groundranger
Active · latest filing Aug 2026Residential

9952 Parkford Dr

Dallas, TX 75238

Dallas permit covers removal of an interior partition wall

A residential alteration permit filed August 25, 2026, covers removing a non-load-bearing partition wall at 9952 Parkford Dr and rerouting electrical wiring. The permit also describes removing a light fixture, switch, junction box and GFCI outlet associated with the wall.

Summarized from City of Dallas records · updated Aug 25, 2026

Projects
1
1 filings
Latest filing
Aug 25, 2026
since Aug 25, 2026
Largest scope
—
Listed value
—

Permit & project history

1 project
  1. Nsfaa proposed detailed description of work: remove an existing 7?ft tall by 10?ft non?load?bearing partition wall, including demolition and disposal of wall materials. work includes removal of one junction box, one light fixture with its switch, and one gfci outlet that were previously mounted on the wall being removed.install approximately 20 linear feet of new 12/2 romex cable routed continuously through the attic from the original circuit location to the new connection point. provide proper support with staples every 4 feet along horizontal runs. extend power to a new 4?gang junction box located on the north side of the upstairs area, then route conductors up through the fur?down and into the remaining structural post, reconnecting to the existing junction box that originally served the removed wall.all wiring will be terminated inside approved enclosures, secured per nec requirements, and connected to the existing 20?amp breaker supplying the circuit. no load?bearing structural components are altered

    Nsfaa proposed detailed description of work: remove an existing 7?ft tall by 10?ft non?load?bearing partition wall, including demolition and disposal of wall materials. work includes removal of one junction box, one light fixture with its switch, and one gfci outlet that were previously mounted on the wall being removed.install approximately 20 linear feet of new 12/2 romex cable routed continuously through the attic from the original circuit location to the new connection point. provide proper support with staples every 4 feet along horizontal runs. extend power to a new 4?gang junction box located on the north side of the upstairs area, then route conductors up through the fur?down and into the remaining structural post, reconnecting to the existing junction box that originally served the removed wall.all wiring will be terminated inside approved enclosures, secured per nec requirements, and connected to the existing 20?amp breaker supplying the circuit. no load?bearing structural components are altered

    City of Dallas permitResidential Alteration Addition Permit
    Record
    RES-ALT-ADD-26-001598
    Owner
    Pro
    Contractor
    Pro
    Contact
    Pro

Sources: City of Dallas

Questions about 9952 Parkford Dr

What is being changed at 9952 Parkford Dr?

A City of Dallas permit describes removing an existing non-load-bearing partition wall and rerouting electrical wiring. The filing date is August 25, 2026.

Is a new building being built at 9952 Parkford Dr?

The permit describes an alteration to a residence, not new construction. The work includes removing an interior partition wall and electrical components mounted on it.

When was the permit filed for 9952 Parkford Dr?

The City of Dallas permit was filed August 25, 2026. Its number is RES-ALT-ADD-26-001598.

Will the work at 9952 Parkford Dr affect a load-bearing wall?

The permit description calls the partition wall non-load-bearing and says no load-bearing structural components will be altered.

Does the 9952 Parkford Dr permit include electrical work?

Yes. It describes installing about 20 linear feet of new wiring and extending power to a new junction box, with connections to the existing circuit.