groundranger
Recent · latest filing Aug 2026Commercial

1105 Levee St

Dallas, TX 75207

Electrical service upgrades filed at 1105 Levee St

Electrical permits at 1105 Levee St indicate upgrades to the building’s power service, including a new 400-amp, 480-volt service and distribution equipment. The first of three City of Dallas permits was filed October 10, 2025; the latest was filed August 14, 2026.

Summarized from City of Dallas records · updated Aug 14, 2026

Projects
4
4 filings
Latest filing
Aug 14, 2026
since Oct 10, 2025
Largest scope
—
Listed value
—

Permit & project history

4 projects
  1. Primetime electrical contractors will install a new 400-amp electrical service (480volt) for the building to meet current and future power demands. scope includes: • installation of a 400-amp meter base on the exterior of the building in compliance with local utility and nec requirements. • installation of a 400-amp service disconnect adjacent to the meter base to provide a code-compliant means of disconnect. • installation of a 400-amp i-line distribution panel inside the building to serve as the main distribution point for interior loads. • installation of a step-down transformer to reduce the incoming 480v service to 240/120v for existing lighting and receptacle circuits. • wreck out existing interior meter, after the power company cut it off. • all conduit, conductors, grounding, bonding, and terminations will be completed per the code and local authority requirements. • the system will be tested, labeled, and verified for full functionality upon completion

    Primetime electrical contractors will install a new 400-amp electrical service (480volt) for the building to meet current and future power demands. scope includes: • installation of a 400-amp meter base on the exterior of the building in compliance with local utility and nec requirements. • installation of a 400-amp service disconnect adjacent to the meter base to provide a code-compliant means of disconnect. • installation of a 400-amp i-line distribution panel inside the building to serve as the main distribution point for interior loads. • installation of a step-down transformer to reduce the incoming 480v service to 240/120v for existing lighting and receptacle circuits. • wreck out existing interior meter, after the power company cut it off. • all conduit, conductors, grounding, bonding, and terminations will be completed per the code and local authority requirements. • the system will be tested, labeled, and verified for full functionality upon completion

    City of Dallas permitCommercial Electrical Permit
    Record
    COM-ELC-26-003818
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  2. Primetime electrical contractors will install a new 400-amp electrical service (480volt) for the building to meetcurrent and future power demands.scope includes:• installation of a 400-amp meter base on the exterior of the building in compliance with local utility andnec requirements.• installation of a 400-amp service disconnect adjacent to the meter base to provide a code-compliantmeans of disconnect.• installation of a 400-amp island distribution panel inside the building to serve as the main distributionpoint for interior loads.• installation of a step-down transformer to reduce the incoming 480v service to 240/120v for existinglighting and receptacle circuits.• relocation of the existing interior meter to the exterior location to ensure accessibility and compliancewith utility company regulations.• all conduit, conductors, grounding, bonding, and terminations will be completed per the 2020 neccode and local authority requirements.• the system will be tested, labeled, and verified for full functionality upon completion

    Primetime electrical contractors will install a new 400-amp electrical service (480volt) for the building to meetcurrent and future power demands.scope includes:• installation of a 400-amp meter base on the exterior of the building in compliance with local utility andnec requirements.• installation of a 400-amp service disconnect adjacent to the meter base to provide a code-compliantmeans of disconnect.• installation of a 400-amp island distribution panel inside the building to serve as the main distributionpoint for interior loads.• installation of a step-down transformer to reduce the incoming 480v service to 240/120v for existinglighting and receptacle circuits.• relocation of the existing interior meter to the exterior location to ensure accessibility and compliancewith utility company regulations.• all conduit, conductors, grounding, bonding, and terminations will be completed per the 2020 neccode and local authority requirements.• the system will be tested, labeled, and verified for full functionality upon completion

    City of Dallas permitCommercial Electrical Permit
    Record
    COM-ELC-25-002830
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  3. We are relocating the meter, set a 400amp disconnect outside fused , for oncor. inside tapped off a gutter to feed 2- transformers and installed 5 indoor disconnects for existing sevice panels and protect the transformers and providing disconnecting means and feeder protection. existing service panels are 1-150 amp main bkr panel and an existing 200 amp panel. just refeeding the existing panels from the new service location., ran 1- 3 phase circuit for a piece of equipment

    We are relocating the meter, set a 400amp disconnect outside fused , for oncor. inside tapped off a gutter to feed 2- transformers and installed 5 indoor disconnects for existing sevice panels and protect the transformers and providing disconnecting means and feeder protection. existing service panels are 1-150 amp main bkr panel and an existing 200 amp panel. just refeeding the existing panels from the new service location., ran 1- 3 phase circuit for a piece of equipment

    City of Dallas permitCommercial Electrical Permit
    Record
    COM-ELC-25-002632
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro
  4. Install new plumbing

    Install new plumbing

    City of Dallas permitPlumbing (PL) Commercial Alteration
    Record
    1911213003
    Tenant / owner
    Pro
    Contractor
    Pro
    Contact
    Pro

Sources: City of Dallas

Questions about 1105 Levee St

What is being built at 1105 Levee St?

City of Dallas permits indicate electrical service and distribution upgrades to the building, including a new 400-amp, 480-volt service and a step-down transformer.

When were permits filed for work at 1105 Levee St?

The three City of Dallas electrical permits were filed October 10, 2025, October 23, 2025, and August 14, 2026.

What does permit COM-ELC-26-003818 cover?

Filed August 14, 2026, the permit covers a new 400-amp, 480-volt electrical service, an interior distribution panel, and a transformer to supply existing lighting and receptacle circuits.

Is a new building planned at 1105 Levee St?

The records provided list electrical permits for the existing building, not a permit for new construction.

What electrical work was permitted at 1105 Levee St in October 2025?

Two City of Dallas electrical permits were filed that month. They describe relocating or replacing service equipment and providing power and protection for existing panels and equipment.

What is happening near Thermo 480v Power on Levee Street?

At 1105 Levee St, City of Dallas permits indicate upgrades to the building’s electrical service and distribution equipment. The latest permit was filed August 14, 2026.

Also being built nearby

All of 75207

More warehouses & industrial in 75207.

Get alerts for 1105 Levee St