4506 Best Way
Austin, TX 78725
Permit covers replacement of a six-meter bank at 4506 Best Way
An electrical permit filed October 3, 2025, covers replacing a modular meter bank serving six meters at 4506 Best Way. The permit describes a 600-amp main disconnect and says the home at 4506 will need new feeders under a separate permit. The listed record is marked final.
Summarized from City of Austin records · updated Oct 3, 2025
- Projects
- 1
- 1 filings
- Latest filing
- Oct 3, 2025
- since Oct 3, 2025
- Largest scope
- —
- Listed value
- —
Where this project stands
FinaledReplace modular meter bank with new meter bank - modular meter bank has 6 meters for it. revised 9/30/25 sm - 600 amp main disconnect serving mme of (6) meters with (6) 100 amp disconnects. ec states ae required a 600 amp disconnect before the meters. only 1 set of 350 al existing underground for the service? units 4500 4502 4504 and 4510 to be energized. unit 4506 will need new feeders from the 100 amp breaker to the house. unit 4508 will need a new neutral pulled from the meter bank to the house. will be different permits as the hoa is not responsible for feeders. all homes are occupied
- AppliedSep 29, 2025
- IssuedOct 3, 2025
- WorkOct '25 – Oct '25
- Final inspectionJul 13, 2026
Passed final inspection Jul 13, 2026.
1 contact on this project · 1 phone number
Permit & project history
1 projectReplace modular meter bank with new meter bank - modular meter bank has 6 meters for it. revised 9/30/25 sm - 600 amp main disconnect serving mme of (6) meters with (6) 100 amp disconnects. ec states ae required a 600 amp disconnect before the meters. only 1 set of 350 al existing underground for the service? units 4500 4502 4504 and 4510 to be energized. unit 4506 will need new feeders from the 100 amp breaker to the house. unit 4508 will need a new neutral pulled from the meter bank to the house. will be different permits as the hoa is not responsible for feeders. all homes are occupied
Replace modular meter bank with new meter bank - modular meter bank has 6 meters for it. revised 9/30/25 sm - 600 amp main disconnect serving mme of (6) meters with (6) 100 amp disconnects. ec states ae required a 600 amp disconnect before the meters. only 1 set of 350 al existing underground for the service? units 4500 4502 4504 and 4510 to be energized. unit 4506 will need new feeders from the 100 amp breaker to the house. unit 4508 will need a new neutral pulled from the meter bank to the house. will be different permits as the hoa is not responsible for feeders. all homes are occupied
City of Austin permitElectrical PermitFinal- Record
- 2025-123380 EP
- Tenant / owner
- Pro
- Contractor
- Pro
- Contact
- Pro
Sources: City of Austin
Questions about 4506 Best Way
What is being built at 4506 Best Way?
An Austin electrical permit covers replacement of a modular meter bank serving six meters. It does not describe a new building.
What work does permit 2025-123380 EP cover?
The October 3, 2025, permit covers a new meter bank, a 600-amp main disconnect and six 100-amp disconnects.
When was the electrical permit filed for 4506 Best Way?
The City of Austin permit was filed October 3, 2025, and is marked final.
How many meters does the new meter bank serve?
The permit describes a modular bank with six meters.
Does the meter-bank permit include new feeders to 4506 Best Way?
The permit says 4506 will need new feeders from the 100-amp breaker to the home. It notes that this work will require a separate permit.
Also being built nearby
All of 78725- 4521 Credo LnOct 15, 2026Etj ec is replacing the existing mcb in an existing meter pack with a larger breaker. inspection stops at the mcb · 86 m away
- 4512 Credo LnApr 25, 2025Install new 6.090 dc kw rooftop solar system for existing residential only · 89 m away
- 4517 Secure LnJan 16, 2026To install an ev charger at the same time as a solar system ev charger will be fed from solar · 137 m away
- 4524 Felicity LnJul 1, 2026197amp replacement. no meter work being done. austin electric is the provider · 187 m away
- 4626 Best WayMar 5, 2026Replacement of an existing water heater remove and replace water heater - 40 gal electric · 278 m away
- 4600 Dunlap RdFeb 2, 2010Chaparral crossing · 280 m away
- 4610 Kind WayFeb 20, 2025Disconnect/reconnect power to tie in pv component and upgrading msp to 225 amps. 100 main breaker. upgrading revenue meter to 200 amps · 311 m away
- 4501 Dunlap RdMar 11, 2013Txi hornsby bend east · 313 m away
- 4622 Kind WayFeb 23, 2026Replacement of an existing water heater water heater change out 4622 kind way austin tx 78725 · 351 m away
- 4617 Esper LnApr 8, 2024Replacement of an existing water heater · 358 m away
- 910-1/2 Dunlap RdMar 11, 2013Txi hornsby bend west site plan revision · 381 m away