1455 Round Table Dr

Dallas, TX 75247 · Prime Dc 3mw Buildout, Prime Data Center

Prime Data Centers buildout planned at 1455 Round Table Dr

Permits indicate a 34,438-square-foot partial tenant buildout for a data center at 1455 Round Table Dr, including a data hall, administrative spaces and infrastructure for four generators. Dallas permit filings began December 1, 2025, with additional electrical, plumbing and mechanical permits filed through August 10, 2026.

Summarized from City of Dallas, Texas Department of Licensing and Regulation records · updated Aug 10, 2026

Projects
24
24 filings
Latest filing
Aug 10, 2026
since Jan 19, 2024
Largest scope
96,796 sf
Estimated cost
$48M
state registration

Permit & project history

24 projects
  1. 2nd floor data center fit out for prime data centers

    2nd floor data center fit out for prime data centers

    City of Dallas permitCommercial Electrical Permit
    Record
    COM-ELC-26-003732
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  2. New chillers and associated piping, new vrf systems and associated duct

    New chillers and associated piping, new vrf systems and associated duct

    City of Dallas permitCommercial Mechanical Permit
    Record
    COM-MEC-26-001985
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  3. Commercial plumbing rough-in and finish out. building core and shell already in place. scope includes new sanitary waste and vent rough-in, domestic hot & cold water rough-in, water heaters, booster pump, and plumbing fixtures. no storm piping included

    Commercial plumbing rough-in and finish out. building core and shell already in place. scope includes new sanitary waste and vent rough-in, domestic hot & cold water rough-in, water heaters, booster pump, and plumbing fixtures. no storm piping included

    City of Dallas permitCommercial Plumbing Permit
    Record
    COM-PLM-26-002996
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  4. Commercial plumbing rough-in and finish out. building core and shell already in place. scope includes new sanitary waste and vent rough-in, domestic hot & cold water rough-in, water heaters, booster pump, and plumbing fixtures. no storm piping included

    Commercial plumbing rough-in and finish out. building core and shell already in place. scope includes new sanitary waste and vent rough-in, domestic hot & cold water rough-in, water heaters, booster pump, and plumbing fixtures. no storm piping included

    City of Dallas permitCommercial Plumbing Permit
    Record
    COM-PLM-26-002995
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  5. New chillers and associated piping, new vrf systems and associated duct

    New chillers and associated piping, new vrf systems and associated duct

    City of Dallas permitCommercial Mechanical Permit
    Record
    COM-MEC-26-001984
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  6. Filing

    City of Dallas permitPhase - Alteration Addition
    Record
    COM-PH-ALT-ADD-26-000403
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  7. Filing

    City of Dallas permitPhase - Alteration Addition
    Record
    COM-PH-ALT-ADD-26-000402
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  8. Mcr 1455 roundtable dr. ddw01-02 prime data center dfw01-02 34,438 sq ft partial tenant improvement buildout including construction of administrative spaces, data hall and infrastructure buildout on levels 1, 3, and roof and site enhancements for four generators and associated switchgea

    Mcr 1455 roundtable dr. ddw01-02 prime data center dfw01-02 34,438 sq ft partial tenant improvement buildout including construction of administrative spaces, data hall and infrastructure buildout on levels 1, 3, and roof and site enhancements for four generators and associated switchgea

    City of Dallas permitPhase - Alteration Addition
    Record
    COM-PH-ALT-ADD-26-000401
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  9. Mcr 1455 roundtable dr. ddw01-02 prime data center dfw01-02 34,438 sq ft partial tenant improvement buildout including construction of administrative spaces, data hall and infrastructure buildout on levels 1, 3, and roof and site enhancements for four generators and associated switchgea

    Mcr 1455 roundtable dr. ddw01-02 prime data center dfw01-02 34,438 sq ft partial tenant improvement buildout including construction of administrative spaces, data hall and infrastructure buildout on levels 1, 3, and roof and site enhancements for four generators and associated switchgea

    City of Dallas permitPhase - Alteration Addition
    Record
    COM-PH-ALT-ADD-26-000400
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  10. Commercial plumbing rough-in and finishout. building core and shell already in place. scope includes new sanitary waste and vent rough-in, domestic hot & cold water rough-in, water heaters, booster pump, and plumbing fixtures. no storm piping included

    Commercial plumbing rough-in and finishout. building core and shell already in place. scope includes new sanitary waste and vent rough-in, domestic hot & cold water rough-in, water heaters, booster pump, and plumbing fixtures. no storm piping included

    City of Dallas permitCommercial Plumbing Permit
    Record
    COM-PLM-26-002443
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  11. New chillers and associated piping, new vrf systems and associated duct

    New chillers and associated piping, new vrf systems and associated duct

    City of Dallas permitCommercial Mechanical Permit
    Record
    COM-MEC-26-001567
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  12. Filing

    City of Dallas permitPhase - Alteration Addition
    Record
    COM-PH-ALT-ADD-26-000281
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  13. Filing

    City of Dallas permitPhase - Alteration Addition
    Record
    COM-PH-ALT-ADD-26-000282
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  14. All scope of work as detailed on the plans up to bulletin 2 dated 06-05-2026; also includes the generator yard

    All scope of work as detailed on the plans up to bulletin 2 dated 06-05-2026; also includes the generator yard

    City of Dallas permitPhase - Alteration Addition
    Record
    COM-PH-ALT-ADD-26-000276
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  15. Includes all scope of work for floor 2 as detailed on the plans up to bulletin 2 dated 06-05-2026. this phase also includes the water treatment room on the 3rd floor (see plans) and rooftop work

    Includes all scope of work for floor 2 as detailed on the plans up to bulletin 2 dated 06-05-2026. this phase also includes the water treatment room on the 3rd floor (see plans) and rooftop work

    City of Dallas permitPhase - Alteration Addition
    Record
    COM-PH-ALT-ADD-26-000277
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  16. Electrical service for the 1455 prime data center is provided from the local utility medium-voltage (mv) distribution pole. the utility mv feeder is routed underground via duct banks to the exterior mv sw then under the building and terminates at the interior medium-voltage switchgear located in a dedicated electrical room. all mv infrastructure is installed in accordance with utility requirements, nec, ieee standards, and local authority regulations, including grounding and bonding systems.the mv switchgear provides service entrance protection, metering, isolation, and distribution to downstream mv-to-lv transformers. protective relays are fully coordinated with utility and downstream devices to ensure selective coordination and system reliability. the mv switchgear distributes power to multiple transformers sized for data hall it loads, mechanical systems, office fit-out, and future capacity.medium-voltage power is stepped down through transformers to low-voltage distribution, typically 480/277v, and routed to main distribution boards, mechanical switchboards, and emergency power equipment located in interior electrical rooms. the low-voltage distribution system supplies all critical and non-critical facility loads and includes metering, surge protection, and expansion provisions.dedicated feeders from the low-voltage distribution system supply power distribution units (pdus) serving the 3rd-floor data hall. feeders are routed through protected vertical risers and electrical pathways designed for redundancy and physical separation. pdus distribute power to it equipment at utilization voltages and are arranged to support dual power paths in accordance with data center reliability requirements.electrical power is also distributed to all mechanical equipment, including chillers, pumps, crah/crac units, air handling equipment, cooling towers, and associated controls. mechanical loads are supplied from dedicated mechanical switchboards and motor control centers, with critical cooling systems connected to emergency and generator-backed power.the office and support areas are supplied from normal power distribution panels serving lighting, receptacles, and office equipment. life safety systems, emergency lighting, and required egress circuits are coordinated with both normal and emergency power systems.the facility includes on-site generators supplying emergency power through generator switchgear and automatic transfer switches (ats). generator feeders support critical it loads, pdus, essential mechanical equipment, and life safety systems to maintain continuous operation during utility outages.a comprehensive grounding and bonding system is provided throughout the facility, including mv and lv equipment grounding, data hall bonding grids, generator grounding, and utility grounding interfaces. the overall electrical system is designed to provide a reliable, scalable, and maintainable infrastructure supporting mission-critical data center operations

    Electrical service for the 1455 prime data center is provided from the local utility medium-voltage (mv) distribution pole. the utility mv feeder is routed underground via duct banks to the exterior mv sw then under the building and terminates at the interior medium-voltage switchgear located in a dedicated electrical room. all mv infrastructure is installed in accordance with utility requirements, nec, ieee standards, and local authority regulations, including grounding and bonding systems.the mv switchgear provides service entrance protection, metering, isolation, and distribution to downstream mv-to-lv transformers. protective relays are fully coordinated with utility and downstream devices to ensure selective coordination and system reliability. the mv switchgear distributes power to multiple transformers sized for data hall it loads, mechanical systems, office fit-out, and future capacity.medium-voltage power is stepped down through transformers to low-voltage distribution, typically 480/277v, and routed to main distribution boards, mechanical switchboards, and emergency power equipment located in interior electrical rooms. the low-voltage distribution system supplies all critical and non-critical facility loads and includes metering, surge protection, and expansion provisions.dedicated feeders from the low-voltage distribution system supply power distribution units (pdus) serving the 3rd-floor data hall. feeders are routed through protected vertical risers and electrical pathways designed for redundancy and physical separation. pdus distribute power to it equipment at utilization voltages and are arranged to support dual power paths in accordance with data center reliability requirements.electrical power is also distributed to all mechanical equipment, including chillers, pumps, crah/crac units, air handling equipment, cooling towers, and associated controls. mechanical loads are supplied from dedicated mechanical switchboards and motor control centers, with critical cooling systems connected to emergency and generator-backed power.the office and support areas are supplied from normal power distribution panels serving lighting, receptacles, and office equipment. life safety systems, emergency lighting, and required egress circuits are coordinated with both normal and emergency power systems.the facility includes on-site generators supplying emergency power through generator switchgear and automatic transfer switches (ats). generator feeders support critical it loads, pdus, essential mechanical equipment, and life safety systems to maintain continuous operation during utility outages.a comprehensive grounding and bonding system is provided throughout the facility, including mv and lv equipment grounding, data hall bonding grids, generator grounding, and utility grounding interfaces. the overall electrical system is designed to provide a reliable, scalable, and maintainable infrastructure supporting mission-critical data center operations

    City of Dallas permitCommercial Electrical Permit
    Record
    COM-ELC-26-002104
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  17. Filing

    City of Dallas permitPhase - Alteration Addition
    Record
    COM-PH-ALT-ADD-25-000387
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  18. Mcr 1455 roundtable dr. ddw01-02 prime data center dfw01-02 34,438 sq ft partial tenant improvement buildout including construction of administrative spaces, data hall and infrastructure buildout on levels 1, 3, and roof and site enhancements for four generators and associated switchgea

    Mcr 1455 roundtable dr. ddw01-02 prime data center dfw01-02 34,438 sq ft partial tenant improvement buildout including construction of administrative spaces, data hall and infrastructure buildout on levels 1, 3, and roof and site enhancements for four generators and associated switchgea

    City of Dallas permitCommercial Alteration Addition Permit
    Record
    COM-ALT-ADD-25-001962
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  19. Filing

    City of Dallas permitPhase - Alteration Addition
    Record
    COM-PH-ALT-ADD-25-000388
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  20. Prime DC 3MW Buildout

    34,438 sq ft partial tenant improvement buildout including construction of administrative spaces, data hall and infrastructure buildout on levels 1, 3, and roof and site enhancements for four generators and associated switchgea — prime data center dfw01-02

    TDLR project registrationRenovation/AlterationProject Registered34,438 sq ft$48M est.
    Tenant / owner
    Prime Dc 3mw Buildout
    Design firm
    Pro
    Contact
    Pro
  21. Add 22' bi-folding auto gate with knox keyswitch and knox padlock with 911 pins along with 80' of 8' tall iron curved oicket security fence (to match existing)

    Add 22' bi-folding auto gate with knox keyswitch and knox padlock with 911 pins along with 80' of 8' tall iron curved oicket security fence (to match existing)

    City of Dallas permitCommercial Accessory Structure Permit
    Record
    COM-ACC-25-000159
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  22. New build of a core+shell

    New build of a core+shell

    City of Dallas permitCommercial Mechanical Permit
    Record
    2402201133_187337971-004_ME_1
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  23. New build of a core+shell

    New build of a core+shell

    City of Dallas permitCommercial Mechanical Permit$14M
    Record
    2402201132_187337971-003_ME_1
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  24. PRIME DATA CENTER

    Three-story 96,796 sq ft data center building constructed in phases. the initial phase will consist of an unoccupied core and shell with site enhancements. the core package and shell will be designed to support the full build out. — dfw01-02

    TDLR project registrationNew ConstructionInspection Complete96,796 sq ft$22M est.
    Tenant / owner
    Prime Data Center
    Design firm
    Pro
    Contact
    Pro

Sources: City of Dallas · Texas Department of Licensing and Regulation

Questions about 1455 Round Table Dr

What is being built at 1455 Round Table Dr in Dallas?

Permit records describe a partial tenant buildout for a Prime Data Centers data center, including a data hall, administrative spaces and infrastructure. The building’s core and shell were already in place.

How large is the data center buildout at 1455 Round Table Dr?

The permit description lists a 34,438-square-foot partial tenant improvement buildout.

When were permits filed for the 1455 Round Table Dr project?

The first filing in the records is dated December 1, 2025. A commercial electrical permit for a second-floor data center fit-out was filed August 10, 2026.

What work is included in the data center buildout?

Permit descriptions list administrative spaces, a data hall, infrastructure on levels 1 and 3 and the roof, and site enhancements for four generators. Later permits also cover electrical, plumbing and mechanical work.

What is the estimated cost of the 1455 Round Table Dr project?

The Texas Department of Licensing and Regulation lists an estimated project cost of $47.5 million. This is the applicant’s estimate for the project.

Is a new building being constructed at 1455 Round Table Dr?

The records describe a tenant buildout, not construction of a new building. A plumbing permit says the building core and shell were already in place.