Electrical service upgrade permitted at 706 North Bluff Dr
An electrical service upgrade was permitted at 706 North Bluff Dr in Austin on September 24, 2025. Permit 2025-101265 EP covers a new 320-amp meter base, service disconnects, electrical panel and grounding and surge-protection equipment; it does not specify a new business or use.
Summarized from City of Austin records · updated Sep 24, 2025
- Projects
- 1
- 1 filings
- Latest filing
- Sep 24, 2025
- since Sep 24, 2025
- Largest scope
- —
- Listed value
- —
Where this project stands
FinaledPermit scope of work: electrical service upgrade single phase (320a metered) 1. service entrance and metering remove existing meter base and overhead riser. install new overhead service riser with weatherhead and mast for single-phase service. install new 320a continuous-rated meter base compatible with oncor/pec and austin energy. 2. main disconnects and gutter install one 125-amp surface-mounted service-rated disconnect. install one 200-amp surface-mounted service-rated disconnect. install 4-foot metal gutter (wireway) mounted above the disconnects to manage incoming and outgoing conductors. 3. panel and distribution equipment remove all existing electrical panels. install one new 200/225 amp 42-space indoor main lug panel surface-mounted. 4. grounding and bonding install two 8-foot copper ground rods connected with #4 copper wire to establish the main grounding system. install gas bond using #4 copper 2140 feet in length from the gas line to the main panel. install water bond using #4 copper from an outdoor hose bib to the main panel. 5. surge protection install a whole-home surge protector at the main panel
- AppliedAug 11, 2025
- IssuedSep 24, 2025
- WorkSep '25 – Oct '25
- Final inspectionOct 28, 2025
Passed final inspection Oct 28, 2025.
1 contact on this project · 1 phone number
Permit & project history
1 projectPermit scope of work: electrical service upgrade single phase (320a metered) 1. service entrance and metering remove existing meter base and overhead riser. install new overhead service riser with weatherhead and mast for single-phase service. install new 320a continuous-rated meter base compatible with oncor/pec and austin energy. 2. main disconnects and gutter install one 125-amp surface-mounted service-rated disconnect. install one 200-amp surface-mounted service-rated disconnect. install 4-foot metal gutter (wireway) mounted above the disconnects to manage incoming and outgoing conductors. 3. panel and distribution equipment remove all existing electrical panels. install one new 200/225 amp 42-space indoor main lug panel surface-mounted. 4. grounding and bonding install two 8-foot copper ground rods connected with #4 copper wire to establish the main grounding system. install gas bond using #4 copper 2140 feet in length from the gas line to the main panel. install water bond using #4 copper from an outdoor hose bib to the main panel. 5. surge protection install a whole-home surge protector at the main panel
Permit scope of work: electrical service upgrade single phase (320a metered) 1. service entrance and metering remove existing meter base and overhead riser. install new overhead service riser with weatherhead and mast for single-phase service. install new 320a continuous-rated meter base compatible with oncor/pec and austin energy. 2. main disconnects and gutter install one 125-amp surface-mounted service-rated disconnect. install one 200-amp surface-mounted service-rated disconnect. install 4-foot metal gutter (wireway) mounted above the disconnects to manage incoming and outgoing conductors. 3. panel and distribution equipment remove all existing electrical panels. install one new 200/225 amp 42-space indoor main lug panel surface-mounted. 4. grounding and bonding install two 8-foot copper ground rods connected with #4 copper wire to establish the main grounding system. install gas bond using #4 copper 2140 feet in length from the gas line to the main panel. install water bond using #4 copper from an outdoor hose bib to the main panel. 5. surge protection install a whole-home surge protector at the main panel
City of Austin permitElectrical PermitFinal- Record
- 2025-101265 EP
- Tenant / owner
- Pro
- Contractor
- Pro
- Contact
- Pro
Sources: City of Austin
Questions about 706 North Bluff Dr
What is being built at 706 North Bluff Dr?
A City of Austin permit covers an electrical service upgrade, including a new meter base, disconnects and panel. The permit does not describe a new building or business.
When was the electrical work at 706 North Bluff Dr permitted?
The permit was filed September 24, 2025. Its number is 2025-101265 EP, and its status is listed as Final.
Is a new business opening at 706 North Bluff Dr?
The permit describes electrical service work, not a new business or tenant. It does not identify an occupant.
What electrical work is planned at 706 North Bluff Dr?
The scope includes replacing the existing meter base and panels, installing a new 320-amp meter base and two service disconnects, and adding grounding and surge protection. The permit is 2025-101265 EP.
What construction is happening near 7 Brew on East William Cannon Drive?
A City of Austin permit filed September 24, 2025, covers an electrical service upgrade at 706 North Bluff Dr, about 398 meters from 7 Brew Austin, TX. It does not specify a new business or use.
Is there a new restaurant planned near China Harbor Restaurant?
The record for 706 North Bluff Dr, about 399 meters from China Harbor Restaurant, is for an electrical service upgrade. It does not identify a restaurant or other new tenant.
Also being built nearby
All of 78745- 6300 IH 35 SvrdMar 2, 2007Capitol chevrolet sales office addition · 134 m away
- 700 North Bluff DrMar 9, 2015Capitol chevrolet auto parts building · 139 m away
- 814 North Bluff DrDec 3, 2024Installation of underground fireline ok per cory harmon 12/17/19 reference pp# 19-065718 for underground utilities · 141 m away
- 812-1/2 North Bluff DrSep 10, 2024Test pf sp · 143 m away
- 801 North Bluff DrDec 4, 2024Replacement of furnace only replace existing air handler · 164 m away
- 705 North Bluff DrSep 2, 2016North bluff 1 · 166 m away
- 6406 N IH 35 Svrd SbNov 5, 2026Maximum ac and heating llc. is working in conjunction with rodge ryan air on permit #2026-032217 to install one icemaker and on walk in cooler · 195 m away
- 6200 IH 35 SvrdMar 2, 2007Capitol chevrolet parking garage · 225 m away
- 6320 IH 35 SvrdMar 2, 2007Capitol chevrolet · 229 m away
- 817 North Bluff DrApr 12, 2019Capital chevrolet vehicle sales inventory lot · 243 m away
- 6412 IH 35 SvrdMar 2, 2007Firestone store · 259 m away
- 604 North Bluff DrNov 4, 2026Replacement of complete existing central heat and air system with or without duct work · 263 m away