2014 Ferndale Ave
Dallas, TX 75224
2014 Ferndale Ave: 1 project on record
City of Dallas lists 1 filing across 1 project at 2014 Ferndale Ave, Dallas, TX 75224. The most recent, filed October 21, 2020, covers: “Install water heater”.
Compiled from City of Dallas records · updated Oct 21, 2020
- Projects
- 1
- 1 filings
- Latest filing
- Oct 21, 2020
- since Oct 21, 2020
- Largest scope
- —
- Listed value
- $5
- partial · often understated
Permit & project history
1 projectSources: City of Dallas
Questions about 2014 Ferndale Ave
What is being built at 2014 Ferndale Ave?
The latest filing (City of Dallas permit 2010213008, October 21, 2020) covers install water heater.
How many permits and filings does 2014 Ferndale Ave have?
1 filing across 1 project, from October 21, 2020 to October 21, 2020.
How much is the construction at 2014 Ferndale Ave worth?
Permits at this address list about $5 in valuations. Permit valuations are often partial and understate total project cost.
Is there other construction near 2014 Ferndale Ave?
Yes. Nearby filings include 2023 Ferndale Ave (replaced 1" galvanized water service with an 1.25" pex service. installed new main shut off valve and valve box. reconnected to existing front hydrant in the yard, Jul 7, 2025); 1938 Newport Ave (remove old composition shingles & install new composition shingles, Apr 13, 2026); 1930 Newport Ave (new master bedroom, closet and bathroom addition, Mar 27, 2025).
How do I get alerts for new permits at 2014 Ferndale Ave?
Watch this address on groundranger and you'll get an email when a new permit or project filing appears here or nearby.
Also being built nearby
All of 75224- 2023 Ferndale AveJul 7, 2025Replaced 1" galvanized water service with an 1.25" pex service. installed new main shut off valve and valve box. reconnected to existing front hydrant in the yard · 18 m away
- 1938 Newport AveApr 13, 2026Remove old composition shingles & install new composition shingles · 102 m away
- 1930 Newport AveMar 27, 2025New master bedroom, closet and bathroom addition · 114 m away
- 2114 Elmwood BlvdOct 28, 2020Gas test · 119 m away
- 2014 Berkley AveSep 21, 2020Remove existing roof and install new roof · 120 m away
- 2122 Elmwood BlvdOct 29, 2020Remove existing roof and install new roof · 121 m away
- 2010 Berkley AveDec 3, 2020Remodel · 121 m away
- 2126 Elmwood BlvdJan 14, 2021Gas test · 122 m away
- 2129 Elmwood BlvdApr 20, 2026Replace drain under slab pier and beam house · 135 m away
- 2034 Elmwood BlvdApr 20, 2026This recommended option includes a complete upgrade of the home’s electrical service to restore power in a safe, reliable, and fully code-compliant manner following fire damage to the existing overhead service.work to be performed includes removal of the damaged and non-compliant existing service equipment, including the current seu service conductors and zinsco panel.installation of a new 200-amp electrical service will be performed in accordance with current code and utility requirements. this includes installation of a rigid, through-the-roof service mast as required by oncor’s most recent service standards to allow for reconnection of power.a new 200-amp outdoor-rated main breaker panel will be installed to replace the existing zinsco panel, bringing the system up to current safety standards and meeting city of dallas requirements.this option includes installation of a 36ka whole-home surge protector, providing protection for the home’s electrical system and appliances against common voltage spikes and surges.a full grounding system will be installed to meet current nec requirements. this includes proper grounding electrode installation and bonding of the electrical system to ensure safety and compliance.additionally, we will install three wireless interconnected smoke detectors to improve life safety within the home. these units will communicate with each other to provide full-home notification in the event of smoke or fire detection.all work will be performed under a city of dallas electrical permit. the installation will be inspected and must pass inspection before the utility provider (oncor) will reconnect power to the home.applicable nec code references:nec 230.50 – protection against physical damagenec 230.54 – overhead service locations (service mast requirements)nec 230.70 – service disconnect requirementsnec 250.50 – grounding electrode systemnec 250.53 – grounding electrode installationnec 285 – surge protective devicesnec 408.36 – overcurrent protectionnec 110.12 – mechanical execution of worknec 210.12 / 210.52 – general circuit & safety requirements (as applicable)additional notes:existing seu service and zinsco panel will be removed and replaced as required for compliance.rigid mast service is required by oncor for reconnection.all work must pass city of dallas inspection prior to utility reconnection.coordination with oncor will be required for final re-energization.power will remain off until all work is completed, inspected, and approved.change order and scope addendum:any changes to the outlined scope of work, including unforeseen conditions, limited or restricted access, or scheduling constraints, may require a change order. any additional work will be discussed and approved by the customer prior to proceeding · 137 m away
- 1914 Newport AveSep 23, 2020Garage conversion interior/exterior remodel · 138 m away
- 2030 Elmwood BlvdMar 30, 2026No work performed neighbour's house caught fire and caught their garage on fire oncor took their meter and wanted them to have a permit pulled and a inspection done. our tech said there is no fire damage to the electrical · 140 m away