groundranger
Active · latest filing Sep 2026Residential

8300 Shenandoah Dr

Austin, TX 78753

Permits cover HVAC replacement and range-hood wiring

Permits indicate work at this Austin home includes replacing the existing central heating and air system, permitted September 22, 2026, and installing a new electrical circuit for a kitchen range hood, permitted April 5, 2026. The records do not describe construction of a new building.

Summarized from City of Austin records · updated Sep 22, 2026

Projects
3
3 filings
Latest filing
Sep 22, 2026
since Apr 5, 2026
Largest scope
—
Listed value
—

Where this project stands

Finaled

Replacement of complete existing central heat and air system with or without duct work replacement of hvac system through austin energys weatherization assistance program

  1. AppliedSep 16, 2026
  2. IssuedSep 22, 2026
  3. WorkSep '26 – Oct '26
  4. Final inspectionOct 15, 2026

Passed final inspection Oct 15, 2026.

1 contact on this project · 1 phone number

Permit & project history

3 projects
  1. Replacement of complete existing central heat and air system with or without duct work replacement of hvac system through austin energys weatherization assistance program

    Replacement of complete existing central heat and air system with or without duct work replacement of hvac system through austin energys weatherization assistance program

    City of Austin permitMechanical PermitFinal
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  2. Project scope provide one new dedicated afci/gfci protected 20a 120v branch circuit from the main panel on the exterior wall of the house to a new kitchen range hood. no meter work being performed. installation details install a vertical 1-inch steel emt raceway exiting the main electrical panel from a 1-inch lr conduit body (located below all energized parts) on the homes exterior brick wall. transition raceway to horizontal orientation for building penetration using a 1 lb. penetrate into the accessible attic with 1 emt terminating into a 4-11/16 steel junction box with a blank cover. install #10-2 uf-b cable (1 hot 1 neutral 1 egc) (sunlight resistant/wet location rated) from the range hood to the steel junction box. cable will be routed along ceiling rafters; any portion below 7 will be protected by guard strips per nec 320.23. the #10-2 uf-b will be sleeved continuously from the 4-11/16 junction box through the lb down the vertical emt and through the lr terminating directly into the main panel. this avoids all splices providing a continuous run from the ocpd to the appliance. code compliance notes: 10 awg conductors are specd. for this 20a circuit to account for ambient temperature correction in the unconditioned attic and sun-exposed exterior raceway. the emt will be sealed with duct seal at the attic box and panel entry to prevent moisture migration and condensation per nec 300.7. all cables and raceways will be supported/secured per nec. all exterior fittings/hardware will be ul-listed rain-tight compression type. all cables and raceways will be supported and secured per nec requirements. an insulated throat fitting or plastic bushing will be used at all emt entry points to protect the cable jacket from abrasion. all wire terminations will be torqued to the manufacturer specifications per 110.14(d)

    Project scope provide one new dedicated afci/gfci protected 20a 120v branch circuit from the main panel on the exterior wall of the house to a new kitchen range hood. no meter work being performed. installation details install a vertical 1-inch steel emt raceway exiting the main electrical panel from a 1-inch lr conduit body (located below all energized parts) on the homes exterior brick wall. transition raceway to horizontal orientation for building penetration using a 1 lb. penetrate into the accessible attic with 1 emt terminating into a 4-11/16 steel junction box with a blank cover. install #10-2 uf-b cable (1 hot 1 neutral 1 egc) (sunlight resistant/wet location rated) from the range hood to the steel junction box. cable will be routed along ceiling rafters; any portion below 7 will be protected by guard strips per nec 320.23. the #10-2 uf-b will be sleeved continuously from the 4-11/16 junction box through the lb down the vertical emt and through the lr terminating directly into the main panel. this avoids all splices providing a continuous run from the ocpd to the appliance. code compliance notes: 10 awg conductors are specd. for this 20a circuit to account for ambient temperature correction in the unconditioned attic and sun-exposed exterior raceway. the emt will be sealed with duct seal at the attic box and panel entry to prevent moisture migration and condensation per nec 300.7. all cables and raceways will be supported/secured per nec. all exterior fittings/hardware will be ul-listed rain-tight compression type. all cables and raceways will be supported and secured per nec requirements. an insulated throat fitting or plastic bushing will be used at all emt entry points to protect the cable jacket from abrasion. all wire terminations will be torqued to the manufacturer specifications per 110.14(d)

    City of Austin permitElectrical PermitFinal
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  3. Rebuild 200a oh main service panel

    Rebuild 200a oh main service panel

    City of Austin permitElectrical PermitFinal
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro

Sources: City of Austin

Questions about 8300 Shenandoah Dr

What is being built at 8300 Shenandoah Dr?

The permits describe home improvements: replacement of the existing central heating and air system and installation of a dedicated electrical circuit for a kitchen range hood. They do not describe a new building.

Is a restaurant opening at 8300 Shenandoah Dr?

The available permits describe residential HVAC and electrical work, not a restaurant opening.

What HVAC work is permitted at this address?

A permit filed September 22, 2026, covers replacement of the complete existing central heat and air system, with or without ductwork replacement. The permit number is 2026-121885 MP.

What electrical work is permitted at 8300 Shenandoah Dr?

A permit filed April 5, 2026, covers a new dedicated 20-amp circuit for a kitchen range hood. The permit number is 2026-037859 EP.

When were permits filed for 8300 Shenandoah Dr?

The records show filings on April 5, 2026, for the range-hood circuit and September 22, 2026, for the HVAC replacement. Both permits have final status.

Also being built nearby

All of 78753

More restaurants in 78753.

Email me when a new permit is filed