New townhomes in Dallas 75231
4 addresses in 75231 have permits or project filings for townhomes in the last two years. The most recent was filed at 7023 Kingsbury Dr.
Latest filings
- 7023 Kingsbury DrAug 31, 2026Complete electrical service change for both dwelling units of a two-family duplex at 7021 and 7023 kingsbury dr. each unit is currently served by a 150 amp fused service with a federal pacific stab-lok load center located in a clothes closet. the scope below is performed twice, once per dwelling unit.service, 2 required: remove the existing fused service disconnect and obsolete meter socket at each unit. install two new service masts of 2 inch rigid metal conduit with weatherhead, point of attachment hardware, and roof flashing, connected to the existing overhead service drop. install new 2/0 copper service entrance conductors, three conductors per unit. install two new 200 amp ringless meter-main combinations (square d rc200s with 200 amp main breaker), one per unit, on the exterior rear wall, each set within the utility required meter height and each serving as the service disconnecting means for its own unit. each marked per nec 230.85. each meter socket permanently identified with its unit address per utility requirements for multi-metered locations.load centers, 2 required: remove both existing federal pacific stab-lok load centers from clothes closets. install two new 42 space main lug load centers, 225 amp bus, one per unit, at code compliant locations. each supplied by a 200 amp feeder of 4/0 aluminum ser, approximately 60 feet per unit, from that unit's service disconnect. each existing panel enclosure to be retained as an accessible junction box with blank cover. existing branch circuits to be spliced and extended to the new load center, then identified and labeled with a circuit directory per nec 408.4(a). approximately 18 branch circuits per unit.grounding and bonding, 2 required: new grounding electrode system at each unit consisting of two 8 foot driven ground rods, #4 bare copper grounding electrode conductor sized per nec 250.66, water pipe bond, and intersystem bonding termination. each load center neutral isolated from equipment ground per nec 250.24 and 250.142.other: install a whole panel surge protective device at each load center per nec 230.67. install branch circuit overcurrent devices. coordinate meter removal and reset with oncor for both meters.existing branch circuit conductors remain in place. no branch circuit rewiring is included in this scope
- 7121 Pleasant View DrMar 10, 2026We are only doing work on one side of the duplex (7123). replace existing 50-gallon natural gas water heater with a new 50-gallon natural gas water heater in the same location
- 7473 Walling LnMay 15, 2025The house is a duplex (7471/7473) and the previous owner supplied both sides from the 7471 meter, letting the 7473 meter lie unused. this application is for reconnecting the 7473 supply line to the 7473 meter. there is a branch off of the 7471 supply that will be removed so that both sides are fed straight from their meters
- 7471 Walling LnMay 14, 2025The house is a duplex (7471/7473) and the previous owner supplied both sides from the 7471 meter, letting the 7473 meter lie unused. this application is for reconnecting the 7473 supply line to the 7473 meter. there is a branch off of the 7471 supply that will be removed so that both sides are fed straight from their meters
Questions
What townhomes are being built in Dallas 75231?
4 addresses in 75231 have permits or project filings for townhomes in the last two years. The most recent was filed at 7023 Kingsbury Dr. Others include 7121 Pleasant View Dr, 7473 Walling Ln, 7471 Walling Ln.
How can I find out when a new townhome is permitted near me?
Watch your ZIP code or address on groundranger to get an email as soon as a new townhome permit is filed.