groundranger
Historic · latest filing Nov 2020Commercial

2002 Elmwood Blvd

Dallas, TX 75224

2002 Elmwood Blvd: 1 project on record

City of Dallas lists 1 filing across 1 project at 2002 Elmwood Blvd, Dallas, TX 75224. The most recent, filed November 16, 2020, covers: “Gas test”.

Compiled from City of Dallas records · updated Nov 16, 2020

Projects
1
1 filings
Latest filing
Nov 16, 2020
since Nov 16, 2020
Largest scope
—
Listed value
$95
partial · often understated

Permit & project history

1 project
  1. Gas test

    Gas test

    City of Dallas permitPlumbing (PL) Single Family Alteration$95
    Record
    2011163119
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro

Sources: City of Dallas

Questions about 2002 Elmwood Blvd

What is being built at 2002 Elmwood Blvd?

The latest filing (City of Dallas permit 2011163119, November 16, 2020) covers gas test.

How many permits and filings does 2002 Elmwood Blvd have?

1 filing across 1 project, from November 16, 2020 to November 16, 2020.

How much is the construction at 2002 Elmwood Blvd worth?

Permits at this address list about $95 in valuations. Permit valuations are often partial and understate total project cost.

Is there other construction near 2002 Elmwood Blvd?

Yes. Nearby filings include 2010 Elmwood Blvd (gas test only, Aug 13, 2025); 2030 Elmwood Blvd (no work performed neighbour's house caught fire and caught their garage on fire oncor took their meter and wanted them to have a permit pulled and a inspection done. our tech said there is no fire damage to the electrical, Mar 30, 2026); 2034 Elmwood Blvd (this recommended option includes a complete upgrade of the home’s electrical service to restore power in a safe, reliable, and fully code-compliant manner following fire damage to the existing overhead service.work to be performed includes removal of the damaged and non-compliant existing service equipment, including the current seu service conductors and zinsco panel.installation of a new 200-amp electrical service will be performed in accordance with current code and utility requirements. this includes installation of a rigid, through-the-roof service mast as required by oncor’s most recent service standards to allow for reconnection of power.a new 200-amp outdoor-rated main breaker panel will be installed to replace the existing zinsco panel, bringing the system up to current safety standards and meeting city of dallas requirements.this option includes installation of a 36ka whole-home surge protector, providing protection for the home’s electrical system and appliances against common voltage spikes and surges.a full grounding system will be installed to meet current nec requirements. this includes proper grounding electrode installation and bonding of the electrical system to ensure safety and compliance.additionally, we will install three wireless interconnected smoke detectors to improve life safety within the home. these units will communicate with each other to provide full-home notification in the event of smoke or fire detection.all work will be performed under a city of dallas electrical permit. the installation will be inspected and must pass inspection before the utility provider (oncor) will reconnect power to the home.applicable nec code references:nec 230.50 – protection against physical damagenec 230.54 – overhead service locations (service mast requirements)nec 230.70 – service disconnect requirementsnec 250.50 – grounding electrode systemnec 250.53 – grounding electrode installationnec 285 – surge protective devicesnec 408.36 – overcurrent protectionnec 110.12 – mechanical execution of worknec 210.12 / 210.52 – general circuit & safety requirements (as applicable)additional notes:existing seu service and zinsco panel will be removed and replaced as required for compliance.rigid mast service is required by oncor for reconnection.all work must pass city of dallas inspection prior to utility reconnection.coordination with oncor will be required for final re-energization.power will remain off until all work is completed, inspected, and approved.change order and scope addendum:any changes to the outlined scope of work, including unforeseen conditions, limited or restricted access, or scheduling constraints, may require a change order. any additional work will be discussed and approved by the customer prior to proceeding, Apr 20, 2026).

How do I get alerts for new permits at 2002 Elmwood Blvd?

Watch this address on groundranger and you'll get an email when a new permit or project filing appears here or nearby.

Also being built nearby

All of 75224
Get alerts for 2002 Elmwood Blvd