3701 Grooms St

Austin, TX 78705

Electrical permit moves a chandelier at 3701 Grooms St

An electrical permit filed October 13, 2025, covers relocating a chandelier at 3701 Grooms St. The work extends the existing light circuit about 8 feet so the fixture can be centered in the building.

Summarized from City of Austin records · updated Oct 13, 2025

Projects
1
1 filings
Latest filing
Oct 13, 2025
since Oct 13, 2025
Largest scope
—
Listed value
—

Where this project stands

Finaled

Extended electrical conduit and conductors to relocate a light fixture. work description: utilize existing light circuit with wall switch. extend circuit ~8 feet so chandelier can be centered in the building. install 12 awg thhn copper conductors (hot neutral ground). run conductors in 3/4 metal conduit with metallic fittings for fire protection. provide and install listed ceiling box/support rated for 50 lbs (fixture is ~10 lbs). mount chandelier per manufacturers instructions. bond all metal components to equipment grounding conductor. test for continuity grounding and correct polarity. update panel schedule to reflect new fixture location

  1. AppliedSep 18, 2025
  2. IssuedOct 13, 2025
  3. WorkOct '25 – Oct '25
  4. Final inspectionJul 13, 2026

Passed final inspection Jul 13, 2026.

1 contact on this project · 1 phone number

Permit & project history

1 project
  1. Extended electrical conduit and conductors to relocate a light fixture. work description: utilize existing light circuit with wall switch. extend circuit ~8 feet so chandelier can be centered in the building. install 12 awg thhn copper conductors (hot neutral ground). run conductors in 3/4 metal conduit with metallic fittings for fire protection. provide and install listed ceiling box/support rated for 50 lbs (fixture is ~10 lbs). mount chandelier per manufacturers instructions. bond all metal components to equipment grounding conductor. test for continuity grounding and correct polarity. update panel schedule to reflect new fixture location

    Extended electrical conduit and conductors to relocate a light fixture. work description: utilize existing light circuit with wall switch. extend circuit ~8 feet so chandelier can be centered in the building. install 12 awg thhn copper conductors (hot neutral ground). run conductors in 3/4 metal conduit with metallic fittings for fire protection. provide and install listed ceiling box/support rated for 50 lbs (fixture is ~10 lbs). mount chandelier per manufacturers instructions. bond all metal components to equipment grounding conductor. test for continuity grounding and correct polarity. update panel schedule to reflect new fixture location

    City of Austin permitElectrical PermitFinal
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro

Sources: City of Austin

Questions about 3701 Grooms St

What work is permitted at 3701 Grooms St?

The City of Austin permit covers extending an existing light circuit about 8 feet and installing a ceiling box and chandelier support.

When was the electrical permit for 3701 Grooms St filed?

The permit was filed on October 13, 2025.

What is the permit number for work at 3701 Grooms St?

The City of Austin permit number is 2025-119232 EP.

Is a new building being constructed at 3701 Grooms St?

The listed permit is for electrical work to relocate a light fixture, not for construction of a new building.

Does the permit at 3701 Grooms St involve a new light circuit?

No new circuit is described. The work uses the existing light circuit and extends it about 8 feet.