Electrical work for the existing Krieg Field pond pump
A new electrical connection is being installed for the existing water quality control pond pump at Krieg Field. The City of Austin permit, filed June 22, 2026, covers about 345 feet of conduit and a transformer. A separate mechanical permit filed in 2024 records replacement of the existing heating and air-conditioning system.
Summarized from City of Austin records · updated Jun 22, 2026
- Projects
- 3
- 3 filings
- Latest filing
- Jun 22, 2026
- since May 24, 2024
- Largest scope
- —
- Listed value
- —
Where this project stands
FinaledElectrical connection to existing water quality control pond pump at krieg field (city of austin parks and recreation). install approximately 345 linear feet of electrical conduit from an existing panel to the existing pump electrical connection point. install one 15-amp 480-volt 1-phase circuit from existing 480-volt panel to a location near the pump controller. at the pump controller location install one rack-mounted 7kva 480-120/240-volt transformer with service disconnects for line and load connections. terminate new low-voltage circuit to the pump controller. underground feeder routed in 2 schedule 80 pvc from the 480-volt panel to the transformer with two in-ground quazite boxes with lids. conductor size increased based on limiting voltage drop due to length. pump controller and alarm system provided by others and existing. trenching provided by city of austin parks and recreation
- AppliedJun 10, 2026
- IssuedJun 22, 2026
- WorkJun '26 – Oct '26
- Final inspectionOct 20, 2026
Passed final inspection Oct 20, 2026.
1 contact on this project · 1 phone number
Permit & project history
3 projectsElectrical connection to existing water quality control pond pump at krieg field (city of austin parks and recreation). install approximately 345 linear feet of electrical conduit from an existing panel to the existing pump electrical connection point. install one 15-amp 480-volt 1-phase circuit from existing 480-volt panel to a location near the pump controller. at the pump controller location install one rack-mounted 7kva 480-120/240-volt transformer with service disconnects for line and load connections. terminate new low-voltage circuit to the pump controller. underground feeder routed in 2 schedule 80 pvc from the 480-volt panel to the transformer with two in-ground quazite boxes with lids. conductor size increased based on limiting voltage drop due to length. pump controller and alarm system provided by others and existing. trenching provided by city of austin parks and recreation
Electrical connection to existing water quality control pond pump at krieg field (city of austin parks and recreation). install approximately 345 linear feet of electrical conduit from an existing panel to the existing pump electrical connection point. install one 15-amp 480-volt 1-phase circuit from existing 480-volt panel to a location near the pump controller. at the pump controller location install one rack-mounted 7kva 480-120/240-volt transformer with service disconnects for line and load connections. terminate new low-voltage circuit to the pump controller. underground feeder routed in 2 schedule 80 pvc from the 480-volt panel to the transformer with two in-ground quazite boxes with lids. conductor size increased based on limiting voltage drop due to length. pump controller and alarm system provided by others and existing. trenching provided by city of austin parks and recreation
City of Austin permitElectrical PermitFinal- Record
- 2026-074050 EP
- Tenant / owner
- Pro
- Contractor
- Pro
- Contact
- Pro
Replacement of complete existing central heat and air system with or without duct work
Replacement of complete existing central heat and air system with or without duct work
City of Austin permitMechanical PermitFinal- Record
- 2024-125395 MP
- Tenant / owner
- Pro
- Contractor
- Pro
- Contact
- Pro
Replacement of complete existing central heat and air system with or without duct work at austin public safety wellness center
Replacement of complete existing central heat and air system with or without duct work at austin public safety wellness center
City of Austin permitMechanical PermitFinal- Record
- 2024-064645 MP
- Tenant / owner
- Pro
- Contractor
- Pro
- Contact
- Pro
Sources: City of Austin
Questions about 517 S Pleasant Valley Rd
What is being built at 517 S Pleasant Valley Rd?
A City of Austin permit covers electrical work for the existing water quality control pond pump at Krieg Field, including conduit, a circuit and a transformer. It does not describe a new building.
What is the electrical work at Krieg Field for?
Permit 2026-074050 EP covers a new electrical connection to the existing pond pump and pump controller. The permit was filed June 22, 2026.
When was the pond pump electrical permit filed?
The City of Austin filed permit 2026-074050 EP on June 22, 2026. Its status is listed as final.
How much conduit is planned at 517 S Pleasant Valley Rd?
The permit describes approximately 345 linear feet of electrical conduit running from an existing panel to the pump connection area.
Was HVAC work permitted at 517 S Pleasant Valley Rd?
Yes. City of Austin mechanical permit 2024-125395 MP, filed September 18, 2024, covers replacement of the existing central heating and air-conditioning system.
Also being built nearby
All of 78741- 517 South Pleasant Valley Road · City Of AustinFeb 17, 2024Afd wellness center parking improvements — renovation/alteration — rehabilitate the existing parking lot and drive isles by replacement of curb and gutter, driveway/drive isles, sidewalk and ramps, geometrical enhancements (tree protection and parking reconfiguration)
- 1109 S Pleasant Valley RdAug 26, 2026Replacement of complete existing central heat and air system with or without duct work · 216 m away
- 517 Pleasant Valley RdJul 25, 2024+fs driveway replacements parent - afd wellness center · 268 m away
- 2525 South Lakeshore BlvdMay 8, 2024Replacement of complete existing central heat and air system with or without duct work - 1001.356 · 330 m away
- 1109 Pleasant Valley RdFeb 4, 2009Jefferson commons at the ballpark, amended plat of lot 2, block a — jefferson commons at the ballpark, block a; amended plat of lot 2, a resub of lot 1 pleasant valley sportsplex & lot 1 grandslam addition · 377 m away
- 425 Pleasant Valley RdJul 8, 2026Pard - krieg playing fields - multipurpose field artificial turf conversion · 396 m away
- 2323 South Lakeshore BlvdOct 29, 2008Kassuba beach phase three demolition site plan · 470 m away
- 2225 South Lakeshore BlvdJan 21, 2022Waterfront phase 1 & 2 · 497 m away
- 2401 South Lakeshore BlvdJun 17, 2024Replace meter base to existing commerical (unit 5103) only · 500 m away
- 203-1/2 Pleasant Valley RdJan 6, 2026Longhorn dam multimodal improvement · 526 m away
- 4600 Elmont DrJul 17, 2026Replacement of complete existing central heat and air system with or without duct work replacement of hvac system without duct work for unit telecomm room in leasing building · 545 m away
- 1225 Pleasant Valley RdNov 8, 201997 acres east riverside and pleasant valley · 570 m away