3 service disconnect, 3 hp 460/3/60• (5) wall mounted adjustable louver(s) (96” x 120” x 6”) of extruded aluminum construction complete with mill finish, motor operator(s) and birdscreen, 120/1/60• pump room:• (1) 5kw electric unit heater with mounting bracket and integral thermostat, 460/3/60• (1) roof mounted exhaust fan with fractional hp motor, nema-1 service disconnect, roof curb, and gravity backdraft damper• (1) rectangular duct drop with fire damper (if required at the lid of the pump room)• (1) wall mounted adjustable louver (24” x 24” x 6”) of extruded aluminum construction complete with mill finish, motor operator and birdscreen, 120/1/60• note: this pump room design is based on an electric fire pump

    • provision & installation of the following:• warehouse (building. 1a):• (6) gas fired unit heater(s) with spark ignition, power vent and standard thermostat, 300 mbh input each, 120/1/60• (5) roof mounted propeller exhaust fan(s), complete with high temperature rating, 35,000 cfm, standard insulated flat factory curb, magnetic damper latches, and nema-3 service disconnect, 7.5 hp 460/3/60• (1) unrated roof mounted propeller exhaust fan(s), complete with 15,000 cfm, standard insulated flat factory curb, butterfly backdraft damper, magnetic damper latches and nema-3 service disconnect, 3 hp 460/3/60• (5) wall mounted adjustable louver(s) (96” x 120” x 6”) of extruded aluminum construction complete with mill finish, motor operator(s) and birdscreen, 120/1/60• pump room:• (1) 5kw electric unit heater with mounting bracket and integral thermostat, 460/3/60• (1) roof mounted exhaust fan with fractional hp motor, nema-1 service disconnect, roof curb, and gravity backdraft damper• (1) rectangular duct drop with fire damper (if required at the lid of the pump room)• (1) wall mounted adjustable louver (24” x 24” x 6”) of extruded aluminum construction complete with mill finish, motor operator and birdscreen, 120/1/60• note: this pump room design is based on an electric fire pump

    City of Dallas permitCommercial Mechanical Permit
    Record
    COM-MEC-26-001508
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  8. • warehouse (building. 1a):• (6) gas fired unit heater(s) with spark ignition, power vent and standard thermostat, 300 mbh input each, 120/1/60• (5) roof mounted propeller exhaust fan(s), complete with high temperature rating, 35,000 cfm, standard insulated flat factory curb, magnetic damper latches, and nema-3 service disconnect, 7.5 hp 460/3/60• (1) unrated roof mounted propeller exhaust fan(s), complete with 15,000 cfm, standard insulated flat factory curb, butterfly backdraft damper, magnetic damper latches and nema-3 service disconnect, 3 hp 460/3/60• (5) wall mounted adjustable louver(s) (96” x 120” x 6”) of extruded aluminum construction complete with mill finish, motor operator(s) and birdscreen, 120/1/60• pump room:• (1) 5kw electric unit heater with mounting bracket and integral thermostat, 460/3/60• (1) roof mounted exhaust fan with fractional hp motor, nema-1 service disconnect, roof curb, and gravity backdraft damper• (1) rectangular duct drop with fire damper (if required at the lid of the pump room)• (1) wall mounted adjustable louver (24” x 24” x 6”) of extruded aluminum construction complete with mill finish, motor operator and birdscreen, 120/1/60• note: this pump room design is based on an electric fire pump.• warehouse (building. 1b):• (6) gas fired unit heater(s) with spark ignition, power vent and standard thermostat, 350 mbh input each, 120/1/60• (5) roof mounted propeller exhaust fan(s), complete with high temperature rating, 35,000 cfm, standard insulated flat factory curb, magnetic damper latches, and nema-3 service disconnect, 7.5 hp 460/3/60• (1) unrated roof mounted propeller exhaust fan(s), complete with 15,000 cfm, standard insulated flat factory curb, butterfly backdraft damper, magnetic damper latches and nema-3 service disconnect, 3 hp 460/3/60• (5) wall mounted adjustable louver(s) (96” x 120” x 6”) of extruded aluminum construction complete with mill finish, motor operator(s) and birdscreen, 120/1/60• pump room:• (1) 5kw electric unit heater with mounting bracket and integral thermostat, 460/3/60• (1) roof mounted exhaust fan with fractional hp motor, nema-1 service disconnect, roof curb, and gravity backdraft damper• (1) rectangular duct drop with fire damper (if required at the lid of the pump room)• (1) wall mounted adjustable louver (24” x 24” x 6”) of extruded aluminum construction complete with mill finish, motor operator and birdscreen, 120/1/60• note: this pump room design is based on an electric fire pump.• warehouse (building. 2):• (6) gas fired unit heater(s) with spark ignition, power vent and standard thermostat, 300 mbh input each, 120/1/60• (5) roof mounted propeller exhaust fan(s), complete with high temperature rating, 35,000 cfm, standard insulated flat factory curb, magnetic damper latches, and nema-3 service disconnect, 7.5 hp 460/3/60• (1) unrated roof mounted propeller exhaust fan(s), complete with 15,000 cfm, standard insulated flat factory curb, butterfly backdraft damper, magnetic damper latches and nema-3 service disconnect, 3 hp 460/3/60• (5) wall mounted adjustable louver(s) (96” x 120” x 6”) of extruded aluminum construction complete with mill finish, motor operator(s) and birdscreen, 120/1/60• pump room:• (1) 5kw electric unit heater with mounting bracket and integral thermostat, 460/3/60• (1) roof mounted exhaust fan with fractional hp motor, nema-1 service disconnect, roof curb, and gravity backdraft damper• (1) rectangular duct drop with fire damper (if required at the lid of the pump room)• (1) wall mounted adjustable louver (24” x 24” x 6”) of extruded aluminum construction complete with mill finish, motor operator and birdscreen, 120/1/60• note: this pump room design is based on an electric fire pump.• provision (only), of the following:• (1) line voltage thermostat for pump room ventilation system – installed by electrician

    • warehouse (building. 1a):• (6) gas fired unit heater(s) with spark ignition, power vent and standard thermostat, 300 mbh input each, 120/1/60• (5) roof mounted propeller exhaust fan(s), complete with high temperature rating, 35,000 cfm, standard insulated flat factory curb, magnetic damper latches, and nema-3 service disconnect, 7.5 hp 460/3/60• (1) unrated roof mounted propeller exhaust fan(s), complete with 15,000 cfm, standard insulated flat factory curb, butterfly backdraft damper, magnetic damper latches and nema-3 service disconnect, 3 hp 460/3/60• (5) wall mounted adjustable louver(s) (96” x 120” x 6”) of extruded aluminum construction complete with mill finish, motor operator(s) and birdscreen, 120/1/60• pump room:• (1) 5kw electric unit heater with mounting bracket and integral thermostat, 460/3/60• (1) roof mounted exhaust fan with fractional hp motor, nema-1 service disconnect, roof curb, and gravity backdraft damper• (1) rectangular duct drop with fire damper (if required at the lid of the pump room)• (1) wall mounted adjustable louver (24” x 24” x 6”) of extruded aluminum construction complete with mill finish, motor operator and birdscreen, 120/1/60• note: this pump room design is based on an electric fire pump.• warehouse (building. 1b):• (6) gas fired unit heater(s) with spark ignition, power vent and standard thermostat, 350 mbh input each, 120/1/60• (5) roof mounted propeller exhaust fan(s), complete with high temperature rating, 35,000 cfm, standard insulated flat factory curb, magnetic damper latches, and nema-3 service disconnect, 7.5 hp 460/3/60• (1) unrated roof mounted propeller exhaust fan(s), complete with 15,000 cfm, standard insulated flat factory curb, butterfly backdraft damper, magnetic damper latches and nema-3 service disconnect, 3 hp 460/3/60• (5) wall mounted adjustable louver(s) (96” x 120” x 6”) of extruded aluminum construction complete with mill finish, motor operator(s) and birdscreen, 120/1/60• pump room:• (1) 5kw electric unit heater with mounting bracket and integral thermostat, 460/3/60• (1) roof mounted exhaust fan with fractional hp motor, nema-1 service disconnect, roof curb, and gravity backdraft damper• (1) rectangular duct drop with fire damper (if required at the lid of the pump room)• (1) wall mounted adjustable louver (24” x 24” x 6”) of extruded aluminum construction complete with mill finish, motor operator and birdscreen, 120/1/60• note: this pump room design is based on an electric fire pump.• warehouse (building. 2):• (6) gas fired unit heater(s) with spark ignition, power vent and standard thermostat, 300 mbh input each, 120/1/60• (5) roof mounted propeller exhaust fan(s), complete with high temperature rating, 35,000 cfm, standard insulated flat factory curb, magnetic damper latches, and nema-3 service disconnect, 7.5 hp 460/3/60• (1) unrated roof mounted propeller exhaust fan(s), complete with 15,000 cfm, standard insulated flat factory curb, butterfly backdraft damper, magnetic damper latches and nema-3 service disconnect, 3 hp 460/3/60• (5) wall mounted adjustable louver(s) (96” x 120” x 6”) of extruded aluminum construction complete with mill finish, motor operator(s) and birdscreen, 120/1/60• pump room:• (1) 5kw electric unit heater with mounting bracket and integral thermostat, 460/3/60• (1) roof mounted exhaust fan with fractional hp motor, nema-1 service disconnect, roof curb, and gravity backdraft damper• (1) rectangular duct drop with fire damper (if required at the lid of the pump room)• (1) wall mounted adjustable louver (24” x 24” x 6”) of extruded aluminum construction complete with mill finish, motor operator and birdscreen, 120/1/60• note: this pump room design is based on an electric fire pump.• provision (only), of the following:• (1) line voltage thermostat for pump room ventilation system – installed by electrician

    City of Dallas permitCommercial Mechanical Permit
    Record
    COM-MEC-26-001500
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  9. 205 lf of 6" pvc sewer laterals from with cleanouts from easement to building 2.73 lf of 4" domestic water service from meter to 5 feet from building 2

    205 lf of 6" pvc sewer laterals from with cleanouts from easement to building 2.73 lf of 4" domestic water service from meter to 5 feet from building 2

    City of Dallas permitCommercial Plumbing Permit
    Record
    COM-PLM-26-002262
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  10. 205 lf of 6" pvc sewer laterals "v", "t", and "r" from cleanouts on the easement line towards the building.33 lf of 4" domestic water line from the public meter easement to 5 from building

    205 lf of 6" pvc sewer laterals "v", "t", and "r" from cleanouts on the easement line towards the building.33 lf of 4" domestic water line from the public meter easement to 5 from building

    City of Dallas permitCommercial Plumbing Permit
    Record
    COM-PLM-26-002261
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  11. Ground up shell building., sewer, water, gas

    Ground up shell building., sewer, water, gas

    City of Dallas permitCommercial Plumbing Permit
    Record
    COM-PLM-26-002095
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  12. Sewer, water, gas

    Sewer, water, gas

    City of Dallas permitCommercial Plumbing Permit
    Record
    COM-PLM-26-002084
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  13. Qteam meeting 3.3.2026 (9am) b1 shell construction of a shell warehouse

    Qteam meeting 3.3.2026 (9am) b1 shell construction of a shell warehouse

    City of Dallas permitCommercial New Construction Permit
    Record
    COM-NEW-26-000028
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  14. 1900' - 42" high black chain link, no gates

    1900' - 42" high black chain link, no gates

    City of Dallas permitCommercial Accessory Structure Permit
    Record
    COM-ACC-26-000055
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  15. Construct 1886lf of stone retaining walls

    Construct 1886lf of stone retaining walls

    City of Dallas permitCommercial Accessory Structure Permit
    Record
    COM-ACC-26-000011
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  16. Electrical work associated with building permit 2210241062

    Electrical work associated with building permit 2210241062

    City of Dallas permitCommercial Electrical Permit
    Record
    COM-ELC-26-000208
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro

Sources: City of Dallas

Questions about 10851 Miller Rd

What is being built at 10851 Miller Rd in Dallas?

Dallas permits indicate warehouse shell construction and spec office space. June 2026 permits cover shell-building plumbing and warehouse mechanical systems.

Is a warehouse being built at 10851 Miller Rd?

Permits describe ground-up shell-building work and mechanical systems for warehouse buildings 1A, 1B and 2. A plumbing permit for ground-up shell work was filed June 5, 2026.

Is there office space planned at 10851 Miller Rd?

Permits filed October 22 and November 13, 2026 describe first-time finish-outs for spec office space. The November permit is COM-NEW-26-000350.

When were permits filed for 10851 Miller Rd?

The records span January 15 through November 13, 2026. Recent permits include warehouse mechanical work in June and office finish-outs in October and November.

What businesses are moving to 10851 Miller Rd?

The records describe spec office space and warehouse buildings but do not name tenants or businesses moving to the address.

How much will the project at 10851 Miller Rd cost?

The available records do not provide a project-wide cost estimate or reported permit valuation.

Also being built nearby

All of 75238