groundranger
Recent · latest filing Jul 2026Commercial

3000 Mountain Creek Pkwy

Dallas, TX 75211

New commercial building underway at 3000 Mountain Creek Pkwy

City of Dallas permits indicate new commercial construction at 3000 Mountain Creek Pkwy, including work on multiple floors. The first filing was May 22, 2025; plumbing permits for ground-up construction were filed July 8, 2026, followed by electrical permits on July 13, 2026.

Summarized from City of Dallas records · updated Jul 13, 2026

Projects
34
34 filings
Latest filing
Jul 13, 2026
since May 22, 2025
Largest scope
—
Listed value
—

Permit & project history

34 projects
  1. Install electrical for new construction- fourth floor

    Install electrical for new construction- fourth floor

    City of Dallas permitCommercial Electrical Permit
    Record
    COM-ELC-26-003118
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  2. Installation of elecrical for new construction- third floor

    Installation of elecrical for new construction- third floor

    City of Dallas permitCommercial Electrical Permit
    Record
    COM-ELC-26-003117
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  3. Electrical installation for new construction- second floor

    Electrical installation for new construction- second floor

    City of Dallas permitCommercial Electrical Permit
    Record
    COM-ELC-26-003115
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  4. Electrical for new construction

    Electrical for new construction

    City of Dallas permitCommercial Electrical Permit
    Record
    COM-ELC-26-003113
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  5. Electrical for new construction- first floor

    Electrical for new construction- first floor

    City of Dallas permitCommercial Electrical Permit
    Record
    COM-ELC-26-003114
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  6. Gound up building, sewer, water, storm

    Gound up building, sewer, water, storm

    City of Dallas permitCommercial Plumbing Permit
    Record
    COM-PLM-26-002548
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  7. Gound up building , sewer, water, storm

    Gound up building , sewer, water, storm

    City of Dallas permitCommercial Plumbing Permit
    Record
    COM-PLM-26-002547
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  8. Gound up building sewer water and storm

    Gound up building sewer water and storm

    City of Dallas permitCommercial Plumbing Permit
    Record
    COM-PLM-26-002546
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  9. Ground up building, sewer, water storm

    Ground up building, sewer, water storm

    City of Dallas permitCommercial Plumbing Permit
    Record
    COM-PLM-26-002544
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  10. Gound up building , sewer, water, storm

    Gound up building , sewer, water, storm

    City of Dallas permitCommercial Plumbing Permit
    Record
    COM-PLM-26-002545
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  11. Scope• install 2 roof mounted chilled water vav ahu’s (140 tons)o with ddc controlso with vfd’so with disconnectso with drain pans under the chw coils • install 10 chilled water fan coil units (11 tons)o with ddc controls • install 63 vav’s with hydronic heat o with ddc controlso with zero line gyp board access doors where inaccessible o with drain pans and leak detection • install 2 roof mounted ventset exhaust fanso with vfdo with isolation rails • install 3 inline exhaust fanso with spring isolation • install 4 electric unit heatersinstall 20 fire and fire smoke dampers• install 6 fire smoke dampers not drawn • install 2 low leak motorized control dampers• install 4 roof mounted sound attenuators • all round ductwork is quoted as spiral seam per 23 31 13-2; 2.3c• install 256 grilles and diffuserso with return air boots per detail m-300;13 • install 745’ of linear bar grilleo with young regulator in inaccessible ceilings o with sight block • hot water and chilled water exp tanks (one ea) • dallas green globe standardso merv 13 final filterso factory visqueeno blue polyo cxa assist • ddc / ems integrated controls

    Scope• install 2 roof mounted chilled water vav ahu’s (140 tons)o with ddc controlso with vfd’so with disconnectso with drain pans under the chw coils • install 10 chilled water fan coil units (11 tons)o with ddc controls • install 63 vav’s with hydronic heat o with ddc controlso with zero line gyp board access doors where inaccessible o with drain pans and leak detection • install 2 roof mounted ventset exhaust fanso with vfdo with isolation rails • install 3 inline exhaust fanso with spring isolation • install 4 electric unit heatersinstall 20 fire and fire smoke dampers• install 6 fire smoke dampers not drawn • install 2 low leak motorized control dampers• install 4 roof mounted sound attenuators • all round ductwork is quoted as spiral seam per 23 31 13-2; 2.3c• install 256 grilles and diffuserso with return air boots per detail m-300;13 • install 745’ of linear bar grilleo with young regulator in inaccessible ceilings o with sight block • hot water and chilled water exp tanks (one ea) • dallas green globe standardso merv 13 final filterso factory visqueeno blue polyo cxa assist • ddc / ems integrated controls

    City of Dallas permitCommercial Mechanical Permit
    Record
    COM-MEC-26-001485
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  12. Scope• install 2 roof mounted chilled water vav ahu’s (140 tons)o with ddc controlso with vfd’so with disconnectso with drain pans under the chw coils • install 10 chilled water fan coil units (11 tons)o with ddc controls • install 63 vav’s with hydronic heat o with ddc controlso with zero line gyp board access doors where inaccessible o with drain pans and leak detection • install 2 roof mounted ventset exhaust fanso with vfdo with isolation rails • install 3 inline exhaust fanso with spring isolation • install 4 electric unit heatersinstall 20 fire and fire smoke dampers• install 6 fire smoke dampers not drawn • install 2 low leak motorized control dampers• install 4 roof mounted sound attenuators • all round ductwork is quoted as spiral seam per 23 31 13-2; 2.3c• install 256 grilles and diffuserso with return air boots per detail m-300;13 • install 745’ of linear bar grilleo with young regulator in inaccessible ceilings o with sight block • hot water and chilled water exp tanks (one ea) • dallas green globe standardso merv 13 final filterso factory visqueeno blue polyo cxa assist • ddc / ems integrated controls• 2 x major equip escalation bumps (6.5%)• 2 x minor mat escalation bumps (3%)• 2 x metal escalation bumps (10%) • 1x labor escalation bumps (3.5%) • hvac bim layer (not hosting)• 256 hours of composite clean (8hrs per week only)• badging / background checks

    Scope• install 2 roof mounted chilled water vav ahu’s (140 tons)o with ddc controlso with vfd’so with disconnectso with drain pans under the chw coils • install 10 chilled water fan coil units (11 tons)o with ddc controls • install 63 vav’s with hydronic heat o with ddc controlso with zero line gyp board access doors where inaccessible o with drain pans and leak detection • install 2 roof mounted ventset exhaust fanso with vfdo with isolation rails • install 3 inline exhaust fanso with spring isolation • install 4 electric unit heatersinstall 20 fire and fire smoke dampers• install 6 fire smoke dampers not drawn • install 2 low leak motorized control dampers• install 4 roof mounted sound attenuators • all round ductwork is quoted as spiral seam per 23 31 13-2; 2.3c• install 256 grilles and diffuserso with return air boots per detail m-300;13 • install 745’ of linear bar grilleo with young regulator in inaccessible ceilings o with sight block • hot water and chilled water exp tanks (one ea) • dallas green globe standardso merv 13 final filterso factory visqueeno blue polyo cxa assist • ddc / ems integrated controls• 2 x major equip escalation bumps (6.5%)• 2 x minor mat escalation bumps (3%)• 2 x metal escalation bumps (10%) • 1x labor escalation bumps (3.5%) • hvac bim layer (not hosting)• 256 hours of composite clean (8hrs per week only)• badging / background checks

    City of Dallas permitCommercial Mechanical Permit
    Record
    COM-MEC-26-001480
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  13. Scope• install 2 roof mounted chilled water vav ahu’s (140 tons)o with ddc controlso with vfd’so with disconnectso with drain pans under the chw coils • install 10 chilled water fan coil units (11 tons)o with ddc controls • install 63 vav’s with hydronic heat o with ddc controlso with zero line gyp board access doors where inaccessible o with drain pans and leak detection • install 2 roof mounted ventset exhaust fanso with vfdo with isolation rails • install 3 inline exhaust fanso with spring isolation • install 4 electric unit heatersinstall 20 fire and fire smoke dampers• install 6 fire smoke dampers not drawn • install 2 low leak motorized control dampers• install 4 roof mounted sound attenuators • all round ductwork is quoted as spiral seam per 23 31 13-2; 2.3c• install 256 grilles and diffuserso with return air boots per detail m-300;13 • install 745’ of linear bar grilleo with young regulator in inaccessible ceilings o with sight block • hot water and chilled water exp tanks (one ea) • dallas green globe standardso merv 13 final filterso factory visqueeno blue polyo cxa assist • ddc / ems integrated controls• 2 x major equip escalation bumps (6.5%)• 2 x minor mat escalation bumps (3%)• 2 x metal escalation bumps (10%) • 1x labor escalation bumps (3.5%) • hvac bim layer (not hosting)• 256 hours of composite clean (8hrs per week only)• badging / background checks

    Scope• install 2 roof mounted chilled water vav ahu’s (140 tons)o with ddc controlso with vfd’so with disconnectso with drain pans under the chw coils • install 10 chilled water fan coil units (11 tons)o with ddc controls • install 63 vav’s with hydronic heat o with ddc controlso with zero line gyp board access doors where inaccessible o with drain pans and leak detection • install 2 roof mounted ventset exhaust fanso with vfdo with isolation rails • install 3 inline exhaust fanso with spring isolation • install 4 electric unit heatersinstall 20 fire and fire smoke dampers• install 6 fire smoke dampers not drawn • install 2 low leak motorized control dampers• install 4 roof mounted sound attenuators • all round ductwork is quoted as spiral seam per 23 31 13-2; 2.3c• install 256 grilles and diffuserso with return air boots per detail m-300;13 • install 745’ of linear bar grilleo with young regulator in inaccessible ceilings o with sight block • hot water and chilled water exp tanks (one ea) • dallas green globe standardso merv 13 final filterso factory visqueeno blue polyo cxa assist • ddc / ems integrated controls• 2 x major equip escalation bumps (6.5%)• 2 x minor mat escalation bumps (3%)• 2 x metal escalation bumps (10%) • 1x labor escalation bumps (3.5%) • hvac bim layer (not hosting)• 256 hours of composite clean (8hrs per week only)• badging / background checks

    City of Dallas permitCommercial Mechanical Permit
    Record
    COM-MEC-26-001481
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  14. Scope• install 2 roof mounted chilled water vav ahu’s (140 tons)o with ddc controlso with vfd’so with disconnectso with drain pans under the chw coils • install 10 chilled water fan coil units (11 tons)o with ddc controls • install 63 vav’s with hydronic heat o with ddc controlso with zero line gyp board access doors where inaccessible o with drain pans and leak detection • install 2 roof mounted ventset exhaust fanso with vfdo with isolation rails • install 3 inline exhaust fanso with spring isolation • install 4 electric unit heatersinstall 20 fire and fire smoke dampers• install 6 fire smoke dampers not drawn • install 2 low leak motorized control dampers• install 4 roof mounted sound attenuators • all round ductwork is quoted as spiral seam per 23 31 13-2; 2.3c• install 256 grilles and diffuserso with return air boots per detail m-300;13 • install 745’ of linear bar grilleo with young regulator in inaccessible ceilings o with sight block • hot water and chilled water exp tanks (one ea) • dallas green globe standardso merv 13 final filterso factory visqueeno blue polyo cxa assist • ddc / ems integrated controls

    Scope• install 2 roof mounted chilled water vav ahu’s (140 tons)o with ddc controlso with vfd’so with disconnectso with drain pans under the chw coils • install 10 chilled water fan coil units (11 tons)o with ddc controls • install 63 vav’s with hydronic heat o with ddc controlso with zero line gyp board access doors where inaccessible o with drain pans and leak detection • install 2 roof mounted ventset exhaust fanso with vfdo with isolation rails • install 3 inline exhaust fanso with spring isolation • install 4 electric unit heatersinstall 20 fire and fire smoke dampers• install 6 fire smoke dampers not drawn • install 2 low leak motorized control dampers• install 4 roof mounted sound attenuators • all round ductwork is quoted as spiral seam per 23 31 13-2; 2.3c• install 256 grilles and diffuserso with return air boots per detail m-300;13 • install 745’ of linear bar grilleo with young regulator in inaccessible ceilings o with sight block • hot water and chilled water exp tanks (one ea) • dallas green globe standardso merv 13 final filterso factory visqueeno blue polyo cxa assist • ddc / ems integrated controls

    City of Dallas permitCommercial Mechanical Permit
    Record
    COM-MEC-26-001482
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  15. Scope• install 2 roof mounted chilled water vav ahu’s (140 tons)o with ddc controlso with vfd’so with disconnectso with drain pans under the chw coils • install 10 chilled water fan coil units (11 tons)o with ddc controls • install 63 vav’s with hydronic heat o with ddc controlso with zero line gyp board access doors where inaccessible o with drain pans and leak detection • install 2 roof mounted ventset exhaust fanso with vfdo with isolation rails • install 3 inline exhaust fanso with spring isolation • install 4 electric unit heatersinstall 20 fire and fire smoke dampers• install 6 fire smoke dampers not drawn • install 2 low leak motorized control dampers• install 4 roof mounted sound attenuators • all round ductwork is quoted as spiral seam per 23 31 13-2; 2.3c• install 256 grilles and diffuserso with return air boots per detail m-300;13 • install 745’ of linear bar grilleo with young regulator in inaccessible ceilings o with sight block • hot water and chilled water exp tanks (one ea) • dallas green globe standardso merv 13 final filterso factory visqueeno blue polyo cxa assist • ddc / ems integrated controls

    Scope• install 2 roof mounted chilled water vav ahu’s (140 tons)o with ddc controlso with vfd’so with disconnectso with drain pans under the chw coils • install 10 chilled water fan coil units (11 tons)o with ddc controls • install 63 vav’s with hydronic heat o with ddc controlso with zero line gyp board access doors where inaccessible o with drain pans and leak detection • install 2 roof mounted ventset exhaust fanso with vfdo with isolation rails • install 3 inline exhaust fanso with spring isolation • install 4 electric unit heatersinstall 20 fire and fire smoke dampers• install 6 fire smoke dampers not drawn • install 2 low leak motorized control dampers• install 4 roof mounted sound attenuators • all round ductwork is quoted as spiral seam per 23 31 13-2; 2.3c• install 256 grilles and diffuserso with return air boots per detail m-300;13 • install 745’ of linear bar grilleo with young regulator in inaccessible ceilings o with sight block • hot water and chilled water exp tanks (one ea) • dallas green globe standardso merv 13 final filterso factory visqueeno blue polyo cxa assist • ddc / ems integrated controls

    City of Dallas permitCommercial Mechanical Permit
    Record
    COM-MEC-26-001483
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  16. Scope• install 2 roof mounted chilled water vav ahu’s (140 tons)o with ddc controlso with vfd’so with disconnectso with drain pans under the chw coils • install 10 chilled water fan coil units (11 tons)o with ddc controls • install 63 vav’s with hydronic heat o with ddc controlso with zero line gyp board access doors where inaccessible o with drain pans and leak detection • install 2 roof mounted ventset exhaust fanso with vfdo with isolation rails • install 3 inline exhaust fanso with spring isolation • install 4 electric unit heatersinstall 20 fire and fire smoke dampers• install 6 fire smoke dampers not drawn • install 2 low leak motorized control dampers• install 4 roof mounted sound attenuators • all round ductwork is quoted as spiral seam per 23 31 13-2; 2.3c• install 256 grilles and diffuserso with return air boots per detail m-300;13 • install 745’ of linear bar grilleo with young regulator in inaccessible ceilings o with sight block • hot water and chilled water exp tanks (one ea) • dallas green globe standardso merv 13 final filterso factory visqueeno blue polyo cxa assist • ddc / ems integrated controls

    Scope• install 2 roof mounted chilled water vav ahu’s (140 tons)o with ddc controlso with vfd’so with disconnectso with drain pans under the chw coils • install 10 chilled water fan coil units (11 tons)o with ddc controls • install 63 vav’s with hydronic heat o with ddc controlso with zero line gyp board access doors where inaccessible o with drain pans and leak detection • install 2 roof mounted ventset exhaust fanso with vfdo with isolation rails • install 3 inline exhaust fanso with spring isolation • install 4 electric unit heatersinstall 20 fire and fire smoke dampers• install 6 fire smoke dampers not drawn • install 2 low leak motorized control dampers• install 4 roof mounted sound attenuators • all round ductwork is quoted as spiral seam per 23 31 13-2; 2.3c• install 256 grilles and diffuserso with return air boots per detail m-300;13 • install 745’ of linear bar grilleo with young regulator in inaccessible ceilings o with sight block • hot water and chilled water exp tanks (one ea) • dallas green globe standardso merv 13 final filterso factory visqueeno blue polyo cxa assist • ddc / ems integrated controls

    City of Dallas permitCommercial Mechanical Permit
    Record
    COM-MEC-26-001484
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  17. Electrical for new construction, site work

    Electrical for new construction, site work

    City of Dallas permitCommercial Electrical Permit
    Record
    COM-ELC-26-002711
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  18. Site work for new ground up business school sewer and water

    Site work for new ground up business school sewer and water

    City of Dallas permitCommercial Plumbing Permit
    Record
    COM-PLM-26-002235
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  19. Filing

    City of Dallas permitPhase - New Construction
    Record
    COM-PH-NEW-26-000657
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  20. Dsst-unv dallas baptist fourth floor

    Dsst-unv dallas baptist fourth floor

    City of Dallas permitPhase - New Construction
    Record
    COM-PH-NEW-26-000656
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  21. Dsst-unv dallas baptist third floor

    Dsst-unv dallas baptist third floor

    City of Dallas permitPhase - New Construction
    Record
    COM-PH-NEW-26-000655
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  22. Dsst-unv dallas baptist second floor

    Dsst-unv dallas baptist second floor

    City of Dallas permitPhase - New Construction
    Record
    COM-PH-NEW-26-000654
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  23. Dsst-unv dallas baptist first floor

    Dsst-unv dallas baptist first floor

    City of Dallas permitPhase - New Construction
    Record
    COM-PH-NEW-26-000653
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  24. Dsst-unv dallas baptist lower level

    Dsst-unv dallas baptist lower level

    City of Dallas permitPhase - New Construction
    Record
    COM-PH-NEW-26-000652
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  25. Dsst-unv dallas baptist site work

    Dsst-unv dallas baptist site work

    City of Dallas permitPhase - New Construction
    Record
    COM-PH-NEW-26-000651
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  26. Filing

    City of Dallas permitPhase - New Construction
    Record
    COM-PH-NEW-26-000659
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  27. Filing

    City of Dallas permitPhase - New Construction
    Record
    COM-PH-NEW-26-000660
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  28. Filing

    City of Dallas permitPhase - New Construction
    Record
    COM-PH-NEW-26-000661
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  29. Not assocated with a project duplicate dsst-unv dallas baptist new business school building

    Not assocated with a project duplicate dsst-unv dallas baptist new business school building

    City of Dallas permitPhase - New Construction
    Record
    COM-PH-NEW-26-000662
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  30. Filing

    City of Dallas permitPhase - New Construction
    Record
    COM-PH-NEW-26-000658
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  31. Dsst-unv dallas baptist new business school building 4 stories plus basement

    Dsst-unv dallas baptist new business school building 4 stories plus basement

    City of Dallas permitCommercial New Construction Permit
    Record
    COM-NEW-25-000244
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  32. Dsst demolish strickland building, haul off all debris. no trees

    Dsst demolish strickland building, haul off all debris. no trees

    City of Dallas permitCommercial Demolition Permit
    Record
    COM-DEM-25-000066
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  33. Install ufer ground in slab

    Install ufer ground in slab

    City of Dallas permitCommercial Electrical Permit
    Record
    COM-ELC-25-002466
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  34. Temporary bleachers

    Temporary bleachers

    City of Dallas permitCommercial Accessory Structure Permit
    Record
    COM-ACC-25-000021
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro

Sources: City of Dallas

Questions about 3000 Mountain Creek Pkwy

What is being built at 3000 Mountain Creek Pkwy?

City of Dallas permits indicate a new commercial building is under construction. The available records do not identify its intended use.

When was construction at 3000 Mountain Creek Pkwy permitted?

The first filing in the records was May 22, 2025. Plumbing permits describing ground-up construction were filed July 8, 2026.

Is the building at 3000 Mountain Creek Pkwy more than one story?

Electrical permits filed July 13, 2026, reference work on the first, second, third and fourth floors.

What work is permitted at 3000 Mountain Creek Pkwy?

City records include plumbing permits for sewer, water and storm work, electrical permits for new construction, and mechanical permits for heating, ventilation and air-conditioning equipment.

What is the permit number for electrical work at 3000 Mountain Creek Pkwy?

The City of Dallas issued several electrical permit records dated July 13, 2026, including COM-ELC-26-003118 for fourth-floor work and COM-ELC-26-003114 for first-floor work.

Also being built nearby

All of 75211

More demolitions in 75211, warehouses & industrial in 75211, restaurants in 75211.

Get alerts for 3000 Mountain Creek Pkwy