2030 Elmwood Blvd
Dallas, TX 75224
Residential electrical permit filed at 2030 Elmwood Blvd
A residential electrical permit was filed at 2030 Elmwood Blvd on March 30, 2026. The permit record says no work was performed at the property and that the permit and inspection were requested after a neighboring house and garage caught fire; the technician reported no electrical fire damage at this address.
Summarized from City of Dallas records · updated Mar 30, 2026
- Projects
- 1
- 1 filings
- Latest filing
- Mar 30, 2026
- since Mar 30, 2026
- Largest scope
- —
- Listed value
- —
Permit & project history
1 projectNo work performed neighbour's house caught fire and caught their garage on fire oncor took their meter and wanted them to have a permit pulled and a inspection done. our tech said there is no fire damage to the electrical
No work performed neighbour's house caught fire and caught their garage on fire oncor took their meter and wanted them to have a permit pulled and a inspection done. our tech said there is no fire damage to the electrical
City of Dallas permitResidential Electrical Permit
Sources: City of Dallas
Questions about 2030 Elmwood Blvd
What is being built at 2030 Elmwood Blvd?
The City of Dallas record is for a residential electrical permit, not a new building project. Its note says no work was performed at the address.
When was the electrical permit filed for 2030 Elmwood Blvd?
The permit was filed on March 30, 2026. Its number is RES-ELC-26-001789.
Was there a fire at 2030 Elmwood Blvd?
The permit note says a neighboring house and garage caught fire. It also says the technician reported no electrical fire damage at 2030 Elmwood Blvd.
Why was an electrical permit requested at 2030 Elmwood Blvd?
According to the permit note, Oncor removed the meter and wanted a permit and inspection. The note says no work was performed at the property.
What work does permit RES-ELC-26-001789 cover?
The record identifies it as a residential electrical permit. Its description says no electrical work was performed at the address.
Also being built nearby
All of 75224- 2034 Elmwood BlvdApr 20, 2026This recommended option includes a complete upgrade of the home’s electrical service to restore power in a safe, reliable, and fully code-compliant manner following fire damage to the existing overhead service.work to be performed includes removal of the damaged and non-compliant existing service equipment, including the current seu service conductors and zinsco panel.installation of a new 200-amp electrical service will be performed in accordance with current code and utility requirements. this includes installation of a rigid, through-the-roof service mast as required by oncor’s most recent service standards to allow for reconnection of power.a new 200-amp outdoor-rated main breaker panel will be installed to replace the existing zinsco panel, bringing the system up to current safety standards and meeting city of dallas requirements.this option includes installation of a 36ka whole-home surge protector, providing protection for the home’s electrical system and appliances against common voltage spikes and surges.a full grounding system will be installed to meet current nec requirements. this includes proper grounding electrode installation and bonding of the electrical system to ensure safety and compliance.additionally, we will install three wireless interconnected smoke detectors to improve life safety within the home. these units will communicate with each other to provide full-home notification in the event of smoke or fire detection.all work will be performed under a city of dallas electrical permit. the installation will be inspected and must pass inspection before the utility provider (oncor) will reconnect power to the home.applicable nec code references:nec 230.50 – protection against physical damagenec 230.54 – overhead service locations (service mast requirements)nec 230.70 – service disconnect requirementsnec 250.50 – grounding electrode systemnec 250.53 – grounding electrode installationnec 285 – surge protective devicesnec 408.36 – overcurrent protectionnec 110.12 – mechanical execution of worknec 210.12 / 210.52 – general circuit & safety requirements (as applicable)additional notes:existing seu service and zinsco panel will be removed and replaced as required for compliance.rigid mast service is required by oncor for reconnection.all work must pass city of dallas inspection prior to utility reconnection.coordination with oncor will be required for final re-energization.power will remain off until all work is completed, inspected, and approved.change order and scope addendum:any changes to the outlined scope of work, including unforeseen conditions, limited or restricted access, or scheduling constraints, may require a change order. any additional work will be discussed and approved by the customer prior to proceeding · 6 m away
- 2010 Elmwood BlvdAug 13, 2025Gas test only · 29 m away
- 2002 Elmwood BlvdNov 16, 2020Gas test · 41 m away
- 2114 Elmwood BlvdOct 28, 2020Gas test · 122 m away
- 1945 Elmwood BlvdSep 18, 2025Gas test. removed wall space heaters · 128 m away
- 2122 Elmwood BlvdOct 29, 2020Remove existing roof and install new roof · 134 m away
- 1934 Elmwood BlvdDec 11, 2025Electrical for addition · 139 m away
- 2023 Ferndale AveJul 7, 2025Replaced 1" galvanized water service with an 1.25" pex service. installed new main shut off valve and valve box. reconnected to existing front hydrant in the yard · 139 m away
- 2126 Elmwood BlvdJan 14, 2021Gas test · 140 m away
- 2014 Ferndale AveOct 21, 2020Install water heater · 140 m away
- 1930 Elmwood BlvdSep 22, 2020Remove existing roof and install new roof · 145 m away
- 2129 Elmwood BlvdApr 20, 2026Replace drain under slab pier and beam house · 145 m away