1818 Corsicana St

Dallas, TX 75201 · The Bridge - Office Renovation, The Bridge - Pavilion Redesign And Construction

Permits cover generator and plumbing work at 1818 Corsicana St

City of Dallas permits indicate upgrades to the building at 1818 Corsicana St, including a gas generator and a new underground gas line. The latest related permits were filed October 9 and 12, 2026. Other 2026 permits cover plumbing work in the restrooms and laundry room, plus a grease interceptor and drainage work.

Summarized from City of Dallas, Texas Department of Licensing and Regulation records · updated Oct 12, 2026

Projects
12
12 filings
Latest filing
Oct 12, 2026
since Sep 13, 2024
Largest scope
1,600 sf
Estimated cost
$275K
state registration

Permit & project history

12 projects
  1. Add a gas generator and add a new 2 inches gas line outside biulding. underground gas line 350 liner foot

    Add a gas generator and add a new 2 inches gas line outside biulding. underground gas line 350 liner foot

    City of Dallas permitCommercial Plumbing Permit
    Record
    COM-PLM-26-003963
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  2. Generator

    Generator

    City of Dallas permitCommercial Electrical Permit
    Record
    COM-ELC-26-005058
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  3. Rough:replacing sanitary line throughout building and connecting to main line with pvc pipe/fittings. will be tunneling roughly 170ft with 2 access holes. dirt will be placed at dumpster area and in lawn inside the complex. saw cutting 20ft from access hole to main line. there will be another access (5ftx5ft) at the connection point to the main. all trenches will be covered with steel plates for security and work will comply with current dallas plumbing codes.pavilion building - top out:inside the restroom there will be 15 wall mount industrial water closets, and 6 industrial urinals replaced with new. flush valves to be reused. in the chase for the urinals the vent pipe and connection points to the fixtures will be reconfigured. the chase for the wall mount water closets will be reconfigured to add carriers and redo the vent pipe in the chase before going vertical. all vent pipe after 3ft will be existing to remain. the water lines will be reinsulated in fiberglass in both chases. rebuild all inoperable shower valves. any extras will be left with maintenance staff

    Rough:replacing sanitary line throughout building and connecting to main line with pvc pipe/fittings. will be tunneling roughly 170ft with 2 access holes. dirt will be placed at dumpster area and in lawn inside the complex. saw cutting 20ft from access hole to main line. there will be another access (5ftx5ft) at the connection point to the main. all trenches will be covered with steel plates for security and work will comply with current dallas plumbing codes.pavilion building - top out:inside the restroom there will be 15 wall mount industrial water closets, and 6 industrial urinals replaced with new. flush valves to be reused. in the chase for the urinals the vent pipe and connection points to the fixtures will be reconfigured. the chase for the wall mount water closets will be reconfigured to add carriers and redo the vent pipe in the chase before going vertical. all vent pipe after 3ft will be existing to remain. the water lines will be reinsulated in fiberglass in both chases. rebuild all inoperable shower valves. any extras will be left with maintenance staff

    City of Dallas permitCommercial Plumbing Permit
    Record
    COM-PLM-26-001582
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  4. Laundry room in welcome building plumbing in (6) new floor sinks to serve new laundry equipment as well as new plumbing as per code to serve new clothes washers and clothes dryers. the installation of the floor sinks will require a saw cut across the room to make connection to sanitary line. connections to new equipment to be made by appliance supplier and all a-star would be responsible for is providing the drain locations(floor sinks), clean outs, connections to existing sanitary, vents where possible, boiler drains, hot/cold water drops for washers, and reconfiguring dryer duct venting utilizing existing gas openings and roof penetrations for gas supply and vent roof penetrations

    Laundry room in welcome building plumbing in (6) new floor sinks to serve new laundry equipment as well as new plumbing as per code to serve new clothes washers and clothes dryers. the installation of the floor sinks will require a saw cut across the room to make connection to sanitary line. connections to new equipment to be made by appliance supplier and all a-star would be responsible for is providing the drain locations(floor sinks), clean outs, connections to existing sanitary, vents where possible, boiler drains, hot/cold water drops for washers, and reconfiguring dryer duct venting utilizing existing gas openings and roof penetrations for gas supply and vent roof penetrations

    City of Dallas permitCommercial Plumbing Permit
    Record
    COM-PLM-26-001559
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  5. Providing a 75 gal grease interceptor, sample well, hose bib, 24ft trench drain, and graded concrete pad for dumpster relocation. the hose bib will be placed along the side of the dumpster location. the trench drain will be placed on the back of the dumpster area. the grease trap/sample well will be installed in the 2 closest parking spots to (north), approximately 5ft from the main water lines that supply the building and and away from the path of the dumpster trucks path. the tie in will be on the main line located on the main drive into the parking lot

    Providing a 75 gal grease interceptor, sample well, hose bib, 24ft trench drain, and graded concrete pad for dumpster relocation. the hose bib will be placed along the side of the dumpster location. the trench drain will be placed on the back of the dumpster area. the grease trap/sample well will be installed in the 2 closest parking spots to (north), approximately 5ft from the main water lines that supply the building and and away from the path of the dumpster trucks path. the tie in will be on the main line located on the main drive into the parking lot

    City of Dallas permitCommercial Plumbing Permit
    Record
    COM-PLM-26-000999
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  6. Remove and replace existing 50 ton rtu with like make 50 ton rtu “

    Remove and replace existing 50 ton rtu with like make 50 ton rtu “

    City of Dallas permitCommercial Mechanical Permit
    Record
    COM-MEC-25-001293
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  7. Gas test

    Gas test

    City of Dallas permitCommercial Plumbing Permit
    Record
    COM-PLM-25-001678
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  8. Reconfigure group (conference) rooms into open office space. — the bridge hrc

    TDLR project registrationRenovation/AlterationProject Closed1,600 sq ft$50K est.
    Tenant / owner
    The Bridge - Office Renovation
    Design firm
    Pro
    Contact
    Pro
  9. Renovations to welcome building cell phone rm; kennel storage room; kennel outside storage room. pavilion: add new enclosed vestibule extension. — the bridge homeless recovery center

    TDLR project registrationAdditions to Existing BuildingProject Closed5,000 sq ft$275K est.
    Tenant / owner
    The Bridge - Pavilion Redesign And Construction
    Design firm
    Pro
    Contact
    Pro
  10. Remove existing roof and install new roof

    Remove existing roof and install new roof

    City of Dallas permitBuilding (BU) Commercial Alteration$437K
    Record
    2002191041
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  11. Install water heater

    Install water heater

    City of Dallas permitPlumbing (PL) Commercial Alteration$15
    Record
    2002033004
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  12. Electrical repairs

    Electrical repairs

    City of Dallas permitElectrical (EL) Commercial Alteration$5
    Record
    1908163009
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro

Sources: City of Dallas · Texas Department of Licensing and Regulation

Questions about 1818 Corsicana St

What is being built at 1818 Corsicana St in Dallas?

City permits indicate building upgrades rather than a new building, including a gas generator, plumbing work, and drainage improvements. A plumbing permit filed October 12, 2026, describes a new 2-inch gas line.

Is a generator being added at 1818 Corsicana St?

Yes. A City of Dallas electrical permit filed October 9, 2026, lists a generator, and a plumbing permit filed October 12 describes adding a gas generator and underground gas line.

What plumbing work is planned at 1818 Corsicana St?

Permits filed in 2026 cover replacement of a sanitary line, restroom fixture and vent-pipe work, and plumbing for laundry equipment. The sanitary-line permit, COM-PLM-26-001582, was filed April 28, 2026.

Is there a laundry room renovation at 1818 Corsicana St?

A City of Dallas plumbing permit filed April 24, 2026, describes plumbing for new laundry equipment in the welcome building. The work includes floor sinks, water connections, and dryer vent reconfiguration.

What is the dumpster-area work at 1818 Corsicana St?

A plumbing permit filed March 17, 2026, describes a grease interceptor, sample well, trench drain, and concrete pad for relocating a dumpster.

Is the HVAC system being replaced at 1818 Corsicana St?

A mechanical permit filed December 10, 2025, describes removing and replacing an existing 50-ton rooftop unit with a like unit.

When were permits filed for work at 1818 Corsicana St?

The records span September 11, 2025, through October 12, 2026. The most recent filings cover a generator and gas-line work.