10865 Miller Rd
Dallas, TX 75238
Warehouse shell and Building 2 office work at 10865 Miller Rd
Dallas permit records indicate a ground-up shell building with sewer, water and gas work at 10865 Miller Rd. Later filings cover warehouse equipment, a first-time finish-out of a shell warehouse and an interior spec office in Building 2. The first listed permit was filed March 31, 2026, and the latest was filed October 27, 2026.
Summarized from City of Dallas records · updated Oct 27, 2026
- Projects
- 7
- 7 filings
- Latest filing
- Oct 27, 2026
- since Mar 31, 2026
- Largest scope
- —
- Listed value
- —
Permit & project history
7 projectsProvision & installation of the following:• warehouse (building. 2):• (6) gas fired unit heater(s) with spark ignition, power vent and standard thermostat, 300 mbh input each, 120/1/60• (5) roof mounted propeller exhaust fan(s), complete with high temperature rating, 35,000 cfm, standard insulated flat factory curb, magnetic damper latches, and nema-3 service disconnect, 7.5 hp 460/3/60• (1) unrated roof mounted propeller exhaust fan(s), complete with 15,000 cfm, standard insulated flat factory curb, butterfly backdraft damper, magnetic damper latches and nema-3 service disconnect, 3 hp 460/3/60• (5) wall mounted adjustable louver(s) (96” x 120” x 6”) of extruded aluminum construction complete with mill finish, motor operator(s) and birdscreen, 120/1/60• pump room:• (1) 5kw electric unit heater with mounting bracket and integral thermostat, 460/3/60• (1) roof mounted exhaust fan with fractional hp motor, nema-1 service disconnect, roof curb, and gravity backdraft damper• (1) rectangular duct drop with fire damper (if required at the lid of the pump room)• (1) wall mounted adjustable louver (24” x 24” x 6”) of extruded aluminum construction complete with mill finish, motor operator and birdscreen, 120/1/60• note: this pump room design is based on an electric fire pump.• provision (only), of the following:• (1) line voltage thermostat for pump room ventilation system – installed by electrician
Provision & installation of the following:• warehouse (building. 2):• (6) gas fired unit heater(s) with spark ignition, power vent and standard thermostat, 300 mbh input each, 120/1/60• (5) roof mounted propeller exhaust fan(s), complete with high temperature rating, 35,000 cfm, standard insulated flat factory curb, magnetic damper latches, and nema-3 service disconnect, 7.5 hp 460/3/60• (1) unrated roof mounted propeller exhaust fan(s), complete with 15,000 cfm, standard insulated flat factory curb, butterfly backdraft damper, magnetic damper latches and nema-3 service disconnect, 3 hp 460/3/60• (5) wall mounted adjustable louver(s) (96” x 120” x 6”) of extruded aluminum construction complete with mill finish, motor operator(s) and birdscreen, 120/1/60• pump room:• (1) 5kw electric unit heater with mounting bracket and integral thermostat, 460/3/60• (1) roof mounted exhaust fan with fractional hp motor, nema-1 service disconnect, roof curb, and gravity backdraft damper• (1) rectangular duct drop with fire damper (if required at the lid of the pump room)• (1) wall mounted adjustable louver (24” x 24” x 6”) of extruded aluminum construction complete with mill finish, motor operator and birdscreen, 120/1/60• note: this pump room design is based on an electric fire pump.• provision (only), of the following:• (1) line voltage thermostat for pump room ventilation system – installed by electrician
City of Dallas permitCommercial Mechanical Permit222 lf of 6" pvc sewer laterals from public ssmh to building. laterals "q" and "p" from the public easement line towards the building
222 lf of 6" pvc sewer laterals from public ssmh to building. laterals "q" and "p" from the public easement line towards the building
City of Dallas permitCommercial Plumbing Permit
Sources: City of Dallas
Questions about 10865 Miller Rd
What is being built at 10865 Miller Rd in Dallas?
Dallas permit records describe ground-up shell building utility work, warehouse work and an interior spec office in Building 2. The filings do not identify a tenant.
Is a new warehouse being built at 10865 Miller Rd?
A March 31, 2026, plumbing permit describes ground-up shell building sewer, water and gas work. A July 30 permit describes a first-time finish-out of a shell warehouse.
What is being added to Building 2 at 10865 Miller Rd?
A permit filed October 12, 2026, describes an interior spec office and sewer, water and gas work. A June 23 mechanical permit lists heaters, exhaust fans and ventilation equipment for the warehouse and pump room.
When were permits filed for work at 10865 Miller Rd?
The listed filings run from March 31, 2026, through October 27, 2026. The latest record, COM-NEW-26-000354, is for an electrical upgrade for suite 200.
Is a business or tenant named for 10865 Miller Rd?
The provided permit records do not identify an occupant or tenant. They describe warehouse, office, utility and electrical work.
What does the warehouse work at 10865 Miller Rd include?
A June 23, 2026, mechanical permit lists gas-fired unit heaters, exhaust fans and wall louvers for the warehouse, along with equipment for a pump room. A July 30 permit describes a first-time finish-out of a shell warehouse.
Also being built nearby
All of 75238- 10855 Miller RdNov 16, 2026Building 1b spec - sewer/water/gas for interior spec office · 16 m away
- 10851 Miller RdNov 13, 2026Qteam inhouse first time finish out for spec office · 22 m away
- 10851 Miller Road · Idil Miller 365, LPNov 4, 2026Idi miller road - b1a - spec suite — new construction — new construction of a first generation spec office suite and remote unisex restroom within a existing warehouse. 3,742 sq ft · 22 m away
- 10741 Miller RdSep 17, 2026Replace a backflow/rpz device · 199 m away
- 10705 Plano RdJul 20, 2026No work · 277 m away
- 10717 Plano RdNov 6, 2026Office show room warehouse · 282 m away
- 10723 Plano RdJan 13, 2026Utility release · 285 m away
- 10710 Sanden DrOct 24, 2025Replace a 1-1/2" rpz inside “ · 356 m away
- 10755 Sanden DrJul 17, 2025Panel upgrade · 374 m away
- 10665 Sanden DrDec 31, 2020Interior remodel only · 375 m away
- 10474 Plano RdDec 12, 2025Gas test · 374 m away
- 10466 Plano RdJun 1, 2026This is for the electrical no work to get the power turned back on · 393 m away