Active · latest filing Oct 2026Residential
6237 Malcolm Dr
Dallas, TX 75214
Residential addition permitted at 6237 Malcolm Dr
A residential addition is indicated by a City of Dallas permit filed October 29, 2026, for 6237 Malcolm Dr. Permit RES-ALT-ADD-26-001885 does not list the addition's size or valuation.
Summarized from City of Dallas records · updated Oct 29, 2026
- Projects
- 1
- 1 filings
- Latest filing
- Oct 29, 2026
- since Oct 29, 2026
- Largest scope
- —
- Listed value
- —
Permit & project history
1 projectSources: City of Dallas
Questions about 6237 Malcolm Dr
What is being built at 6237 Malcolm Dr in Dallas?
A City of Dallas permit records a residential addition at the address. It does not provide further details about the work.
When was the addition at 6237 Malcolm Dr permitted?
The permit was filed on October 29, 2026.
What is the permit number for 6237 Malcolm Dr?
The permit number is RES-ALT-ADD-26-001885. It is listed as a Residential Alteration Addition Permit.
How large is the residential addition at 6237 Malcolm Dr?
The permit record does not include a square-footage figure.
How much will the addition at 6237 Malcolm Dr cost?
The permit record does not list a project valuation or cost estimate.
Also being built nearby
All of 75214- 6236 Malcolm DrFeb 24, 2026Demolition of house · 13 m away
- 6227 Malcolm DrAug 18, 2025Installed new hvac · 37 m away
- 6221 Malcolm DrFeb 3, 2026Install 1 50-gal gas water heater in pull down attic · 60 m away
- 6240 Revere PlNov 9, 2026Installing new yard gas service and running pipe in attic for water heater and furnace · 79 m away
- 6226 Revere PlNov 13, 2026Install 8' fence · 86 m away
- 6231 Mccommas BlvdAug 1, 2025Sidewalk removal and replace of 4x27. a new driveway was done recently and the owner wanted to go ahead and get all the row new · 100 m away
- 6239 Mccommas BlvdNov 4, 2025Gas repair with pressure test · 103 m away
- 6223 Revere PlAug 27, 2026Replace the existing 100 amp federal pacific stab-lok load center with a new 200amp service.install a new 2 inch rigid galvanized steel service mast, weatherhead, and roofflashing. install a new 200 amp ringless meter socket on the exterior wall at theheight required by oncor. install new 2/0 awg copper service entrance conductors.install a new 200 amp, 42 space, nema 3r main breaker load center on the exteriorwall. the existing load center is in an interior pantry that cannot provide therequired working clearance in front of a panel, so the new load center is installedoutdoors. the outdoor main breaker serves as the emergency disconnect.remove the existing federal pacific load center. install junction enclosures at theformer panel location and re-route 26 existing branch circuits through the attic tothe new load center.install a whole house surge protective device.install a new grounding electrode system consisting of two 5/8 inch by 8 foot groundrods, a cold water pipe bond, an intersystem bonding termination, and a #4 awg barecopper grounding electrode conductor. install insulated grounding bushings andsupply side bonding jumpers on the service raceway · 104 m away
- 6242 Mccommas BlvdOct 28, 202641ft board on board cedar fence no taller than 9ft · 114 m away
- 6257 Revere PlNov 16, 2020Demolition sfd · 118 m away
- 6212 Revere PlJan 27, 2021Gas relay or repair with test · 118 m away
- 6263 Revere PlMar 25, 20268' wood fence3 gates · 124 m away